Amperometric sensor for the flow-injection determination of iridium(IV) ions

被引:0
|
作者
Shpigun, LK [1 ]
Kopytova, NE [1 ]
机构
[1] Russian Acad Sci, NS Kurnakov Gen & Inorgan Chem Inst, Moscow 117907, Russia
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical behavior of iridium(IV) chloride complexes was studied by cyclic and hydrodynamic voltammetry on carbon composite electrodes manufactured on the basis of a mixture of carbon powder and a hydrophobic silicone support covalently bonded with molecules of thiacrown compounds and their analogues. An amperometric sensor was proposed on the basis of an electrode modified by 1,4-dioxa-7,10-dithiacyclododecane, and its potential use for the flow-injection determination of iridium(IV) ions in chloride solutions was demonstrated. The calibration graph was Linear in the concentration range 0.05-0.50 mM Ir; the detection limit was 10 mu M. For the determination of iridium in model solutions containing Fe(II), Hg(II), Cu(II), Pd(IV), Pt(II), Rh(III), and (Ru(IV) ions, the relative standard deviation did not exceed 5% (n = 6). The throughput was 50-180 h(-1) for a sample volume of 400 mu L.
引用
收藏
页码:1157 / 1161
页数:5
相关论文
共 50 条
  • [41] INDIRECT DETERMINATION OF RARE-EARTHS BY AMPEROMETRIC DETECTION FOR FLOW-INJECTION ANALYSIS
    YEO, IH
    CHOI, KC
    EOM, TY
    [J]. BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 1991, 12 (01) : 10 - 12
  • [42] A flow-injection system with amperometric detection for selective determination of antioxidants in foodstuffs and drinks
    A. Ya. Yashin
    [J]. Russian Journal of General Chemistry, 2008, 78
  • [43] DC amperometric flow-injection analysis of ions and neutral molecules transduced by electroactive polymers
    Zavolskova, Marina
    Nikitina, Vita
    Karyakin, Arkady
    [J]. PROCEEDINGS OF THE 15TH INTERNATIONAL STUDENTS CONFERENCE MODERN ANALYTICAL CHEMISTRY, 2019, : 167 - 173
  • [44] SPECTROPHOTOMETRIC DETERMINATION OF PROMETHAZINE BY FLOW-INJECTION ANALYSIS AND OXIDATION BY CE(IV)
    CALATAYUD, JM
    SANCHO, TG
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1992, 10 (01) : 37 - 42
  • [45] CATALYTIC-FLUORIMETRIC DETERMINATION OF TI(IV) BY FLOW-INJECTION ANALYSIS
    LAZARO, F
    DECASTRO, L
    VALCARCEL, M
    [J]. ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1985, 18 (10): : 1209 - 1220
  • [46] AMPEROMETRIC TECHNIQUES IN FLOW-INJECTION ANALYSIS - DETERMINATION OF MAGNESIUM IN SERA AND NATURAL-WATERS
    DOWNARD, AJ
    HART, JB
    POWELL, HKJ
    XU, SH
    [J]. ANALYTICA CHIMICA ACTA, 1992, 269 (01) : 41 - 48
  • [47] Flow-injection amperometric determination of pesticides on the basis of their inhibition of immobilized acetylcholinesterases of different origin
    G. Jeanty
    A. Wojciechowska
    J.-L. Marty
    M. Trojanowicz
    [J]. Analytical and Bioanalytical Chemistry, 2002, 373 : 691 - 695
  • [48] DETERMINATION OF GLYCEROL IN WINE BY AMPEROMETRIC FLOW-INJECTION ANALYSIS WITH AN IMMOBILIZED GLYCEROL DEHYDROGENASE REACTOR
    MATSUMOTO, K
    MATSUBARA, H
    HAMADA, M
    DOI, T
    OSAJIMA, Y
    [J]. AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1991, 55 (04): : 1055 - 1059
  • [49] Flow-injection determination of phenols with tyrosinase amperometric biosensor and data processing by neural network
    Trojanowicz, M
    Jagielska, A
    Rotkiewicz, P
    Kierzek, A
    [J]. CHEMIA ANALITYCZNA, 1999, 44 (05): : 865 - 878
  • [50] Flow-Injection Pulsed-Amperometric Determination of Free Glycerol in Biodiesel at a Gold Electrode
    Barbosa, Tatielli G. G.
    Richter, Eduardo M.
    Munoz, Rodrigo A. A.
    [J]. ELECTROANALYSIS, 2012, 24 (05) : 1160 - 1163