Amperometric flow injection determination of fructose in honey with a carbon paste sensor based on fructose dehydrogenase

被引:43
|
作者
Parellada, J
Dominguez, E
Fernandez, VM
机构
[1] UNIV ALCALA DE HENARES,FAC FARM,DEPT QUIM ANALIT,E-28871 MADRID,SPAIN
[2] UNIV AUTONOMA MADRID,CSIC,INST CATALISIS,E-28049 MADRID,SPAIN
关键词
fructose; PQQ; fructose dehydrogenase; enzyme electrodes; flow injection analysis; amperometry;
D O I
10.1016/0003-2670(96)87686-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An enzyme carbon paste electrode for quantitation of fructose in a flow injection analysis (FIA) system is developed. The sensor is based on a commercially available pyrrolo quinoline quinone (PQQ)-fructose dehydrogenase. The enzyme is introduced into the carbon paste matrix and addition of polyethyleneimine (PEI) allows an unmediated anodic current to be achieved at 400 mV vs, Ag/AgCl after injections of fructose in the FIA system. Operating at 400 mV, at a flow rate of 1.0 ml min(-1) and with 20 mu l injection volume, the analytical characteristics of the sensor are: limit of detection 75 mu M (S/N 3), linearity up to 10 mM, sensitivity 3 nA mM(-1), complete specificity for fructose and operational stability for 10 h. The biosensor-FIA system has been validated by liquid chromatography-refractive index (LC-RI) for the detection of fructose in honey. Results prove the reliability of the biosensor for the quantitation of fructose in honey samples.
引用
收藏
页码:71 / 77
页数:7
相关论文
共 50 条
  • [41] Determination of D-fructose in foodstuffs by an improved amperometric biosensor based on a solid binding matrix
    Stredansky, M
    Pizzariello, A
    Stredanska, S
    Miertus, S
    [J]. ANALYTICAL COMMUNICATIONS, 1999, 36 (02): : 57 - 61
  • [42] A carbon black composite electrode for flow injection amperometric determination of hydrochlorothiazide
    Calegari, Francyelle
    de Oliveira, Paulo Roberto
    Marcolino Junior, Luiz Humberto
    Bergamini, Marcio F.
    [J]. ANALYTICAL METHODS, 2019, 11 (18) : 2422 - 2427
  • [43] SPECIFIC MICROMETHOD FOR DETERMINATION OF FRUCTOSE WITH D-MANNITOL DEHYDROGENASE
    YAMANAKA, K
    [J]. JOURNAL OF THE AGRICULTURAL CHEMICAL SOCIETY OF JAPAN, 1975, 49 (07): : 371 - 375
  • [44] DETERMINATION OF GLUCOSE, FRUCTOSE, AND SUCROSE IN FISH PASTE FOODS BY ENZYMATIC METHOD
    MIZOBUCHI, M
    KITADA, Y
    SASAKI, M
    UEDA, Y
    [J]. EISEI KAGAKU-JAPANESE JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1986, 32 (05): : 373 - 378
  • [45] Determination of sulfite by pervaporation-flow injection with amperometric detection using copper hexacyanoferrate-carbon nanotube modified carbon paste electrode
    Alamo, Lori Shayne T.
    Tangkuaram, Tanin
    Satienperakul, Sakchai
    [J]. TALANTA, 2010, 81 (4-5) : 1793 - 1799
  • [46] Flow injection determination of sialic acid based on amperometric detection
    Marzouk, Sayed A. M.
    Haddow, Jody D.
    Amin, Amr
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (02) : 647 - 653
  • [47] FT-Raman spectroscopic simultaneous determination of fructose and glucose in honey
    Batsoulis, AN
    Siatis, NG
    Kimbaris, AC
    Alissandrakis, EK
    Pappas, CS
    Tarantilis, PA
    Harizanis, PC
    Polissiou, MG
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2005, 53 (02) : 207 - 210
  • [48] A METHOD FOR THE DETERMINATION OF FRUCTOSE USING A SINGLE ENZYME - PRODUCTION AND PROPERTIES OF FRUCTOSE DEHYDROGENASE FROM GLUCONOBACTER-INDUSTRIUS
    PRADO, FE
    SAMPIETRO, AR
    [J]. BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 1994, 19 : 361 - 368
  • [49] FLOW-INJECTION AMPEROMETRIC DETECTION OF ANILINE WITH A PEROXIDASE MODIFIED CARBON-PASTE ELECTRODE
    DOMINGUEZSANCHEZ, P
    OSULLIVAN, CK
    MIRANDAORDIERES, AJ
    TUNONBLANCO, P
    SMYTH, MR
    [J]. ANALYTICA CHIMICA ACTA, 1994, 291 (03) : 349 - 356
  • [50] Carbon paste and PVC electrodes for the flow injection potentiometric determination of dextromethorphan
    Khaled, Elmorsy
    Hassan, H. N. A.
    Mohamed, Gehad G.
    Seleim, A. A.
    [J]. TALANTA, 2010, 81 (1-2) : 510 - 515