Nail thickness measurements using optical coherence tomography and 20-MHz ultrasonography

被引:53
|
作者
Mogensen, M.
Thomsen, J. B.
Skovgaard, L. T.
Jemec, G. B. E.
机构
[1] Roskilde Hosp, Dept Dermatol, DK-4000 Roskilde, Denmark
[2] Tech Univ Denmark, Risoe Natl Lab, Opt & Plasma Res Dept, Roskilde, Denmark
[3] Univ Copenhagen, Dept Biostat, Copenhagen, Denmark
关键词
nail imaging; nail thickness; optical coherence tomography; ultrasound;
D O I
10.1111/j.1365-2133.2007.08118.x
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background Nail diseases are often troubling to the patient and may present a diagnostic challenge to the dermatologist. Biopsies from the nail may be required although often perceived uncomfortable by the patient and potentially scarring. Noninvasive technologies are therefore of particular interest in the study of nails. Optical coherence tomography (OCT) is an optical imaging modality which may provide improved data. Objectives This study evaluates nail morphology and thickness in OCT images in comparison with high-frequency ultrasound (HFUS) imaging of the nail. Methods Ten healthy volunteers were recruited for imaging and nail measurements; OCT and HFUS images were compared qualitatively. Nail thickness measurements with four different techniques were compared: ultrasound, OCT, polarization-sensitive (PS) OCT and callipers. The OCT system was developed at Risoe National Laboratory, Denmark. A commercially available 20-MHz ultrasound system (Dermascan; Cortex Technology, Hadsund, Denmark) was used. Results In standard OCT the nail plate appeared as a layered structure containing a varying number of horizontal homogeneous bands of varying intensity and thickness. PS-OCT images of the nail plate also showed a layered structure. The refractive index of the nail was 1.47 +/- 0.09. OCT and PS-OCT had low coefficients of variation, 6.31 and 6.53, respectively, compared with other methods: HFUS 12.70 and callipers 14.03. Conclusions PS-OCT has to our knowledge not been applied to OCT analysis of the nail, and offers some advantages in separation of the nail bed from the nail plate.
引用
收藏
页码:894 / 900
页数:7
相关论文
共 50 条
  • [21] The repeatability of corneal and corneal epithelial thickness measurements using optical coherence tomography
    Sin, Sokpheaktra
    Simpson, Trefford L.
    OPTOMETRY AND VISION SCIENCE, 2006, 83 (06) : 360 - 365
  • [22] Retinal thickness measurements in optical coherence tomography using a Markov boundary model
    Koozekanani, D
    Boyer, K
    Roberts, C
    IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, PROCEEDINGS, VOL II, 2000, : 363 - 370
  • [23] Evaluation of the atrophogenic potential of different glucocorticoids using optical coherence tomography, 20-MHz ultrasound and profilometry; a double-blind, placebo-controlled trial
    Cossmann, M.
    Welzel, J.
    BRITISH JOURNAL OF DERMATOLOGY, 2006, 155 (04) : 700 - 706
  • [24] Evaluation of 20-MHz high-frequency ultrasonography for the diagnosis of choroidal nevi
    Albrieux, Magali
    Pegourie, Pierre
    Aptel, Florent
    Satger, Dominique
    Bru, Marc
    Zaatar, Georges
    Chiquet, Christophe
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (01) : 181 - 189
  • [25] Value of preoperative determination of skin tumor thickness with 20-MHz ultrasound
    Jovanovic, DL
    Katic, V
    Jovanovic, B
    ARCHIVES OF DERMATOLOGY, 2005, 141 (02) : 269 - 270
  • [26] Automated measurements of retinal thickness with optical coherence tomography - Reply
    Ray, R
    Stinnett, SS
    Jaffe, GJ
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (02) : 351 - 351
  • [27] Errors in retinal thickness measurements obtained by optical coherence tomography
    Sadda, SR
    Wu, ZQ
    Walsh, AC
    Richine, L
    Dougall, J
    Cortez, R
    LaBree, LD
    OPHTHALMOLOGY, 2006, 113 (02) : 285 - 293
  • [28] Repeatability and reproducibility of corneal thickness measurements by optical coherence tomography
    Muscat, S
    McKay, N
    Parks, S
    Kemp, E
    Keating, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 (06) : 1791 - 1795
  • [29] Imaging the lacrimal canaliculus with 20-MHz ultrasonography: a normal diagnosis (Part 1)
    Ostendorf, M
    Tost, F
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2003, 26 (10): : 1031 - 1034
  • [30] Evaluation of 20-MHz high-frequency ultrasonography for the diagnosis of choroidal nevi
    Magali Albrieux
    Pierre Pégourié
    Florent Aptel
    Dominique Satger
    Marc Bru
    Georges Zaatar
    Christophe Chiquet
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2021, 259 : 181 - 189