Phase-contrast MR angiography for detection of arteriosclerotic renal artery stenosis

被引:2
|
作者
Duda, SH
Schick, F
Teufl, F
MullerSchimpfle, M
Erley, C
Schneider, W
Miller, S
Claussen, CD
机构
[1] UNIV TUBINGEN,DEPT INTERNAL MED 3,D-72076 TUBINGEN,GERMANY
[2] UNIV TUBINGEN,DEPT CARDIOVASC & THORAC SURG,D-72076 TUBINGEN,GERMANY
关键词
renal arteries; stenosis or obstruction; MR; pulse sequences; phase imaging;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the accuracy of 3-D phase-contrast (PC) MR imaging with a 2-D time-of-flight (TOF) technique in the detection of arteriosclerotic renal artery stenosis. Material and Methods: Twenty-two patients with 28 angiographically proven renal artery stenoses were examined in a prospective blinded fashion by using 2-D TOF MR angiography (MRA) with venous saturation (FLASH) and 3-D PC MRA. The renal arteries were subdivided into 3 segments and graded for the presence of stenoses on a scale of 0-4 by 3 radiologists in blind. Results: The accuracy of TOF and PC imaging in detecting renal artery stenoses was 65% and 77% respectively. Both 2-D TOF and 3-D PC MRA depicted 84% of the stenoses of the proximal renal artery greater than 50% in diameter. Renal artery stenoses greater than 50% and more than 15 mm in distance from the aorta were detected in 40% of cases with the 2-D TOF sequence and in 76% with the 3-D PC technique (p<0.05). The rate of false-negative results was 32%. Conclusion: PC MRA is better at visualizing stenoses in the middle segment of the renal arteries and supplements conventional TOF techniques with additional information. However, even when the two techniques are combined, the false-negative rate in the MR imaging of stenoses of the renal arteries still needs to be reduced.
引用
收藏
页码:287 / 291
页数:5
相关论文
共 50 条
  • [1] Detection of main renal artery stenosis using phase-contrast cine MR angiography
    Silverman, JM
    Friedman, MI
    VanAllan, RJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (05) : 1131 - 1137
  • [2] Evaluation of renal artery stenosis with 3D phase-contrast MR angiography and phased-array multicoil
    DeCobelli, F
    Mellone, R
    Vanzulli, A
    Sironi, S
    Salvioni, M
    DelMaschio, A
    RADIOLOGY, 1996, 201 : 1340 - 1340
  • [3] Effect of gadolinium on phase-contrast MR angiography of the renal arteries
    Bass, JC
    Prince, MR
    Londy, FJ
    Chenevert, TL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (01) : 261 - 266
  • [4] Hemodynamic significance of renal artery stenosis: Digital subtraction angiography versus systolically gated three-dimensional phase-contrast MR angiography
    Wasser, MN
    Westenberg, J
    vanderHulst, VPM
    vanBaalen, J
    vanBockel, H
    vanErkel, AR
    Pattynama, PMT
    RADIOLOGY, 1997, 202 (02) : 333 - 338
  • [5] Renal artery stenosis: Value of screening with three-dimensional phase-contrast MR angiography with a phased-array multicoil
    DeCobelli, F
    Mellone, R
    Salvioni, M
    Vanzulli, A
    Sironi, S
    Manunta, P
    Lanzani, C
    Bianchi, G
    DelMaschio, A
    RADIOLOGY, 1996, 201 (03) : 697 - 703
  • [6] Detection of renal artery stenosis using 30 phase contrast MR angiography and dynamic perfusion imaging.
    Miller, S
    Hahn, U
    Schick, F
    Nägele, T
    Duda, SH
    Eckstein, FS
    Scheule, AM
    Claussen, CD
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (02): : 163 - 167
  • [7] Non-contrast MR angiography versus contrast enhanced MR angiography for detection of renal artery stenosis: a comparative analysis in 400 renal arteries
    Lal, Hira
    Singh, Rani Kunti Randhir
    Yadav, Priyank
    Yadav, Ankusha
    Bhadauria, Dharmendra
    Singh, Anuradha
    ABDOMINAL RADIOLOGY, 2021, 46 (05) : 2064 - 2071
  • [8] Non-contrast MR angiography versus contrast enhanced MR angiography for detection of renal artery stenosis: a comparative analysis in 400 renal arteries
    Hira Lal
    Rani Kunti Randhir Singh
    Priyank Yadav
    Ankusha Yadav
    Dharmendra Bhadauria
    Anuradha Singh
    Abdominal Radiology, 2021, 46 : 2064 - 2071
  • [9] MR angiography of renal artery stenosis: Value of the combination of three-dimensional time-of-flight and three-dimensional phase-contrast MR angiography sequences
    Loubeyre, P
    Trolliet, P
    Cahen, R
    Grozel, F
    Labeeuw, M
    Minh, VAT
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) : 489 - 494
  • [10] CAROTID-ARTERY STENOSIS - CLINICAL EFFICACY OF MR PHASE-CONTRAST FLOW QUANTIFICATION AS AN ADJUNCT TO MR-ANGIOGRAPHY
    VANNINEN, RL
    MANNINEN, HI
    PARTANEN, PLK
    VAINIO, PA
    SOIMAKALLIO, S
    RADIOLOGY, 1995, 194 (02) : 459 - 467