Ionization chamber dosimetry of small photon fields:: a Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams

被引:0
|
作者
Sánchez-Doblado, F
Andreo, P
Capote, R
Leal, A
Perucha, M
Arráns, R
Núñez, L
Mainegra, E
Lagares, JI
Carrasco, E
机构
[1] Hosp Univ Virgen Macarena, E-41009 Seville, Spain
[2] Univ Seville, Dipartimento Fis Med & Biofis, Seville, Spain
[3] Univ Stockholm, Karolinska Inst, Div Med Radiat Phys, SE-17176 Stockholm, Sweden
[4] Clin Puerta Hierro, Madrid, Spain
[5] Natl Res Council Canada, Ottawa, ON, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2003年 / 48卷 / 14期
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Absolute dosimetry with ionization chambers of the narrow photon fields used in stereotactic techniques and IMRT beamlets is constrained by lack of electron equilibrium in the radiation field. It is questionable that stopping-power ratio in dosimetry protocols, obtained for broad photon beams and quasi-electron equilibrium conditions, can be used in the dosimetry of narrow fields while keeping the uncertainty at the game level as for the broad beams used in accelerator calibrations. Monte Carlo simulations have been performed for two 6 MV clinical accelerators (Elekta SL-18 and Siemens Mevatron Primus), equipped with radiosurgery applicators and MLC. Narrow circular and Z-shaped on-axis and off-axis fields, as well as broad IMRT configured beams, have been simulated together with reference 10 x 10 cm(2) beams. Phase-space data have been used to generate 3D dose distributions which have been compared satisfactorily with experimental profiles (ion chamber, diodes and film). Photon and electron spectra at various depths in water have been calculated, followed by Spencer-Attix (Delta = 10 keV) stopping-power ratio calculations which have been compared to those used in the IAEA TRS-398 code of practice. For water/air and PMMA/air stopping-power ratios, agreements within 0.1% have been obtained for the 10 x 10 cm2 fields. For radiosurgery applicators and narrow MLC beams, the calculated s(w,air) values agree with the reference within +/-0.3%, well within the estimated standard uncertainty of the reference stopping-power ratios (0.5%). Ionization chamber dosimetry of narrow beams at the photon qualities used in this work (6 MV) can therefore be based on stopping-power ratios data in dosimetry protocols. For a modulated 6 MV broad beam used in clinical IMRT, s(w,air) agrees within 0.1% with the value for 10 x 10 cm(2) confirming that at low energies IMRT absolute dosimetry can also be based on data for open reference fields. At higher energies (24 MV) the difference in s(w,air) was up to 1.1%, indicating that the use of protocol data for narrow beams in such cases is less accurate than at low energies, and detailed calculations of the dosimetry parameters involved should be performed if similar accuracy to that of 6 MV is sought.
引用
下载
收藏
页码:2081 / 2099
页数:19
相关论文
共 50 条
  • [41] Dosimetry study of 6-MV X-ray beams in stereotactic radiosurgery with BEAM/EGSnrc Monte Carlo code
    Wysocka, A
    Rostkowska, J
    Kania, M
    Bulski, W
    INTERNATIONAL JOURNAL OF CANCER, 2002, : 456 - 456
  • [42] Dosimetric characterization of PTW MicroDiamond for FFF beams and small fields: experimental and Monte Carlo study
    Stravato, A.
    Reggiori, G.
    Pimpinella, M.
    Lobefalo, F.
    Cozzi, L.
    Fogliata, A.
    Gaudino, A.
    Mancosu, P.
    Palumbo, V.
    Scorsetti, M.
    Tomatis, S.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S417 - S418
  • [43] Monte Carlo calculated output correction factors for Gafchromic EBT3 film for relative dosimetry in small stereotactic radiosurgery fields
    Morales, Johnny E.
    Butson, Martin
    Hill, Robin
    Crowe, Scott B.
    Trapp, J., V
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (02) : 609 - 616
  • [44] Monte Carlo calculated output correction factors for Gafchromic EBT3 film for relative dosimetry in small stereotactic radiosurgery fields
    Johnny E. Morales
    Martin Butson
    Robin Hill
    Scott B. Crowe
    J. V. Trapp
    Physical and Engineering Sciences in Medicine, 2020, 43 : 609 - 616
  • [45] Bone and mucosal dosimetry in skin radiation therapy: a Monte Carlo study using kilovoltage photon and megavoltage electron beams
    Chow, James C. L.
    Jiang, Runqing
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (12): : 3885 - 3899
  • [46] Positioning Recommendations for Parallel-Plate Ionization Chambers in Clinical Electron Beams According to Different Dosimetry Protocols - a Monte Carlo Study for Three Different Chamber Types
    Zink, K.
    Altintas, S.
    Poppe, B.
    Wulff, J.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [47] Roos and NACP-02 ion chamber perturbations and water-air stopping-power ratios for clinical electron beams for energies from 4 to 22 MeV
    Bailey, M.
    Shipley, D. R.
    Manning, J. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (03): : 1087 - 1105
  • [48] Dosimetry of small photon fields in the presence of bone heterogeneity using MAGIC polymer gel, Gafchromic film, and Monte Carlo simulation
    Parwaie, Wrya
    Geraily, Ghazale
    Mehri-Kakavand, Ghazal
    Babaloui, Somayyeh
    Rezvani, Samira
    Pursamimi, Mohamad
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2022, 27 (02) : 226 - 234
  • [49] Monte Carlo study on mucosal dose in oral and nasal cavity using photon beams with small field
    Chow, James C. L.
    Owrangi, Amir M.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2010, 10 (04) : 261 - 271
  • [50] Monte Carlo study on electron contamination and output factors of small field dosimetry in 6 MV photon beam
    Yani, Sitti
    Dirgayussa, I. Gde Eka
    Rhani, Mohamad Fahdillah
    Soh, Roger C. X.
    Haryanto, Freddy
    Arif, Idam
    SMART SCIENCE, 2016, 4 (02): : 87 - 94