Amperometric sensor for the flow-injection determination of iridium(IV) ions

被引:0
|
作者
Shpigun, LK [1 ]
Kopytova, NE [1 ]
机构
[1] Russian Acad Sci, NS Kurnakov Gen & Inorgan Chem Inst, Moscow 117907, Russia
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical behavior of iridium(IV) chloride complexes was studied by cyclic and hydrodynamic voltammetry on carbon composite electrodes manufactured on the basis of a mixture of carbon powder and a hydrophobic silicone support covalently bonded with molecules of thiacrown compounds and their analogues. An amperometric sensor was proposed on the basis of an electrode modified by 1,4-dioxa-7,10-dithiacyclododecane, and its potential use for the flow-injection determination of iridium(IV) ions in chloride solutions was demonstrated. The calibration graph was Linear in the concentration range 0.05-0.50 mM Ir; the detection limit was 10 mu M. For the determination of iridium in model solutions containing Fe(II), Hg(II), Cu(II), Pd(IV), Pt(II), Rh(III), and (Ru(IV) ions, the relative standard deviation did not exceed 5% (n = 6). The throughput was 50-180 h(-1) for a sample volume of 400 mu L.
引用
收藏
页码:1157 / 1161
页数:5
相关论文
共 50 条
  • [1] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF PHARMACEUTICALS
    GONZALEZ, F
    TARIN, P
    MASPOCH, S
    BLANCO, M
    [J]. ARCHIV DER PHARMAZIE, 1988, 321 (10) : 725 - 728
  • [2] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF HYDROGEN-PEROXIDE BY OXIDATION AT AN IRIDIUM OXIDE ELECTRODE
    COX, JA
    LEWINSKI, K
    [J]. TALANTA, 1993, 40 (12) : 1911 - 1915
  • [3] Flow-injection amperometric sensor for quantification and speciation of iron
    Saavedra, Albert
    Corton, Eduardo
    [J]. 2014 IEEE 9TH IBERO-AMERICAN CONGRESS ON SENSORS (IBERSENSOR), 2014,
  • [4] PHOTOMETRIC AND AMPEROMETRIC FLOW-INJECTION DETERMINATION OF TRIAZOLAM AND CLOTIAZEPAM
    ALONSO, RM
    JIMENEZ, RM
    CARVAJAL, A
    GARCIA, J
    VICENTE, F
    HERNANDEZ, L
    [J]. TALANTA, 1989, 36 (07) : 761 - 765
  • [5] AMPEROMETRIC DETERMINATION OF BILIRUBIN WITH FLOW-INJECTION ANALYSIS SYSTEM
    BAE, ZU
    LEE, HL
    PARK, TM
    SEO, ML
    [J]. ANALYTICAL LETTERS, 1995, 28 (10) : 1775 - 1783
  • [6] DETERMINATION OF BROMAZEPAM BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION
    ZAROBE, ER
    BLANCO, MH
    ABAD, EL
    HERNANDEZ, YL
    [J]. ANALES DE QUIMICA SERIE B-QUIMICA INORGANICA Y QUIMICA ANALYTICA, 1988, 84 (01): : 120 - 122
  • [7] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF CHLORINE AT A GOLD ELECTRODE
    TSAOUSIS, AN
    HUBER, CO
    [J]. ANALYTICA CHIMICA ACTA, 1985, 178 (02) : 319 - 323
  • [8] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF DIFFUSION-COEFFICIENTS
    YANG, JN
    YAO, ZH
    GAO, ZP
    [J]. ANALYTICA CHIMICA ACTA, 1991, 246 (02) : 341 - 346
  • [9] AMPEROMETRIC DETERMINATION OF METAL-IONS IN A FLOW-INJECTION SYSTEM WITH A COPPER-AMALGAM ELECTRODE
    ALEXANDER, PW
    AKAPONGKUL, U
    [J]. ANALYTICA CHIMICA ACTA, 1983, 148 (APR) : 103 - 109
  • [10] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF CYANIDE ON A MODIFIED SILVER ELECTRODE
    NIKOLIC, SD
    MILOSAVLJEVIC, EB
    HENDRIX, JL
    NELSON, JH
    [J]. ANALYST, 1992, 117 (01) : 47 - 50