Relative humidity and temperature control is key in museums, galleries, libraries and archives. Normally constant volume (CV) air handling units (AHUs) with reheat coils are applied in these buildings. Setting a low supply air temperature limits the highest humidity level; however, reheat coils have to be used to maintain space temperature due to constant supply airflow. As a result, simultaneous heating and cooling exists with excessive energy consumption. It is well known that variable air volume (VAV) technologies can reduce simultaneous heating and cooling as well as fan power. This paper presents the detail VAV system retrofit for the existing CV system, control sequence development and system performance evaluation in a museum facility at Omaha, Nebraska. Variable Frequency Drives (VFDs) were installed for the supply fan on the AHUs. Space humidity and temperature, heating and cooling energy consumption, and fan power were measured. The measurements showed that the space humidity and temperature was maintained within the required range under VAV operation while the reheat consumption was reduced by up to 85% and the fan power consumption was reduced by 90% under partial cooling loads.
引用
下载
收藏
页码:451 / 456
页数:6
相关论文
共 50 条
  • [1] Discussion on the Application of Variable-air-volume Air-conditioning System on Ships
    Guo, Junjie
    Chen, Wu
    Cai, Zhenxiong
    Zheng, Chaoyu
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 413 - 418
  • [2] APPLICATION OF DIRECT DIGITAL-CONTROL TO A VARIABLE AIR VOLUME SYSTEM
    WALKER, CA
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1984, 26 (05): : 59 - 59
  • [3] Staged variable air volume air-conditioning system and its application in stores
    Zhao, JN
    Guo, J
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 1247 - 1253
  • [4] ROOM AIR DISTRIBUTION WITH A VARIABLE AIR VOLUME SYSTEM
    STRAUB, HE
    ASHRAE JOURNAL, 1969, 11 (06): : 69 - &
  • [5] Pressure controlled variable air volume system
    Engdahl, F
    Svensson, A
    ENERGY AND BUILDINGS, 2003, 35 (11) : 1161 - 1172
  • [6] ROOM AIR DISTRIBUTION WITH A VARIABLE VOLUME SYSTEM
    STRAUB, HE
    ASHRAE JOURNAL, 1970, 12 (04): : 52 - &
  • [7] Energy efficient fuzzy based combined variable refrigerant volume and variable air volume air conditioning system for buildings
    Karunakaran, R.
    Iniyan, S.
    Goic, Ranko
    APPLIED ENERGY, 2010, 87 (04) : 1158 - 1175
  • [8] Optimal control of variable air volume air-conditioning system
    Chen, You-Ming
    Liu, Jian
    Cheng, Shi-Bai
    Chan, Wing-Hong
    Qin, Jian-Ying
    Zhou, Qiang
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2013, 40 (06): : 1 - 6
  • [9] Characterizing variations in variable air volume system controls
    Pang, Xiufeng
    Piette, Mary A.
    Zhou, Nan
    ENERGY AND BUILDINGS, 2017, 135 : 166 - 175
  • [10] Cascade control for supply air temperature in a variable air volume system
    Zhuang, Junhua
    Chen, Yimin
    Wu, Jie
    4TH ASIA CONFERENCE OF INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2019, 238