Nail thickness measurements using optical coherence tomography and 20-MHz ultrasonography

被引:53
|
作者
Mogensen, M.
Thomsen, J. B.
Skovgaard, L. T.
Jemec, G. B. E.
机构
[1] Roskilde Hosp, Dept Dermatol, DK-4000 Roskilde, Denmark
[2] Tech Univ Denmark, Risoe Natl Lab, Opt & Plasma Res Dept, Roskilde, Denmark
[3] Univ Copenhagen, Dept Biostat, Copenhagen, Denmark
关键词
nail imaging; nail thickness; optical coherence tomography; ultrasound;
D O I
10.1111/j.1365-2133.2007.08118.x
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background Nail diseases are often troubling to the patient and may present a diagnostic challenge to the dermatologist. Biopsies from the nail may be required although often perceived uncomfortable by the patient and potentially scarring. Noninvasive technologies are therefore of particular interest in the study of nails. Optical coherence tomography (OCT) is an optical imaging modality which may provide improved data. Objectives This study evaluates nail morphology and thickness in OCT images in comparison with high-frequency ultrasound (HFUS) imaging of the nail. Methods Ten healthy volunteers were recruited for imaging and nail measurements; OCT and HFUS images were compared qualitatively. Nail thickness measurements with four different techniques were compared: ultrasound, OCT, polarization-sensitive (PS) OCT and callipers. The OCT system was developed at Risoe National Laboratory, Denmark. A commercially available 20-MHz ultrasound system (Dermascan; Cortex Technology, Hadsund, Denmark) was used. Results In standard OCT the nail plate appeared as a layered structure containing a varying number of horizontal homogeneous bands of varying intensity and thickness. PS-OCT images of the nail plate also showed a layered structure. The refractive index of the nail was 1.47 +/- 0.09. OCT and PS-OCT had low coefficients of variation, 6.31 and 6.53, respectively, compared with other methods: HFUS 12.70 and callipers 14.03. Conclusions PS-OCT has to our knowledge not been applied to OCT analysis of the nail, and offers some advantages in separation of the nail bed from the nail plate.
引用
收藏
页码:894 / 900
页数:7
相关论文
共 50 条
  • [31] Retinal thickness measurements with optical coherence tomography and the scanning retinal thickness analyzer
    Konno, S
    Akiba, J
    Yoshida, A
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2001, 21 (01): : 57 - 61
  • [32] Repeatability of retinal thickness measurements in children using spectral domain optical coherence tomography
    Boned-Murillo, Ana
    Garcia, Diana Perez
    Diaz, Maria Dolores
    Cano, Ana Sanchez
    Remon, Leon
    Hospital, Elvira Orduna
    Fernandez-Espinosa, Guisela
    Pinilla, Maria Sopena
    Rivases, Guillermo Perez
    Lozano, Isabel Pinilla
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [33] Macular thickness measurements in normal eyes using spectral domain optical coherence tomography
    Legarreta, John E.
    Gregori, Giovanni
    Punjabi, Omar S.
    Knighton, Robert W.
    Lalwani, Geeta A.
    Puliafito, Carmen A.
    OPHTHALMIC SURGERY LASERS & IMAGING, 2008, 39 (04) : S43 - S49
  • [34] Reproducibility of Retinal Thickness Measurements in Healthy Subjects Using Spectralis Optical Coherence Tomography
    Menke, Marcel N.
    Dabov, Simeon
    Knecht, Pascal
    Sturm, Veit
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (03) : 467 - 472
  • [35] A robust algorithm for retinal thickness measurements using optical coherence tomography (Stratus OCT)
    Gregori, G
    Knighton, RW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U50 - U50
  • [36] Standardization of choroidal thickness measurements using enhanced depth imaging optical coherence tomography
    Boonarpha, Nattapon
    Zheng, Yalin
    Stangos, Alexandros N.
    Lu, Huiqi
    Raj, Ankur
    Czanner, Gabriela
    Harding, Simon P.
    Nair-Sahni, Jayashree
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (03) : 484 - 491
  • [37] Standardization of choroidal thickness measurements using enhanced depth imaging optical coherence tomography
    Nattapon Boonarpha
    Yalin Zheng
    Alexandros N.Stangos
    Huiqi Lu
    Ankur Raj
    Gabriela Czanner
    Simon P.Harding
    Jayashree Nair-Sahni
    International Journal of Ophthalmology, 2015, 8 (03) : 484 - 491
  • [38] Reproducibility and reliability of intraretinal layer thickness measurements in mice using optical coherence tomography
    Cruz-Herranz, Andres
    Albrecht, Philipp
    Yiu, Hao
    Balk, Lisanne
    Green, Ari
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [39] Repeatability and Reproducibility of Macular Thickness Measurements Using Fourier Domain Optical Coherence Tomography
    Bruce, Alison
    Pacey, Ian E.
    Dharni, Poonam
    Scally, Andy J.
    Barrett, Brendan T.
    OPEN OPHTHALMOLOGY JOURNAL, 2009, 3 : 10 - 14
  • [40] Retinal thickness measurements from optical coherence tomography using a Markov boundary model
    Koozekanani, D
    Boyer, K
    Roberts, C
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (09) : 900 - 916