A new gold-standard dataset for 2D/3D image registration evaluation

被引:4
|
作者
Pawiro, Supriyanto [1 ]
Markelj, Primoz [2 ]
Gendrin, Christelle [1 ]
Figl, Michael [1 ]
Stock, Markus [3 ]
Bloch, Christoph [1 ]
Weber, Christoph [1 ]
Unger, Ewald [1 ]
Noebauer, Iris [4 ]
Kainberger, Franz [4 ]
Bergmeister, Helga [3 ]
Georg, Dietmar [3 ]
Bergmann, Helmar [1 ]
Birkfellner, Wolfgang [1 ]
机构
[1] Med Univ Vienna, Ctr Biomed Engn & Phys, Vienna, Austria
[2] Univ Ljubljana, Fac Elect Engn, Ljubljana, Slovenia
[3] Med Univ, Univ Clin Radiat Oncol, Div Med Phys, Vienna, Austria
[4] Med Univ Vienna, Univ Clin Radiat Oncol, Div Ostepradol, Vienna, Austria
关键词
Gold Standard; Image Registration; Image Guidance; Radiotherapy; X-RAY IMAGES; AUTOMATIC REGISTRATION; PORTAL IMAGES; VOLUMETRIC CT; ACCURACY; MR;
D O I
10.1117/12.844488
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this paper, we propose a new gold standard data set for the validation of 2D/3D image registration algorithms for image guided radiotherapy. A gold standard data set was calculated using a pig head with attached fiducial markers. We used several imaging modalities common in diagnostic imaging or radiotherapy which include 64-slice computed tomography (CT), magnetic resonance imaging (MRI) using T1, T2 and proton density (PD) sequences, and cone beam CT (CBCT) imaging data. Radiographic data were acquired using kilovoltage (kV) and megavoltage (MV) imaging techniques. The image information reflects both anatomy and reliable fiducial marker information, and improves over existing data sets by the level of anatomical detail and image data quality. The markers of three dimensional (3D) and two dimensional (2D) images were segmented using Analyze 9.0 (AnalyzeDirect, Inc) and an in-house software. The projection distance errors (PDE) and the expected target registration errors (TRE) over all the image data sets were found to be less than 1.7 mm and 1.3 mm, respectively. The gold standard data set, obtained with state-of-the-art imaging technology, has the potential to improve the validation of 2D/3D registration algorithms for image guided therapy.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Evaluation of an efficient GPU implementation of digitally reconstructed radiographs in 3D/2D image registration
    Zhang, Chong
    Villa-Uriol, Maria-Cruz
    Frangi, Alejandro F.
    [J]. MEDICAL IMAGING 2010: IMAGE PROCESSING, 2010, 7623
  • [22] FAUST: Dataset and evaluation for 3D mesh registration
    Bogo, Federica
    Romero, Javier
    Loper, Matthew
    Black, Michael J.
    [J]. 2014 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2014, : 3794 - 3801
  • [23] Backhoe 3D "Gold Standard" image
    Gorham, L
    Naidu, KD
    Majumder, U
    Minardi, MA
    [J]. Algorithms for Synthetic Aperture Radar Imagery XII, 2005, 5808 : 64 - 71
  • [24] A New Image Database for 3D/2D Registration Based on the Visible Human Data Set
    Markelj, Primoz
    Likar, Bostjan
    Pernus, Franjo
    [J]. BIOMEDICAL IMAGE REGISTRATION, 2010, 6204 : 151 - 160
  • [25] Evaluation of the Rotational Alignment Accuracy and Error Using 3D/3D, 2D/3D and 3D Surface Registration
    Kuo, H.
    Ballangrud, A.
    Li, G.
    Lovelock, D.
    Wolthuis, B.
    Della-Biancia, C.
    Berry, S.
    Hunt, M.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E307 - E308
  • [26] 2D/3D registration of multiple bones
    Ma, Burton
    Stewart, James
    Pichora, David
    Ellis, Randy
    Abolmaesumi, Purang
    [J]. 2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 860 - 863
  • [27] Deep Iterative 2D/3D Registration
    Jaganathan, Srikrishna
    Wang, Jian
    Borsdorf, Anja
    Shetty, Karthik
    Maier, Andreas
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2021, PT IV, 2021, 12904 : 383 - 392
  • [28] Evaluating 2D/3D registration accuracy
    LaRose, D
    Bayouth, J
    Kanade, T
    [J]. CARS 2000: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2000, 1214 : 147 - 152
  • [29] Evaluation of similarity measures and optimization methods for 2D/3D rigid registration in image guided interventions
    Zhang, Ran
    Wang, Lei
    Xia, Wei
    Gao, Xin
    [J]. 2013 INTERNATIONAL CONFERENCE ON COMPUTER SCIENCES AND APPLICATIONS (CSA), 2013, : 623 - 626
  • [30] Frameworks for Multi-core Architectures: A Comprehensive Evaluation Using 2D/3D Image Registration
    Membarth, Richard
    Hannig, Frank
    Teich, Juergen
    Koerner, Mario
    Eckert, Wieland