Comparison between pulse waveform analysis and thermodilution cardiac output determination in patients with severe pre-eclampsia

被引:29
|
作者
Dyer, R. A. [1 ]
Piercy, J. L. [1 ,2 ]
Reed, A. R. [1 ]
Strathie, G. W. [2 ]
Lombard, C. J. [5 ]
Anthony, J. A. [3 ,4 ]
James, M. F. [1 ]
机构
[1] Univ Cape Town, Dept Anaesthesia D23, ZA-7925 Cape Town, South Africa
[2] Univ Cape Town, Dept Crit Care, ZA-7925 Cape Town, South Africa
[3] Univ Cape Town, Dept Obstet & Gynaecol, ZA-7925 Cape Town, South Africa
[4] Groote Schuur Hosp, ZA-7925 Cape Town, South Africa
[5] MRC, Biostat Unit, Cape Town, South Africa
关键词
cardiac output; monitoring; pre-eclampsia; INJECTION; AGREEMENT; PRECISION; PRESSURE;
D O I
10.1093/bja/aeq292
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. This study compared cardiac output (CO) measurements derived from pulse waveform analysis with values obtained by thermodilution (TD), in patients with postpartum complications of severe pre-eclampsia. Methods. Eighteen patients were recruited, 24-96 h post-delivery. After central venous calibration of the pulse waveform analysis monitor (LiDCOplus), CO readings were compared with those obtained by the TD method and repeated twice at 15 min intervals. The comparison was repeated after peripheral venous calibration. Further comparisons were made in eight patients at 120 and 240 min after peripheral venous calibration. Results. Data were pooled for measurements at 0, 15, and 30 min after calibration. For the comparison between TD and LiDCOplus using central venous calibration, TD exhibited a significant positive bias of 0.58 litre min(-1) [95% confidence interval (CI): 0.77 to 0.39]. After peripheral venous calibration, there was no significant bias [0.16 litre min(-1) (95% CI: -0.37 to 0.06)]. The estimated limits of agreement for central and peripheral venous calibrations were -2.12 to 0.96 and -1.50 to 1.20 litre min(-1), respectively. When comparing LiDCOplus and TD, there was no time-based effect at 120 or 240 min post-peripheral calibration. Conclusions. Central and peripheral venous calibrations of the LiDCOplus monitor were associated with clinically insignificant bias when compared with TD. Limits of agreement were within the recommendation of 30% for acceptance of a new CO technique when compared with current reference methods. This form of minimally invasive CO monitoring may have a valuable role in obstetric critical care.
引用
收藏
页码:77 / 81
页数:5
相关论文
共 50 条
  • [41] Comparison between continuous noninvasive estimated cardiac output by pulse wave transit time and thermodilution method
    Mehta, Yatin
    ANNALS OF CARDIAC ANAESTHESIA, 2014, 17 (04) : 278 - 278
  • [42] Arterial pulse cardiac output agreement with thermodilution in patients in hyperdynamic conditions
    Della Rocca, Giorgio
    Costa, Maria Gabriella
    Chiarandini, Paolo
    Bertossi, Gaia
    Lugano, Manuela
    Pompei, Livia
    Coccia, Cecilia
    Sainz-Barriga, Mauricio
    Pietropaoli, Paolo
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2008, 22 (05) : 681 - 687
  • [43] EARLY-ONSET PRE-ECLAMPSIA PREDICTION AND PULSE WAVE ANALYSIS
    Lan, P.
    Hyett, J.
    Gillin, A.
    NEPHROLOGY, 2014, 19 : 53 - 53
  • [44] Comparison between measurements of cardiac output by thermodilution method and pulse dye densitometry using indocyanine green
    Watanabe, Y
    Takeda, A
    Hirakawa, M
    CRITICAL CARE MEDICINE, 1999, 27 (01) : A117 - A117
  • [45] Comparison of cardiac output values; pulse contour methods against thermodilution technique
    R De Wilde
    B Geerts
    P Van den Berg
    J Jansen
    Critical Care, 14 (Suppl 1):
  • [46] REPLY: Understanding the Complex Link Between Cardiac Function and Pre-Eclampsia
    Vaught, Arthur Jason
    Kovell, Lara C.
    Ouyang, Pamela
    Mukherjee, Monica
    Zakaria, Sammy
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (20) : 2544 - 2545
  • [47] A comparison of the use of transoesophageal Doppler and thermodilution techniques for cardiac output determination
    Keyl, C
    Rodig, G
    Lemberger, P
    Hobbhahn, J
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1996, 13 (02) : 136 - 142
  • [48] CARDIAC OUTPUT MEASUREMENTS WITH AN UNCALIBRATED PULSE CONTOUR METHOD IN CRITICALLY ILL PATIENTS: COMPARISON WITH THERMODILUTION AND ECHOCARDIOGRAPHY
    Scolletta, Sabino
    Bodson, Laurent
    Donadello, Katia
    Devigili, Alessandro
    Taccone, Fabio Silvio
    Herpain, Antoine
    Vincent, Jean-Louis
    De Backer, Daniel
    CRITICAL CARE MEDICINE, 2010, 38 (12) : U64 - U64
  • [49] Decreased expression of apelin in placentas from severe pre-eclampsia patients
    Inuzuka, Hiromi
    Nishizawa, Haruki
    Inagaki, Ayaka
    Suzuki, Machiko
    Ota, Sayuri
    Miyamura, Hironori
    Miyazaki, Jun
    Sekiya, Takao
    Kurahashi, Hiroki
    Udagawa, Yasuhiro
    HYPERTENSION IN PREGNANCY, 2013, 32 (04) : 410 - 421
  • [50] Upregulation of HtrA4 in the placentas of patients with severe pre-eclampsia
    Inagaki, A.
    Nishizawa, H.
    Ota, S.
    Suzuki, M.
    Inuzuka, H.
    Miyamura, H.
    Sekiya, T.
    Kurahashi, H.
    Udagawa, Y.
    PLACENTA, 2012, 33 (11) : 919 - 926