Monte Carlo calculated output correction factors for Gafchromic EBT3 film for relative dosimetry in small stereotactic radiosurgery fields

被引:8
|
作者
Morales, Johnny E. [1 ,2 ]
Butson, Martin [1 ,3 ]
Hill, Robin [1 ,3 ]
Crowe, Scott B. [2 ,4 ]
Trapp, J., V [2 ]
机构
[1] Chris OBrien Lifehouse, Dept Radiat Oncol, 119-143 Missenden Rd, Camperdown, NSW 2050, Australia
[2] Queensland Univ Technol, Sch Chem Phys & Mech Engn, Level 4 O Block, Gardens Point, Qld 4001, Australia
[3] Univ Sydney, Sch Phys, Inst Med Phys, Sydney, NSW 2006, Australia
[4] Royal Brisbane & Womens Hosp, Canc Care Serv, Butterfield St, Herston, Qld 4029, Australia
关键词
Gafchromic EBT3; Monte Carlo; Small field dosimetry; TRS-483; SRS; Brainlab; TECHNICAL NOTE; RADIOCHROMIC FILM; ENERGY-DEPENDENCE; SMALL MV; BEAMS;
D O I
10.1007/s13246-020-00860-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To calculate small field output correction factors, k fclin,fmsr Qclin,Qmsr, for Gafchromic EBT3 film using Monte Carlo simulations. These factors were determined for a Novalis Trilogy linear accelerator equipped with Brainlab circular cones with diameters of 4.0 to 30.0 mm. The BEAMnrc Monte Carlo code was used to simulate the Novalis Trilogy linear accelerator and the Brainlab cones with diameters 4.0 to 30 mm. The DOSXYZnrc code was used to simulate Gafchromic EBT3 film with the atomic composition specified by the manufacturer. Small field correction factors were calculated according to new IAEA TRS-483 Code of Practice for small field dosimetry. The depth of calculation was 10 cm and a source to surface distance of 100 cm. The X-ray beam used in the simulations was a 6 MV SRS. The correction factors were then used to determine field output factors with Gafchromic EBT3 film. These field output factors were validated using three solid state detectors and applying correction factors from the TRS-483 Code of Practice. The solid state detectors were IBA SFD diode, PTW 60018 SRS diode and PTW 60019 microDiamond. The Monte Carlo calculated output correction factors, kfclin,fmsr Qclin,Qmsr, for Gafchromic EBT3 film ranged between 0.998 to 1.004 for Brainlab circular cones with diameters between 4.0 and 30.0 mm. The uncertainty for these factors was 2.0%. The field output factors obtained with Gafchromic EBT3 film were within 2% of the mean results obtained with the three solid state detectors. For field sizes 4 mm diameter and above, Gafchromic EBT3 film has field output correction factors within 1% of unity. Therefore, Gafchromic EBT3 film can be considered to be correction less and supports the assumption made about this film in the TRS-483 Code of Practice.
引用
收藏
页码:609 / 616
页数:8
相关论文
共 50 条
  • [1] Monte Carlo calculated output correction factors for Gafchromic EBT3 film for relative dosimetry in small stereotactic radiosurgery fields
    Johnny E. Morales
    Martin Butson
    Robin Hill
    Scott B. Crowe
    J. V. Trapp
    [J]. Physical and Engineering Sciences in Medicine, 2020, 43 : 609 - 616
  • [2] Gafchromic EBT3 film provides equivalent dosimetric performance to EBT-XD film for stereotactic radiosurgery dosimetry
    Smyth, Lloyd
    Alves, Andrew
    Collins, Katherine
    Beveridge, Sabeena
    [J]. PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (03) : 1095 - 1106
  • [3] A characterisation of EBT3 Gafchromic film for relative and absolute dosimetry
    Billas, I.
    Bouchard, H.
    Subiel, A.
    Silvestre, I.
    Duane, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S414 - S414
  • [4] Absolute Film Dosimetry for Stereotactic Radiosurgery and Stereotactic Body Radiotherapy Quality Assurance Using Gafchromic EBT3 Films
    Wen, N.
    Lu, S.
    Qin, Y.
    Huang, Y.
    Zhao, B.
    Liu, C.
    Chetty, I.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3593 - 3593
  • [5] Precise film dosimetry for stereotactic radiosurgery and stereotactic body radiotherapy quality assurance using Gafchromic™ EBT3 films
    Ning Wen
    Siming Lu
    Jinkoo Kim
    Yujiao Qin
    Yimei Huang
    Bo Zhao
    Chang Liu
    Indrin J. Chetty
    [J]. Radiation Oncology, 11
  • [6] Precise film dosimetry for stereotactic radiosurgery and stereotactic body radiotherapy quality assurance using Gafchromic™ EBT3 films
    Wen, Ning
    Lu, Siming
    Kim, Jinkoo
    Qin, Yujiao
    Huang, Yimei
    Zhao, Bo
    Liu, Chang
    Chetty, Indrin J.
    [J]. RADIATION ONCOLOGY, 2016, 11
  • [7] Small field output factors measurement with EBT3 gafchromic film in water
    Obesso, A.
    Ferrer, C.
    Huertas, C.
    Corredoira, E.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S698 - S699
  • [8] Extrapolation Techniques for Small Field Dosimetry Using Gafchromic EBT3 Film
    Morales, J.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3596 - 3596
  • [9] Precise EBT3 Gafchromic film dosimetry for Grid therapy
    Gholami, Somayeh
    Nedaie, Hassan Ali
    Meigooni, Ali S.
    [J]. RADIATION MEASUREMENTS, 2019, 121 : 69 - 76
  • [10] A Study of Surface Dosimetry for Whole Breast Irradiation Geometry Using EBT3 Gafchromic Film and Monte Carlo Simulation
    Su, S.
    Carpentier, E.
    Duzenli, C.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)