Renal artery stenosis: Value of screening with three-dimensional phase-contrast MR angiography with a phased-array multicoil

被引:38
|
作者
DeCobelli, F [1 ]
Mellone, R [1 ]
Salvioni, M [1 ]
Vanzulli, A [1 ]
Sironi, S [1 ]
Manunta, P [1 ]
Lanzani, C [1 ]
Bianchi, G [1 ]
DelMaschio, A [1 ]
机构
[1] UNIV HOSP, SCI INST H S RAFFAELE, DEPT NEPHROL, I-20132 MILAN, ITALY
关键词
D O I
10.1148/radiology.201.3.8939218
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate screening with three-dimensional (3D) phase-contrast magnetic resonance (MR) angiography with a phased-array multicoil to detect renal artery stenosis. MATERIALS AND METHODS: Fifty consecutive patients suspected of having renovascular disease were prospectively examined with 3D phase-contrast MR imaging with a phased-array multicoil. Findings were correlated with those at intraarterial digital subtraction angiography (DSA) as the standard of reference for grade of stenosis. RESULTS: MR angiography depicted 101 of 103 renal arteries depicted at intraarterial DSA; the two missed arteries were an accessory artery outside the imaging volume and an artery with a stent. At intraarterial DSA, a stenosis was found in 31 of 101 arteries. On the basis of findings at 3D phase-contrast MR angiography, the presence of any degree of stenosis was correctly depicted in 29 of 31 cases and the absence of stenosis was correctly depicted in 66 of 70 cases (accuracy, 94%; sensitivity, 94%; negative predictive value, 97%). Overall accuracy was 97% for correct depiction of severe renal artery stenosis (>50%). CONCLUSION: 3D phase-contrast MR angiography with a phased-array multicoil was an accurate noninvasive screening technique in patients with suspected renal artery stenosis.
引用
收藏
页码:697 / 703
页数:7
相关论文
共 50 条
  • [41] Simultaneous Visualization of Vessels and Brain Tumor with Contrast-enhanced Three-dimensional Phase-contrast MR Imaging
    Shigenaga, Yutaka
    Sasaki, Masato
    Ishimoto, Takeshi
    Ama, Keiko
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2018, 17 (02) : 184 - 188
  • [42] Renal Arteries: Isotropic, High-Spatial-Resolution, Unenhanced MR Angiography with Three-dimensional Radial Phase Contrast
    Francois, Christopher J.
    Lum, Darren P.
    Johnson, Kevin M.
    Landgraf, Benjamin R.
    Bley, Thorsten A.
    Reeder, Scott B.
    Schiebler, Mark L.
    Grist, Thomas M.
    Wieben, Oliver
    RADIOLOGY, 2011, 258 (01) : 254 - 260
  • [43] Three-dimensional spiral MR imaging: Application to renal multiphase contrast-enhanced angiography
    Amann, M
    Bock, M
    Floemer, F
    Schoenberg, SO
    Schad, LR
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) : 290 - 296
  • [44] Non-contrast MR angiography versus contrast enhanced MR angiography for detection of renal artery stenosis: a comparative analysis in 400 renal arteries
    Hira Lal
    Rani Kunti Randhir Singh
    Priyank Yadav
    Ankusha Yadav
    Dharmendra Bhadauria
    Anuradha Singh
    Abdominal Radiology, 2021, 46 : 2064 - 2071
  • [45] Non-contrast MR angiography versus contrast enhanced MR angiography for detection of renal artery stenosis: a comparative analysis in 400 renal arteries
    Lal, Hira
    Singh, Rani Kunti Randhir
    Yadav, Priyank
    Yadav, Ankusha
    Bhadauria, Dharmendra
    Singh, Anuradha
    ABDOMINAL RADIOLOGY, 2021, 46 (05) : 2064 - 2071
  • [46] Impact of screening MR angiography on management of patients with suspected renal artery stenosis
    Cay, O
    Chiang, EE
    Rabkin, DJ
    Rosen, MP
    Brophy, DP
    Edelman, RR
    RADIOLOGY, 2000, 217 : 310 - 310
  • [47] Renal cancer: Preoperative evaluation with dual-phase three-dimensional MR angiography
    Choyke, PL
    Walther, MM
    Wagner, JR
    Rayford, W
    Lyne, JC
    Linehan, WM
    RADIOLOGY, 1997, 205 (03) : 767 - 771
  • [48] Three-dimensional phase-contrast imaging of single floating cells
    Kobayashi, Hiroaki
    Ishimaru, Ichirou
    Yasokawa, Toshiki
    Ishizaki, Katsumi
    Kuriyama, Shigeki
    Masaki, Tsutomu
    Nakai, Seiji
    Takegawa, Kaoru
    Tanaka, Naotaka
    APPLIED PHYSICS LETTERS, 2006, 89 (24)
  • [49] Time-resolved three-dimensional phase-contrast MRI
    Markl, M
    Chan, FP
    Alley, MT
    Wedding, KL
    Draney, MT
    Elkins, CJ
    Parker, DW
    Wicker, R
    Taylor, CA
    Herfkens, RJ
    Pelc, NJ
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (04) : 499 - 506
  • [50] Detection of renal artery stenosis using 30 phase contrast MR angiography and dynamic perfusion imaging.
    Miller, S
    Hahn, U
    Schick, F
    Nägele, T
    Duda, SH
    Eckstein, FS
    Scheule, AM
    Claussen, CD
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (02): : 163 - 167