Determination of chlorine ions in raw milk by pulsed amperometric detection in a flow injection system

被引:13
|
作者
Chen, Xingguang [1 ]
Chu, Beibei [1 ]
Xi, Huiting [1 ]
Xu, Junjun [1 ]
Lai, Lizhi [1 ]
Peng, Huifeng [1 ]
Deng, Danwen [1 ]
Huang, Ganhui [1 ]
机构
[1] Nanchang Univ, State Key Lab Food Sci & Technol, Nanchang 330047, Jiangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
chloride ion; pulsed amperometric detection; flow injection system; milk adulteration; ADULTERATION; CHROMATOGRAPHY; GOLD;
D O I
10.3168/jds.2018-14395
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Chloride ion concentration in milk was determined by pulsed amperometric detection in a flow injection system. Results showed that the Au electrode lost 3 electrons at 1.10 V and formed chloroaurate ions (AuCl4-) by combining with chloride ions, after which AuCl4- was partly reduced to Au at 0.6 V. Based on the electrochemical process, a triple waveform with detection potential of 1.15 V, detection time of 150 ms, oxidation potential of 1.4 V, oxidation time of 550 ms, reduction potential of 0 V, and reduction time of 400 ms was applied to the Au electrode for detecting chloride ion concentration in milk. The approach is rapid and automatic and features a detection limit of 0.005 g/L. The relative standard deviation obtained by 60 repetitive injections reached 1.48% at 2 g/L of NaCl. The method developed using the Au electrode without modification was used to analyze the chloride ion concentration in raw milk without preprocessing. The method showed good agreement with potentiometric titration.
引用
收藏
页码:9647 / 9658
页数:12
相关论文
共 50 条
  • [21] DETERMINATION OF BROMAZEPAM BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION
    ZAROBE, ER
    BLANCO, MH
    ABAD, EL
    HERNANDEZ, YL
    ANALES DE QUIMICA SERIE B-QUIMICA INORGANICA Y QUIMICA ANALYTICA, 1988, 84 (01): : 120 - 122
  • [22] Voltammetric behavior and determination by flow injection with amperometric detection of benzimidazoles
    de Prada, AGV
    Mena, ML
    Reviejo, AJ
    Pingarrón, JM
    ANALYTICAL LETTERS, 2004, 37 (01) : 65 - 79
  • [23] AMPEROMETRIC DETERMINATION OF METAL-IONS IN A FLOW-INJECTION SYSTEM WITH A COPPER-AMALGAM ELECTRODE
    ALEXANDER, PW
    AKAPONGKUL, U
    ANALYTICA CHIMICA ACTA, 1983, 148 (APR) : 103 - 109
  • [24] AMPEROMETRIC DETERMINATION OF BILIRUBIN WITH FLOW-INJECTION ANALYSIS SYSTEM
    BAE, ZU
    LEE, HL
    PARK, TM
    SEO, ML
    ANALYTICAL LETTERS, 1995, 28 (10) : 1775 - 1783
  • [25] Flow injection analysis of doxycycline or chlortetracycline in pharmaceutical formulations with pulsed amperometric detection
    Charoenraks, T
    Palaharn, S
    Grudpan, K
    Siangproh, W
    Chailapakul, O
    TALANTA, 2004, 64 (05) : 1247 - 1252
  • [26] Determination of traces of uranium in environmental samples using a flow injection system with amperometric catalytic detection
    Aguiar, MAS
    Marquez, KSG
    Gutz, IGR
    ELECTROANALYSIS, 2000, 12 (10) : 742 - 746
  • [28] FLOW-INJECTION DETERMINATION OF NITRITE BY AMPEROMETRIC DETECTION AT A MODIFIED ELECTRODE
    COX, JA
    KULKARNI, KR
    ANALYST, 1986, 111 (10) : 1219 - 1220
  • [29] Determination of arsenic in industrial samples by pervaporation flow injection with amperometric detection
    Rupasinghe, Thusitha W. T.
    Cardwell, Terence J.
    Cattrall, Robert W.
    Kolev, Spas D.
    ANALYTICA CHIMICA ACTA, 2009, 652 (1-2) : 266 - 271
  • [30] Flow Injection Analysis with Amperometric Detection for Morpholine Determination in Corrosion Inhibitors
    de Oliveira, Sanair M.
    Siguemura, Angelo
    Lima, Hugo O.
    de Souza, Flavia C.
    Magalhaes, Alvaro A. O.
    Toledo, Roberta M.
    D'Elia, Eliane
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2014, 25 (08) : 1399 - 1406