Contact and Non-contact Heart Beat Rate Measurement Techniques: Challenges and Issues

被引:1
|
作者
Khong, Wei Leong [1 ]
Mariappan, Muralindran [2 ]
Chong, Chee Siang [2 ]
机构
[1] Monash Univ Malaysia, Sch Engn, Subang Jaya 47500, Selangor, Malaysia
[2] Univ Malaysia Sabah, Fac Engn, Kota Kinabalu 88400, Sabah, Malaysia
来源
关键词
Electrocardiogram; heart beat rate; oscillometric method; photoplethysmography imaging; photoplethysmography; BLOOD-PRESSURE; PHOTOPLETHYSMOGRAPHY; HISTORY;
D O I
10.47836/pjst.29.3.03
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The heart is the most important organ in the human body as it circulates the blood throughout the body through blood vessels. In the human circulatory system, the heart beats according to the body's physical needs. Therefore, the physical condition of a person can be determined by observing the heartbeat rate (HBR). There are plenty of methods that can be used to measure the HBR. Among the methods, photoplethysmography (PPG), electrocardiogram (ECG) and the oscillometric method are the standard methods utilised in medical institutes for continuous measurement of the HBR of a patient. Out of these three methods, PPG is the only method which has evolved to a non-contact imaging-based method from the conventional contact sensory based method. The incentive for developing the non-contact-based imaging PPG method in measuring the HBR provides the advantage of excluding the direct contact of sensors on specific body parts. This brings huge improvements to remote monitoring of healthcare especially for the purpose of social distancing. Moreover, the rapid progression of technology (particularly the interactive electronic gadgets advancement) also motivates researchers and engineers to create a mobile application using the PPG imaging method, which is feasible in measuring the HBR. Hence, this study seeks to review and present the fundamental concept, the present research and the evolution of the aforementioned methods in measuring the HBR.
引用
收藏
页码:1707 / 1732
页数:26
相关论文
共 50 条
  • [1] The Evolution of Heart Beat Rate Measurement Techniques From Contact Based Photoplethysmography to Non-Contact Based Photoplethysmography Imaging
    Khong, Wei Leong
    Mariappan, Muralindran
    2019 4TH IEEE INTERNATIONAL CIRCUITS AND SYSTEMS SYMPOSIUM (ICSYS), 2019,
  • [2] Non-contact measurement of the heart rate and the heart rate variability
    Kranjec, Jure
    Begus, Samo
    Gersak, Gregor
    Drnovsek, Janko
    ELEKTROTEHNISKI VESTNIK, 2013, 80 (03): : 135 - 140
  • [3] Non-contact Measurement of the Heart Rate by a Image Sensor
    Bernacchia, Natascia
    Marchionni, Paolo
    Ercoli, Ilaria
    Scalise, Lorenzo
    SENSORS, 2015, 319 : 371 - 375
  • [4] Non-contact Methods for Heart Rate Measurement: A Review
    Kaur, Gaganjot
    Kilby, Jeff
    2021 INTERNATIONAL CONFERENCE ON COMPUTING SCIENCES (ICCS 2021), 2021, : 289 - 294
  • [5] Non-contact Measurement of Heart Rate Based on Facial Video
    Wang, Cheng
    Jiang, Yuling
    Cai, Zhuohao
    Lin, Lan
    2019 PHOTONICS & ELECTROMAGNETICS RESEARCH SYMPOSIUM - FALL (PIERS - FALL), 2019, : 2269 - 2275
  • [6] Non-contact Heart Rate Measurement based on Camera Image
    Kitajima, Toshihiro
    Choi, SangOn
    Murakami, Edwardo Arata Y.
    JOURNAL OF INFORMATION ASSURANCE AND SECURITY, 2015, 10 (03): : 120 - 129
  • [7] The Non-Contact Heart Rate Measurement System for Monitoring HRV
    Huang, Ji-Jer
    Yu, Sheng-, I
    Syu, Hao-Yi
    See, Aaron Raymond
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 3238 - 3241
  • [8] Study on Non-contact Heart Beat Measurement Method by Using Depth Sensor
    Aoki, Hirooki
    Suzuki, Atsushi
    Shiga, Tsuyoshi
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 341 - 345
  • [9] A Comparative Study of Video Signals for Non-contact Heart Rate Measurement
    Lueangwattana, Chanya
    Kondo, Toshiaki
    Haneishi, Hideaki
    2015 12TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2015,
  • [10] A non-contact ECG measurement system for pervasive heart rate detection
    Zhu, Da-Huan
    Wang, Lei
    Zhang, Yuan-Ting
    2008 INTERNATIONAL SPECIAL TOPIC CONFERENCE ON INFORMATION TECHNOLOGY AND APPLICATIONS IN BIOMEDICINE, VOLS 1 AND 2, 2008, : 551 - 552