Nail thickness measurements using optical coherence tomography and 20-MHz ultrasonography

被引:53
|
作者
Mogensen, M.
Thomsen, J. B.
Skovgaard, L. T.
Jemec, G. B. E.
机构
[1] Roskilde Hosp, Dept Dermatol, DK-4000 Roskilde, Denmark
[2] Tech Univ Denmark, Risoe Natl Lab, Opt & Plasma Res Dept, Roskilde, Denmark
[3] Univ Copenhagen, Dept Biostat, Copenhagen, Denmark
关键词
nail imaging; nail thickness; optical coherence tomography; ultrasound;
D O I
10.1111/j.1365-2133.2007.08118.x
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background Nail diseases are often troubling to the patient and may present a diagnostic challenge to the dermatologist. Biopsies from the nail may be required although often perceived uncomfortable by the patient and potentially scarring. Noninvasive technologies are therefore of particular interest in the study of nails. Optical coherence tomography (OCT) is an optical imaging modality which may provide improved data. Objectives This study evaluates nail morphology and thickness in OCT images in comparison with high-frequency ultrasound (HFUS) imaging of the nail. Methods Ten healthy volunteers were recruited for imaging and nail measurements; OCT and HFUS images were compared qualitatively. Nail thickness measurements with four different techniques were compared: ultrasound, OCT, polarization-sensitive (PS) OCT and callipers. The OCT system was developed at Risoe National Laboratory, Denmark. A commercially available 20-MHz ultrasound system (Dermascan; Cortex Technology, Hadsund, Denmark) was used. Results In standard OCT the nail plate appeared as a layered structure containing a varying number of horizontal homogeneous bands of varying intensity and thickness. PS-OCT images of the nail plate also showed a layered structure. The refractive index of the nail was 1.47 +/- 0.09. OCT and PS-OCT had low coefficients of variation, 6.31 and 6.53, respectively, compared with other methods: HFUS 12.70 and callipers 14.03. Conclusions PS-OCT has to our knowledge not been applied to OCT analysis of the nail, and offers some advantages in separation of the nail bed from the nail plate.
引用
收藏
页码:894 / 900
页数:7
相关论文
共 50 条
  • [1] Macular hole evaluation with 10-MHz and 20-MHz ultrasonography and optical coherence tomography
    Siahmed, K
    Berges, O
    Brasseur, G
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2005, 28 (07): : 733 - 736
  • [2] Assessment of Tumor Thickness in Melanocytic Skin Lesions: Comparison of Optical Coherence Tomography, 20-MHz Ultrasound and Histopathology
    Hinz, Torsten
    Ehler, Lin-Kristin
    Voth, Harald
    Fortmeier, Ines
    Hoeller, Tobias
    Hornung, Thorsten
    Schmid-Wendtner, Monika-Hildegard
    DERMATOLOGY, 2011, 223 (02) : 161 - 168
  • [3] In vivo thickness measurement of basal cell carcinoma and actinic keratosis with optical coherence tomography and 20-MHz ultrasound
    Mogensen, M.
    Nurnberg, B. M.
    Forman, J. L.
    Thomsen, J. B.
    Thrane, L.
    Jemec, G. B. E.
    BRITISH JOURNAL OF DERMATOLOGY, 2009, 160 (05) : 1026 - 1033
  • [4] Comparisons of choroidal nevus measurements obtained using 10-and 20-MHz ultrasound and spectral domain optical coherence tomography
    Martins, Maira de Franca
    Kiefer, Kelcia
    Andrade Kanecadan, Liliane Almeida
    Garcia, Patricia Novita
    Belfort, Rubens N.
    Allemann, Norma
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2017, 80 (02) : 78 - 83
  • [5] Preoperative Characterization of Basal Cell Carcinoma Comparing Tumour Thickness Measurement by Optical Coherence Tomography, 20-MHz Ultrasound and Histopathology
    Hinz, Torsten
    Ehler, Lin-Kristin
    Hornung, Thorsten
    Voth, Harald
    Fortmeier, Ines
    Maier, Tanja
    Hoeller, Tobias
    Schmid-Wendtner, Monika-Hildegard
    ACTA DERMATO-VENEREOLOGICA, 2012, 92 (02) : 132 - 137
  • [6] Evaluation of Methylprednisolone Aceponate, Tacrolimus, and Combination Thereof in the Psoriasis Plaque Test by Sum Score, 20-Mhz Ultrasonography, and Optical Coherence Tomography
    Buder, Kristina
    Wozel, Gottfried
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2009, 104 (06) : 494 - 494
  • [7] Macular hole: 10 and 20-MHz ultrasound and spectral-domain optical coherence tomography
    Bottos, Juliana Mantovani
    Lucas Torres, Virginia Laura
    Almeida Kanecadan, Liliane Andrade
    Gonzalez Martinez, Andrea Alejandra
    Bueno Moraes, Nilva Simeren
    Maia, Mauricio
    Allemann, Norma
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2012, 75 (06) : 415 - 419
  • [8] Comparison of Lens Thickness Measurements Using the Anterior Segment Optical Coherence Tomography and A-scan Ultrasonography
    Zeng, Yangfa
    Liu, Yizhi
    Liu, Xing
    Chen, Chuying
    Xia, Yuanling
    Lu, Miaoling
    He, Mingguang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (01) : 290 - 294
  • [9] Reproducibility of retinal thickness measurements using Optical Coherence Tomography
    Wang, RC
    Koozekanani, D
    Herderick, EE
    Roberts, C
    Katz, SE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S125 - S125
  • [10] Retinal thickness measurements with optical coherence biometry and optical coherence tomography
    Resch, Miklos D.
    Takats, Judit
    Csakany, Bela
    Maneschg, Otto
    Marsovszky, Laszlo
    Szabo, Antal
    Papp, Andras
    Nemeth, Janos
    SPEKTRUM DER AUGENHEILKUNDE, 2014, 28 (03) : 121 - 125