Amperometric flow injection determination of fructose in honey with a carbon paste sensor based on fructose dehydrogenase

被引:43
|
作者
Parellada, J
Dominguez, E
Fernandez, VM
机构
[1] UNIV ALCALA DE HENARES,FAC FARM,DEPT QUIM ANALIT,E-28871 MADRID,SPAIN
[2] UNIV AUTONOMA MADRID,CSIC,INST CATALISIS,E-28049 MADRID,SPAIN
关键词
fructose; PQQ; fructose dehydrogenase; enzyme electrodes; flow injection analysis; amperometry;
D O I
10.1016/0003-2670(96)87686-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An enzyme carbon paste electrode for quantitation of fructose in a flow injection analysis (FIA) system is developed. The sensor is based on a commercially available pyrrolo quinoline quinone (PQQ)-fructose dehydrogenase. The enzyme is introduced into the carbon paste matrix and addition of polyethyleneimine (PEI) allows an unmediated anodic current to be achieved at 400 mV vs, Ag/AgCl after injections of fructose in the FIA system. Operating at 400 mV, at a flow rate of 1.0 ml min(-1) and with 20 mu l injection volume, the analytical characteristics of the sensor are: limit of detection 75 mu M (S/N 3), linearity up to 10 mM, sensitivity 3 nA mM(-1), complete specificity for fructose and operational stability for 10 h. The biosensor-FIA system has been validated by liquid chromatography-refractive index (LC-RI) for the detection of fructose in honey. Results prove the reliability of the biosensor for the quantitation of fructose in honey samples.
引用
收藏
页码:71 / 77
页数:7
相关论文
共 50 条
  • [21] Ferrocene-mediated carbon paste electrode modified with d-fructose dehydrogenase for batch mode measurement of d-fructose
    Mohamed Boujtita
    Nabil El Murr
    [J]. Applied Biochemistry and Biotechnology, 2000, 89 : 55 - 66
  • [22] A new carbon paste electrode modified with tetrahydroxyanthraquinone: Flow injection amperometric determination of Cr(VI) in water
    Qi, JR
    Li, Z
    Song, WB
    Xu, HD
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (11) : 1455 - 1458
  • [23] A novel amperometric sensor based on intercalated montmorillonite modified carbon paste electrode for hydroquinone determination
    Kong, Yong
    Ma, Mengjie
    Mao, Huihui
    Ma, Jiangquan
    Yao, Chao
    [J]. ANALYTICAL METHODS, 2012, 4 (03) : 748 - 752
  • [24] Flow injection amperometric sensor with a carbon nanotube modified screen printed electrode for determination of hydroquinone
    Upan, Jantima
    Reanpang, Preeyaporn
    Chailapakul, Orawon
    Jakmunee, Jaroon
    [J]. TALANTA, 2016, 146 : 766 - 771
  • [25] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF THIOCYANATE AND SELENOCYANATE AT A COBALT PHTHALOCYANINE MODIFIED CARBON-PASTE ELECTRODE
    COOKEAS, EG
    EFSTATHIOU, CE
    [J]. ANALYST, 1994, 119 (07) : 1607 - 1612
  • [26] Chemically Modified Carbon Paste Electrodes for Ascorbic Acid Determination in Soft Drinks by Flow Injection Amperometric Analysis
    Sales, M. Goreti F.
    Castanheira, M. S. A.
    Ferreira, Rosa M. S.
    Vaz, M. Carmo V. F.
    Delerue-Matos, Cristina
    [J]. PORTUGALIAE ELECTROCHIMICA ACTA, 2008, 26 (01) : 147 - 157
  • [27] A novel palygorskite-modified carbon paste amperometric sensor for catechol determination
    Kong, Yong
    Chen, Xiaohui
    Wang, Wenchang
    Chen, Zhidong
    [J]. ANALYTICA CHIMICA ACTA, 2011, 688 (02) : 203 - 207
  • [28] The role of polypyrrole as charge transfer mediator and immobilization matrix for D-fructose dehydrogenase in a fructose sensor
    Swann, MJ
    Bloor, D
    Haruyama, T
    Aizawa, M
    [J]. BIOSENSORS & BIOELECTRONICS, 1997, 12 (12): : 1169 - 1182
  • [29] Sensitive Determination of Hydroxymethyl Furfural in Honey, Syrup, and Fructose Solution
    Basumallick, Lipika
    Hurum, Deanna
    Rohrer, Jeff
    [J]. LC GC NORTH AMERICA, 2011, : 31 - 31
  • [30] Amperometric sensor for the flow-injection determination of iridium(IV) ions
    Shpigun, LK
    Kopytova, NE
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 52 (12) : 1157 - 1161