Comparison between pulse waveform analysis and thermodilution cardiac output determination in patients with severe pre-eclampsia

被引:29
|
作者
Dyer, R. A. [1 ]
Piercy, J. L. [1 ,2 ]
Reed, A. R. [1 ]
Strathie, G. W. [2 ]
Lombard, C. J. [5 ]
Anthony, J. A. [3 ,4 ]
James, M. F. [1 ]
机构
[1] Univ Cape Town, Dept Anaesthesia D23, ZA-7925 Cape Town, South Africa
[2] Univ Cape Town, Dept Crit Care, ZA-7925 Cape Town, South Africa
[3] Univ Cape Town, Dept Obstet & Gynaecol, ZA-7925 Cape Town, South Africa
[4] Groote Schuur Hosp, ZA-7925 Cape Town, South Africa
[5] MRC, Biostat Unit, Cape Town, South Africa
关键词
cardiac output; monitoring; pre-eclampsia; INJECTION; AGREEMENT; PRECISION; PRESSURE;
D O I
10.1093/bja/aeq292
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. This study compared cardiac output (CO) measurements derived from pulse waveform analysis with values obtained by thermodilution (TD), in patients with postpartum complications of severe pre-eclampsia. Methods. Eighteen patients were recruited, 24-96 h post-delivery. After central venous calibration of the pulse waveform analysis monitor (LiDCOplus), CO readings were compared with those obtained by the TD method and repeated twice at 15 min intervals. The comparison was repeated after peripheral venous calibration. Further comparisons were made in eight patients at 120 and 240 min after peripheral venous calibration. Results. Data were pooled for measurements at 0, 15, and 30 min after calibration. For the comparison between TD and LiDCOplus using central venous calibration, TD exhibited a significant positive bias of 0.58 litre min(-1) [95% confidence interval (CI): 0.77 to 0.39]. After peripheral venous calibration, there was no significant bias [0.16 litre min(-1) (95% CI: -0.37 to 0.06)]. The estimated limits of agreement for central and peripheral venous calibrations were -2.12 to 0.96 and -1.50 to 1.20 litre min(-1), respectively. When comparing LiDCOplus and TD, there was no time-based effect at 120 or 240 min post-peripheral calibration. Conclusions. Central and peripheral venous calibrations of the LiDCOplus monitor were associated with clinically insignificant bias when compared with TD. Limits of agreement were within the recommendation of 30% for acceptance of a new CO technique when compared with current reference methods. This form of minimally invasive CO monitoring may have a valuable role in obstetric critical care.
引用
收藏
页码:77 / 81
页数:5
相关论文
共 50 条
  • [31] COMPARISON OF THERMODILUTION AND PULSE DOPPLER METHODS FOR MEASURING CARDIAC-OUTPUT IN CRITICALLY ILL PATIENTS
    DONOVAN, KD
    DOBB, G
    LEE, K
    NEWMAN, M
    IRELAND, M
    HOCKINGS, B
    ANAESTHESIA AND INTENSIVE CARE, 1985, 13 (02) : 201 - 202
  • [32] Comparison of impedance cardiography to thermodilution cardiac output determination in pediatric heart transplant patients
    Das, B. B.
    Doyle, S.
    Baker, L.
    Smith, C.
    Recto, M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (02): : S242 - S242
  • [33] Accuracy of Cardiac Output by Nine Different Pulse Contour Algorithms in Cardiac Surgery Patients: A Comparison with Transpulmonary Thermodilution
    Broch, Ole
    Bein, Berthold
    Gruenewald, Matthias
    Masing, Sarah
    Huenges, Katharina
    Haneya, Assad
    Steinfath, Markus
    Renner, Jochen
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [34] Exploring sub-phenotypes in patients with severe pre-eclampsia: a latent class analysis
    Rojas, J.
    Anichiarico, W.
    Burwick, R.
    Santacruz, J.
    Valencia, C. M.
    Velasquez, J.
    Cardona, A.
    Bello, C.
    Escobar, M.
    Alfieri, N.
    Lopez Pautt, A.
    Velasquez, P.
    Miranda, J.
    Tolosa, J. E.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2023, 62 : 214 - 214
  • [35] Comparison of the Endotracheal Cardiac Output Monitor to Thermodilution in Cardiac Surgery Patients
    Ball, Timothy R.
    Culp, Benjamin C.
    Patel, Vivekkumar
    Gloyna, David F.
    Ciceri, David P.
    Culp, William C., Jr.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2010, 24 (05) : 762 - 766
  • [36] Continuous cardiac output measurement:: pulse contour analysis vs thermodilution technique in cardiac surgical patients
    Rödig, G
    Prasser, C
    Keyl, C
    Liebold, A
    Hobbhahn, J
    BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 (04) : 525 - 530
  • [37] Association between an abnormal cerebroplacental ratio and the development of severe pre-eclampsia
    Regan, Jodi
    Masters, Heather
    Warshak, Carri
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2014, 210 (01) : S164 - S165
  • [38] Association between an abnormal cerebroplacental ratio and the development of severe pre-eclampsia
    Regan, J.
    Masters, H.
    Warshak, C. R.
    JOURNAL OF PERINATOLOGY, 2015, 35 (05) : 322 - 327
  • [39] Association between an abnormal cerebroplacental ratio and the development of severe pre-eclampsia
    J Regan
    H Masters
    C R Warshak
    Journal of Perinatology, 2015, 35 : 322 - 327