Polyaxial locking plates in treating distal humeral fractures: a comparative randomized trial for clinical outcome

被引:4
|
作者
Croenlein, Moritz [1 ]
Lucke, Martin [3 ]
Beirer, Marc [1 ]
Pfoerringer, Dominik [1 ]
Kirchhoff, Chlodwig [1 ]
Biberthaler, Peter [1 ]
Braun, Karl F. [1 ]
Siebenlist, Sebastian [1 ,2 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Trauma Surg, Ismaninger Str 22, D-81675 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Dept Orthopaed Sports Med, Ismaninger Str 22, D-81675 Munich, Germany
[3] Chirurg Klinikum Munchen Sud, Dept Trauma Surg, Isarkanal 30, D-81379 Munich, Germany
来源
关键词
Distal humeral fracture; Locking plate; Anatomical preshaped; Polyaxial; Outcome; INTRAARTICULAR FRACTURES; FEMUR FRACTURES; FIXATION; CONFIGURATION; STABILITY; SYSTEMS; SCREWS;
D O I
10.1186/s12891-017-1910-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Management of distal humeral fractures remains to be one of the most challenging aspects in trauma surgery. Low profile plating systems with variable angle screw fixation represent a crucial advancement to the established angular stable locking plates with considerable attention in current research. The aim of the prospective randomized trial was to review the preliminary results and patients' outcome following treatment with these newly developed implants and to rule out potential differences in fracture treatment of two different plating systems. Methods: Twenty patients with distal humeral fractures (AO 13-A1 - AO 13-C3) were included in the current study since 2014. After completing the randomization plan, patients were distributed into two groups for different variable angle locking plates (DePuy Synthes (R) VA-LCP vs. Medartis (R) Aptus Elbow). Functional elbow scoring (ROM, MEPS, QuickDASH) served as primary outcome parameter, while radiological fracture consolidation served as secondary outcome parameter. Follow-ups were conducted 6 weeks, 12 weeks, 6 months and 12 months after the operation. Results: Seventeen of 20 patients (85%) concluded all follow-up examinations. Postoperative elbow extension deficiencies showed significant differences between the two groups in all follow-up examinations with a mean of (sic) 18 +/- 7.4 degrees in the DePuy Synthes (R) VA-LCP group compared to a mean of (sic) 6.5 +/- 7.5 degrees in the Medartis (R) Aptus Elbow group (p = 0.002) 12 months postoperatively. Functional scoring showed a disparate pattern. The Medartis (R) Aptus Elbow group achieved significantly better MEP scores during follow-up. However, the analysis of the QuickDash revealed better results of the DePuy Synthes (R) VA-LCP group in the first half and better results of the Medartis (R) Aptus Elbow group in the second half of the follow-up examination instead. Conclusions: Considering the complexity of distal humeral fractures, the usage of anatomically preshaped low profile variable angle locking plates for operative treatment leads to good clinical results. Even though there might be some advances of the Medartis (R) Aptus Elbow plating system concerning postoperative ROM and elbow function, a consistent difference in the overall clinical outcome between the two plating systems could not be detected.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Clinical outcome of locking plate fixation in distal tibia fractures
    Mohebi, Ahmad Shakib
    Nadeem, Rana Dilawaiz
    Sah, Ranjit Kumar
    Mohy-Ud-Din, Iftikhar
    Akhtar, Muhammad
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2023, 73 (05) : 1083 - 1086
  • [32] Regarding "Adjuvant Arthroscopy Does Not Improve the Functional Outcome of Volar Locking Plate for Distal Radius Fractures: A Randomized Clinical Trial"
    Bargemon, Jean-Baptiste de Villeneuve
    Lupon, Elise
    Witters, Marie
    Brenac, Camille
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2024, 40 (03): : 659 - 660
  • [33] Functional outcome of open distal femoral fractures managed with lateral locking plates
    Deepak Jain
    Raghav Arora
    Rajnish Garg
    Pankaj Mahindra
    Harpal S. Selhi
    International Orthopaedics, 2020, 44 : 725 - 733
  • [34] Functional outcome of open distal femoral fractures managed with lateral locking plates
    Jain, Deepak
    Arora, Raghav
    Garg, Rajnish
    Mahindra, Pankaj
    Selhi, Harpal S.
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (04) : 725 - 733
  • [35] Minimally Invasive Polyaxial Locking Plate Fixation of Proximal Humeral Fractures: A Prospective Study
    Ruchholtz, Steffen
    Hauk, Carsten
    Lewan, Ulrike
    Franz, Daniel
    Kuehne, Christian
    Zettl, Ralph
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 71 (06): : 1737 - 1744
  • [36] Mid term results of Distal Femoral Fractures treated with a Polyaxial Locking Plate
    Erhardt, J. B.
    Vincenti, M.
    Pressmar, J.
    Gebhard, F.
    Kuster, M. S.
    SWISS MEDICAL WEEKLY, 2010, 140 (23-24) : 34S - 34S
  • [37] Monoaxial versus polyaxial locking systems: a biomechanical analysis of different locking systems for the fixation of proximal humeral fractures
    Zettl, Ralph
    Mueller, Thorben
    Topp, Tobias
    Lewan, Ulrike
    Krueger, Antonio
    Kuehne, Christian
    Ruchholtz, Steffen
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (08) : 1245 - 1250
  • [38] Monoaxial versus polyaxial locking systems: a biomechanical analysis of different locking systems for the fixation of proximal humeral fractures
    Ralph Zettl
    Thorben Müller
    Tobias Topp
    Ulrike Lewan
    Antonio Krüger
    Christian Kühne
    Steffen Ruchholtz
    International Orthopaedics, 2011, 35 : 1245 - 1250
  • [39] Outcome of locking compression plates in humeral shaft nonunions
    Malhar N. Kumar
    V. Pratap Ravindranath
    M. R. Ravishankar
    Indian Journal of Orthopaedics, 2013, 47 : 150 - 155
  • [40] The Use of Locking Plates in Proximal Humeral Fractures: Comparison of Outcome by Patient Age and Fracture Pattern
    Alao, Uthman
    Leonard, Michael
    Mokotedi, Leibo
    Glynn, Aaron
    Dolan, Mark
    Fleming, Pat
    IRISH JOURNAL OF MEDICAL SCIENCE, 2010, 179 : S154 - S154