Renal artery stenosis: Value of screening with three-dimensional phase-contrast MR angiography with a phased-array multicoil

被引:38
|
作者
DeCobelli, F [1 ]
Mellone, R [1 ]
Salvioni, M [1 ]
Vanzulli, A [1 ]
Sironi, S [1 ]
Manunta, P [1 ]
Lanzani, C [1 ]
Bianchi, G [1 ]
DelMaschio, A [1 ]
机构
[1] UNIV HOSP, SCI INST H S RAFFAELE, DEPT NEPHROL, I-20132 MILAN, ITALY
关键词
D O I
10.1148/radiology.201.3.8939218
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate screening with three-dimensional (3D) phase-contrast magnetic resonance (MR) angiography with a phased-array multicoil to detect renal artery stenosis. MATERIALS AND METHODS: Fifty consecutive patients suspected of having renovascular disease were prospectively examined with 3D phase-contrast MR imaging with a phased-array multicoil. Findings were correlated with those at intraarterial digital subtraction angiography (DSA) as the standard of reference for grade of stenosis. RESULTS: MR angiography depicted 101 of 103 renal arteries depicted at intraarterial DSA; the two missed arteries were an accessory artery outside the imaging volume and an artery with a stent. At intraarterial DSA, a stenosis was found in 31 of 101 arteries. On the basis of findings at 3D phase-contrast MR angiography, the presence of any degree of stenosis was correctly depicted in 29 of 31 cases and the absence of stenosis was correctly depicted in 66 of 70 cases (accuracy, 94%; sensitivity, 94%; negative predictive value, 97%). Overall accuracy was 97% for correct depiction of severe renal artery stenosis (>50%). CONCLUSION: 3D phase-contrast MR angiography with a phased-array multicoil was an accurate noninvasive screening technique in patients with suspected renal artery stenosis.
引用
收藏
页码:697 / 703
页数:7
相关论文
共 50 条
  • [21] Assessment of renal artery stenosis with triple-dose gadolinium-enhanced 3D phase-contrast MR angiography
    Miller, S
    Schick, F
    Duda, SH
    Naegele, T
    Albes, J
    Erley, C
    RADIOLOGY, 1996, 201 : 1344 - 1344
  • [22] GD-enhanced 3D phase-contrast MR angiography and dynamic perfusion imaging in the diagnosis of renal artery stenosis
    Miller, S
    Schick, F
    Duda, SH
    Nägele, T
    Hahn, U
    Teufl, F
    Müller-Schimpfle, M
    Erley, CM
    Albes, JM
    Claussen, CD
    MAGNETIC RESONANCE IMAGING, 1998, 16 (09) : 1005 - 1012
  • [23] Design and Implementation of mmWave Phased-array Radar for Three-dimensional Imaging
    Li, Jiawang
    Hong, Wei
    Hu, Yun
    Liu, Huimin
    Xu, Gang
    Zhu, Yuanwei
    Zhang, Zongyu
    Pan, Zhenyu
    2022 INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY (ICMMT), 2022,
  • [24] Evaluation of renal artery stenosis by 3D gadolinium angiography and phase-contrast flow measurements
    Schoenberg, SO
    Knopp, MV
    Bock, M
    Essig, M
    Hawighorst, H
    Allenberg, JR
    RADIOLOGY, 1997, 205 : 473 - 473
  • [25] Time Course of Vascular Reactivity Using Repeated Phase-Contrast MR Angiography in Patients With Carotid Artery Stenosis
    Hartkamp, Nolan S.
    Hendrikse, Jeroen
    van der Worp, H. Bart
    de Borst, Gert J.
    Bokkers, Reinoud P. H.
    STROKE, 2012, 43 (02) : 553 - 556
  • [26] Contrast-enhanced three-dimensional MR angiography in the assessment of subclavian artery diseases
    M. Cosottini
    V. Zampa
    P. Petruzzi
    S. Ortori
    R. Cioni
    C. Bartolozzi
    European Radiology, 2000, 10 : 1737 - 1744
  • [27] Contrast-enhanced three-dimensional MR angiography in the assessment of subclavian artery diseases
    Cosottini, M
    Zampa, V
    Petruzzi, P
    Ortori, S
    Cioni, R
    Bartolozzi, C
    EUROPEAN RADIOLOGY, 2000, 10 (11) : 1737 - 1744
  • [28] Three-dimensional contrast-enhanced MR angiography and phase contrast flow analysis for internal mammary artery graft evaluation
    Liu, Y
    Breger, RK
    Kumar, B
    Blechinger, J
    Desai, PB
    Tector, A
    RADIOLOGY, 1999, 213P : 436 - 436
  • [29] Renal artery stenosis: Grading of hemodynamic changes with cine phase-contrast MR blood flow measurements
    Schoenberg, SO
    Knopp, MV
    Bock, M
    Kallinowski, F
    Just, A
    Essig, M
    Hawighorst, H
    Schad, L
    vanKaick, G
    RADIOLOGY, 1997, 203 (01) : 45 - 53
  • [30] Assessment of hemodynamic changes in patients with renal artery stenosis by means of the cine MR phase-contrast technique
    S. O. Schoenberg
    M. V. Knopp
    M. Bock
    F. Kallinowski
    A. Just
    M. Essig
    H. Hawighorst
    I. Zuna
    L. Schad
    J. R. Allenberg
    G. van Kaick
    Der Radiologe, 1997, 37 : 651 - 662