Polyaxial locking plates in treating distal humeral fractures: a comparative randomized trial for clinical outcome

被引:4
|
作者
Croenlein, Moritz [1 ]
Lucke, Martin [3 ]
Beirer, Marc [1 ]
Pfoerringer, Dominik [1 ]
Kirchhoff, Chlodwig [1 ]
Biberthaler, Peter [1 ]
Braun, Karl F. [1 ]
Siebenlist, Sebastian [1 ,2 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Trauma Surg, Ismaninger Str 22, D-81675 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Dept Orthopaed Sports Med, Ismaninger Str 22, D-81675 Munich, Germany
[3] Chirurg Klinikum Munchen Sud, Dept Trauma Surg, Isarkanal 30, D-81379 Munich, Germany
来源
关键词
Distal humeral fracture; Locking plate; Anatomical preshaped; Polyaxial; Outcome; INTRAARTICULAR FRACTURES; FEMUR FRACTURES; FIXATION; CONFIGURATION; STABILITY; SYSTEMS; SCREWS;
D O I
10.1186/s12891-017-1910-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Management of distal humeral fractures remains to be one of the most challenging aspects in trauma surgery. Low profile plating systems with variable angle screw fixation represent a crucial advancement to the established angular stable locking plates with considerable attention in current research. The aim of the prospective randomized trial was to review the preliminary results and patients' outcome following treatment with these newly developed implants and to rule out potential differences in fracture treatment of two different plating systems. Methods: Twenty patients with distal humeral fractures (AO 13-A1 - AO 13-C3) were included in the current study since 2014. After completing the randomization plan, patients were distributed into two groups for different variable angle locking plates (DePuy Synthes (R) VA-LCP vs. Medartis (R) Aptus Elbow). Functional elbow scoring (ROM, MEPS, QuickDASH) served as primary outcome parameter, while radiological fracture consolidation served as secondary outcome parameter. Follow-ups were conducted 6 weeks, 12 weeks, 6 months and 12 months after the operation. Results: Seventeen of 20 patients (85%) concluded all follow-up examinations. Postoperative elbow extension deficiencies showed significant differences between the two groups in all follow-up examinations with a mean of (sic) 18 +/- 7.4 degrees in the DePuy Synthes (R) VA-LCP group compared to a mean of (sic) 6.5 +/- 7.5 degrees in the Medartis (R) Aptus Elbow group (p = 0.002) 12 months postoperatively. Functional scoring showed a disparate pattern. The Medartis (R) Aptus Elbow group achieved significantly better MEP scores during follow-up. However, the analysis of the QuickDash revealed better results of the DePuy Synthes (R) VA-LCP group in the first half and better results of the Medartis (R) Aptus Elbow group in the second half of the follow-up examination instead. Conclusions: Considering the complexity of distal humeral fractures, the usage of anatomically preshaped low profile variable angle locking plates for operative treatment leads to good clinical results. Even though there might be some advances of the Medartis (R) Aptus Elbow plating system concerning postoperative ROM and elbow function, a consistent difference in the overall clinical outcome between the two plating systems could not be detected.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] The outcome of surgical management of proximal humeral fractures using locking plates: comparison between Locking plates with different geometry
    Chen, Jiun-Liang
    Chang, Fu-Chun
    Lin, Shih-Jie
    Chuang, Po-Yao
    Peng, Kuo-Ti
    Huang, Kuo-Chin
    Huang, Tsan-Wen
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (12) : 2159 - 2166
  • [22] Comparative study of T-plates and locking plates in the management of displaced proximal humeral fractures
    Yan, Denglu
    Soon, Yancheng
    CURRENT ORTHOPAEDIC PRACTICE, 2012, 23 (04): : 351 - 355
  • [23] Adjuvant Arthroscopy Does Not Improve the Functional Outcome of Volar Locking Plate for Distal Radius Fractures: A Randomized Clinical Trial
    Perez-Ubeda, Maria Jose
    Arribas, Pedro
    Garcia-Andrade, M. Dolores Gimeno
    Garvin, Lucia
    Rodriguez, Alberto
    Ponz, Virginia
    Ballester, Sandra
    Fernandez, Sergio
    Fuentes-Ferrer, Manuel
    Ascaso, Ana
    Portoles-Perez, Antonio
    Marco, Fernando
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2024, 40 (02): : 305 - 317
  • [24] Clinical outcome and quality of life of patients with periprosthetic distal femur fractures and retained total knee arthroplasty treated with polyaxial locking plates: a single-center experience
    Lotzien, Sebastian
    Hoberg, Clemens
    Hoffmann, Martin F.
    Schildhauer, Thomas A.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (01): : 189 - 196
  • [25] Clinical outcome and quality of life of patients with periprosthetic distal femur fractures and retained total knee arthroplasty treated with polyaxial locking plates: a single-center experience
    Sebastian Lotzien
    Clemens Hoberg
    Martin F. Hoffmann
    Thomas A. Schildhauer
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 189 - 196
  • [26] Locking versus non-locking one-third tubular plates for treating osteoporotic distal fibula fractures: a comparative study
    Herrera-Perez, Mario
    Gutierrez-Morales, Maria J.
    Guerra-Ferraz, Ayron
    Pais-Brito, Jose L.
    Boluda-Mengod, Juan
    Garces, Gerardo L.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 : S60 - S65
  • [27] Results in treatment of distal femur fractures using polyaxial locking plate
    Pascarella, R.
    Bettuzzi, C.
    Bosco, G.
    Leonetti, D.
    Dessi, S.
    Forte, P.
    Amendola, L.
    STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2014, 9 (01): : 13 - 18
  • [28] Polyaxial locking plate fixation in distal femur fractures: A biomechanical comparison
    Wilkens, Kenneth J.
    Curtiss, Shane
    Lee, Mark A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (09) : 624 - 628
  • [29] Polyaxial versus uniaxial volar locking plate for distal radial fractures
    Al-Mouazzen, Louay
    Chou, Daud Tai Shan
    Kyriakopoulos, Georgios
    Hambidge, John
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (01) : 9 - 12
  • [30] Biomechanical Comparison of Polyaxial-Type Locking Plates and a Fixed-Angle Locking Plate for Internal Fixation of Distal Femur Fractures
    Otto, Randall J.
    Moed, Berton R.
    Bledsoe, J. Gary
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (09) : 645 - 652