Renal artery stenosis: Value of screening with three-dimensional phase-contrast MR angiography with a phased-array multicoil

被引:38
|
作者
DeCobelli, F [1 ]
Mellone, R [1 ]
Salvioni, M [1 ]
Vanzulli, A [1 ]
Sironi, S [1 ]
Manunta, P [1 ]
Lanzani, C [1 ]
Bianchi, G [1 ]
DelMaschio, A [1 ]
机构
[1] UNIV HOSP, SCI INST H S RAFFAELE, DEPT NEPHROL, I-20132 MILAN, ITALY
关键词
D O I
10.1148/radiology.201.3.8939218
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate screening with three-dimensional (3D) phase-contrast magnetic resonance (MR) angiography with a phased-array multicoil to detect renal artery stenosis. MATERIALS AND METHODS: Fifty consecutive patients suspected of having renovascular disease were prospectively examined with 3D phase-contrast MR imaging with a phased-array multicoil. Findings were correlated with those at intraarterial digital subtraction angiography (DSA) as the standard of reference for grade of stenosis. RESULTS: MR angiography depicted 101 of 103 renal arteries depicted at intraarterial DSA; the two missed arteries were an accessory artery outside the imaging volume and an artery with a stent. At intraarterial DSA, a stenosis was found in 31 of 101 arteries. On the basis of findings at 3D phase-contrast MR angiography, the presence of any degree of stenosis was correctly depicted in 29 of 31 cases and the absence of stenosis was correctly depicted in 66 of 70 cases (accuracy, 94%; sensitivity, 94%; negative predictive value, 97%). Overall accuracy was 97% for correct depiction of severe renal artery stenosis (>50%). CONCLUSION: 3D phase-contrast MR angiography with a phased-array multicoil was an accurate noninvasive screening technique in patients with suspected renal artery stenosis.
引用
收藏
页码:697 / 703
页数:7
相关论文
共 50 条
  • [1] Evaluation of renal artery stenosis with 3D phase-contrast MR angiography and phased-array multicoil
    DeCobelli, F
    Mellone, R
    Vanzulli, A
    Sironi, S
    Salvioni, M
    DelMaschio, A
    RADIOLOGY, 1996, 201 : 1340 - 1340
  • [2] MR angiography of renal artery stenosis: Value of the combination of three-dimensional time-of-flight and three-dimensional phase-contrast MR angiography sequences
    Loubeyre, P
    Trolliet, P
    Cahen, R
    Grozel, F
    Labeeuw, M
    Minh, VAT
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) : 489 - 494
  • [3] RECONSTRUCTIONS OF PHASE-CONTRAST, PHASED-ARRAY MULTICOIL DATA
    BERNSTEIN, MA
    GRGIC, M
    BROSNAN, TJ
    PELC, NJ
    MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) : 330 - 334
  • [4] Hemodynamic significance of renal artery stenosis: Digital subtraction angiography versus systolically gated three-dimensional phase-contrast MR angiography
    Wasser, MN
    Westenberg, J
    vanderHulst, VPM
    vanBaalen, J
    vanBockel, H
    vanErkel, AR
    Pattynama, PMT
    RADIOLOGY, 1997, 202 (02) : 333 - 338
  • [5] Phase-contrast MR angiography for detection of arteriosclerotic renal artery stenosis
    Duda, SH
    Schick, F
    Teufl, F
    MullerSchimpfle, M
    Erley, C
    Schneider, W
    Miller, S
    Claussen, CD
    ACTA RADIOLOGICA, 1997, 38 (02) : 287 - 291
  • [6] Renal artery stenosis: Evaluation with breath-hold, three-dimensional, dynamic, gadolinium-enhanced versus three-dimensional, phase-contrast MR angiography
    DeCobelli, F
    Vanzulli, A
    Sironi, S
    Mellone, R
    Angeli, E
    Venturini, M
    Garancini, MP
    Quartagno, R
    Bianchi, G
    DelMaschio, A
    RADIOLOGY, 1997, 205 (03) : 689 - 695
  • [7] Detection of main renal artery stenosis using phase-contrast cine MR angiography
    Silverman, JM
    Friedman, MI
    VanAllan, RJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (05) : 1131 - 1137
  • [8] Three-dimensional spiral CT angiography in renal artery stenosis
    Inoue, T
    Asahi, S
    Tanaka, K
    Sakai, Y
    Morooka, S
    JOURNAL OF CARDIOVASCULAR DIAGNOSIS AND PROCEDURES, 1998, 15 (01): : 55 - 58
  • [9] MR angiography of the renal artery: comparison of breath-hold two-dimensional phase-contrast cine technique with the phased-array coil and breath-hold two-dimensional time-of-flight technique with the body coil
    Masui, T
    Takehara, Y
    Igarashi, T
    Ichijo, K
    Takahashi, M
    Kaneko, M
    Nozaki, A
    EUROPEAN JOURNAL OF RADIOLOGY, 1997, 25 (01) : 62 - 66
  • [10] Three-dimensional phase-contrast magnetic resonance angiography: A useful clinical adjunct to gadolinium-enhanced three-dimensional renal magnetic resonance angiography?
    Hood, MN
    Ho, VB
    Corse, WR
    MILITARY MEDICINE, 2002, 167 (04) : 343 - 349