Gamma-Ray Point-Source Detection in Unknown Background Using 3D-Position-Sensitive Semiconductor Detectors

被引:11
|
作者
Wahl, Christopher G. [1 ]
He, Zhong [1 ]
机构
[1] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
关键词
Gamma rays; maximum likelihood detection; radiation detection algorithms; radiation imaging; PORTAL MONITORS; LARGE-AREA; LIKELIHOOD; SOFTWARE;
D O I
10.1109/TNS.2011.2113355
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Three-dimensional-position-sensitive semiconductor detectors provide both energy and locations of gamma-ray interactions in the detector. From these data, Compton-imaging methods can reconstruct the spatial source distribution around the detector as a function of energy. Here, the generalized likelihood ratio test (GLRT) and the source-intensity test (SIT) are applied to automate detection and identification of point sources of radiation in distributed background by using the combined energy and direction information from these detectors. Throughout, the model makes no assumptions of the background intensity or energy distribution. However, directional information enables detection and identification without prior knowledge of the background spectrum and the detection of isotopes also appearing in the background. Spatially, background is modeled as uniform, but only slight degradation in performance was observed when the background was twice as intense in one hemisphere. Experimental detection and identification performance as a function of false-alarm probability was measured for three weak isotopes using experimental data collected on a 20 mm x 20 mm x 15 mm CdZnTe detector. Both the GLRT and SIT performed better than the commercial software Genie 2000 (Canberra), which uses only spectral information, when the possible source direction was unknown. Prior knowledge of the possible source direction further improves both detection and identification.
引用
收藏
页码:605 / 613
页数:9
相关论文
共 50 条
  • [21] Experimental Demonstration of Coded Aperture Imaging using Thick 3D-Position-Sensitive CdZnTe Detectors
    Kaye, Sonal Joshi
    Kaye, William Robert
    He, Zhong
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 1902 - 1906
  • [22] Position-sensitive germanium detectors for gamma-ray imaging and spectroscopy
    Amman, M
    Luke, PN
    HARD X-RAY GAMMA-RAY AND NEUTRON DETECTOR PHYSICS II, 2000, 4141 : 144 - 156
  • [23] Experimental Limitations of Coded Aperture Imaging Using Thick 3D-Position-Sensitive CdZnTe Detectors
    Kaye, Sonal Joshi
    Kaye, Willy Robert
    Jaworski, Jason Michael
    He, Zhong
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3856 - 3859
  • [24] DESIGN AND STATISTICAL PROCEDURES FOR EVALUATION OF AN AUTOMATIC GAMMA-RAY POINT-SOURCE CALIBRATOR
    GARFINKE.SB
    MANN, WB
    YOUDEN, WJ
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS SECTION C-ENGINEERING AND INSTRUMENTATION, 1966, C 70 (02): : 53 - &
  • [25] A 3-DIMENSIONAL POSITION-SENSITIVE GAMMA-RAY DETECTION SYSTEM
    MCINTYRE, JA
    NUCLEAR INSTRUMENTS & METHODS, 1980, 171 (01): : 19 - 27
  • [26] Benefits of Position-Sensitive Detectors for Source Detection with Known Background
    Lingenfelter, Daniel J.
    Fessler, Jeffrey A.
    Scott, Clayton D.
    He, Zhong
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 636 - 640
  • [27] Deepening gamma-ray point-source catalogues with sub-threshold information
    Amerio, Aurelio
    Calore, Francesca
    Serpico, Pasquale Dario
    Zaldivar, Bryan
    JOURNAL OF COSMOLOGY AND ASTROPARTICLE PHYSICS, 2024, (03):
  • [28] Efficient temperature corrections for gamma-ray energy reconstruction in 3-D position-sensitive CdZnTe detectors
    Xia, Jiawei
    Zhu, Yuefeng
    He, Zhong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 954 (954):
  • [29] Measurement of material uniformity using 3-D position sensitive CdZnTe gamma-ray spectrometers
    He, Z
    Li, W
    Knoll, GF
    Wehe, DK
    Stahle, CM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 441 (03): : 459 - 467
  • [30] Analysis of detector response using 3-D position sensitive CZT gamma-ray spectrometers
    Zhang, F
    He, Z
    Xu, D
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3493 - 3497