Determination of chlorine ions in raw milk by pulsed amperometric detection in a flow injection system

被引:13
|
作者
Chen, Xingguang [1 ]
Chu, Beibei [1 ]
Xi, Huiting [1 ]
Xu, Junjun [1 ]
Lai, Lizhi [1 ]
Peng, Huifeng [1 ]
Deng, Danwen [1 ]
Huang, Ganhui [1 ]
机构
[1] Nanchang Univ, State Key Lab Food Sci & Technol, Nanchang 330047, Jiangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
chloride ion; pulsed amperometric detection; flow injection system; milk adulteration; ADULTERATION; CHROMATOGRAPHY; GOLD;
D O I
10.3168/jds.2018-14395
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Chloride ion concentration in milk was determined by pulsed amperometric detection in a flow injection system. Results showed that the Au electrode lost 3 electrons at 1.10 V and formed chloroaurate ions (AuCl4-) by combining with chloride ions, after which AuCl4- was partly reduced to Au at 0.6 V. Based on the electrochemical process, a triple waveform with detection potential of 1.15 V, detection time of 150 ms, oxidation potential of 1.4 V, oxidation time of 550 ms, reduction potential of 0 V, and reduction time of 400 ms was applied to the Au electrode for detecting chloride ion concentration in milk. The approach is rapid and automatic and features a detection limit of 0.005 g/L. The relative standard deviation obtained by 60 repetitive injections reached 1.48% at 2 g/L of NaCl. The method developed using the Au electrode without modification was used to analyze the chloride ion concentration in raw milk without preprocessing. The method showed good agreement with potentiometric titration.
引用
收藏
页码:9647 / 9658
页数:12
相关论文
共 50 条
  • [31] DETERMINATION OF THE PESTICIDES FENTHION AND FENITROTHION BY FLOW-INJECTION WITH AMPEROMETRIC DETECTION
    MENDEZ, JH
    MARTINEZ, RC
    DOMINGUEZ, FB
    JIMENEZ, JIJ
    ANALYTICA CHIMICA ACTA, 1988, 209 (1-2) : 205 - 212
  • [32] DETERMINATION OF THE PESTICIDE GUTHION BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION
    MENDEZ, JH
    MARTINEZ, RC
    GONZALO, ER
    TRANCON, JP
    ELECTROANALYSIS, 1990, 2 (06) : 487 - 491
  • [33] Determination of choline in milk, milk powder, and soy lecithin hydrolysates by flow injection analysis and amperometric detection with a choline oxidase based biosensor
    Pati, S
    Quinto, M
    Palmisano, F
    Zambonin, PG
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (15) : 4638 - 4642
  • [34] Flow injection determination of chloride ions with spectrophotometric detection
    Cheregi, M
    Danet, AF
    ANALYTICAL LETTERS, 1997, 30 (15) : 2847 - 2858
  • [36] Aflatoxin M1 determination in raw milk using a flow-injection immunoassay system
    Badea, M
    Micheli, L
    Messia, MC
    Candigliota, T
    Marconi, E
    Mottram, T
    Velasco-Garcia, M
    Moscone, D
    Palleschi, G
    ANALYTICA CHIMICA ACTA, 2004, 520 (1-2) : 141 - 148
  • [37] Fast Determination of Naproxen in Pharmaceutical Formulations by Batch Injection Analysis with Pulsed Amperometric Detection
    Stefano, Jessica S.
    de Lima, Ana Paula
    Montes, Rodrigo H. O.
    Richter, Eduardo M.
    Munoz, Rodrigo A. A.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2012, 23 (10) : 1834 - 1838
  • [38] A biosensor for the determination of ammonium ion using flow injection amperometric system
    Preeyanut Butmee
    Sarawut Prasertsri
    Saichol Pimmongkol
    Gamolwan Tumcharern
    Albana Veseli
    Eda Mehmeti
    Kurt Kalcher
    Anchalee Samphao
    Monatshefte für Chemie - Chemical Monthly, 2017, 148 : 635 - 644
  • [39] A biosensor for the determination of ammonium ion using flow injection amperometric system
    Butmee, Preeyanut
    Prasertsri, Sarawut
    Pimmongkol, Saichol
    Tumcharern, Gamolwan
    Veseli, Albana
    Mehmeti, Eda
    Kalcher, Kurt
    Samphao, Anchalee
    MONATSHEFTE FUR CHEMIE, 2017, 148 (04): : 635 - 644
  • [40] DETERMINATION OF MYOINOSITOL IN A FLOW-INJECTION SYSTEM WITH CO-IMMOBILIZED ENZYME REACTORS AND AMPEROMETRIC DETECTION
    OLSSON, B
    MARKOVARGA, G
    GORTON, L
    APPELQVIST, R
    JOHANSSON, G
    ANALYTICA CHIMICA ACTA, 1988, 206 (1-2) : 49 - 55