Backhoe 3D "Gold Standard" image

被引:9
|
作者
Gorham, L [1 ]
Naidu, KD [1 ]
Majumder, U [1 ]
Minardi, MA [1 ]
机构
[1] USAF, Res Lab, Sensors Directorate, ATR Div, Wright Patterson AFB, OH 45433 USA
关键词
synthetic aperture radar; visualization;
D O I
10.1117/12.609907
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
ViSUAI-D (VIsual Sar Using ALI Dimensions), a 2004 DARPA/IXO seedling effort, is developing a capability for reliable hi-h confidence ID from standoff ranges. Recent conflicts have demonstrated that the warfighter would greatly benefit from the ability to ID targets beyond visual and electro-optical ranges[1]. Forming optical-quality SAR images while exploiting full polarization, wide angles, and large bandwidth would be key evidence such a capability is achievable. Using data generated by the Chi patch EM scattering code, ViSUAI-D investigates all degrees of freedom available to the radar designer, including 6 GHz bandwidth, full polarization and angle sampling over 2 pi steradians (upper hemisphere), in order to produce a "literal" image or representation of the target. This effort includes the generation of a "Gold Standard" image that can be produced at Chi-band utilizing all available target data. This "Gold Standard" image of the backhoe will serve as a test bed for future more relevant military targets and their image development. The seedling, team produced a public release data which was released at the 2004 SPIE conference, as well as a 3D "Gold Standard" backhoe image using a 3D image formation algorithm. This paper describes the full backhoe data set, the image formation algorithm, the visualization process and the resulting image.
引用
下载
收藏
页码:64 / 71
页数:8
相关论文
共 50 条
  • [1] A new gold-standard dataset for 2D/3D image registration evaluation
    Pawiro, Supriyanto
    Markelj, Primoz
    Gendrin, Christelle
    Figl, Michael
    Stock, Markus
    Bloch, Christoph
    Weber, Christoph
    Unger, Ewald
    Noebauer, Iris
    Kainberger, Franz
    Bergmeister, Helga
    Georg, Dietmar
    Bergmann, Helmar
    Birkfellner, Wolfgang
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [2] 3D contrast enhanced ultrasound (3D CEUS) for endoleak detection after EVAR - a new gold standard?
    Lowe, C.
    Abbas, A.
    Armitage, J.
    Sedgwick, N.
    Smith, L.
    Rogers, S.
    Ghosh, J.
    McCollum, C. N.
    BRITISH JOURNAL OF SURGERY, 2015, 102 : 9 - 9
  • [3] 3D pulmonary CT image registration with a standard lung atlas
    Zhang, L
    Reinhardt, JM
    MEDICAL IMAGING 2000: PHYSIOLOGY AND FUNCTION FORM MULTIDIMENSIONAL IMAGES, 2000, 3978 : 67 - 77
  • [4] Single Image 3D Without a Single 3D Image
    Fouhey, David F.
    Hussain, Wajahat
    Gupta, Abhinav
    Hebert, Martial
    2015 IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV), 2015, : 1053 - 1061
  • [5] Will 3D USG substitute the gold standard diagnostic tests of uterine anomalies?
    Nanjundan, P.
    Pandian, R.
    Rajesh, H.
    Govindarajan, M.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2014, 121 : 45 - 46
  • [6] Clinical Assessment of Breast Volume: Can 3D Imaging Be the Gold Standard?
    Killaars, Renee C.
    Preuss, Myriam L. G.
    de Vos, Nathalie J. P.
    van Berlo, Camille C. J. L. Y.
    Lobbes, Marc B., I
    van der Hulst, Rene R. W. J.
    Piatkowski, Andrzej A.
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2020, 8 (11) : E3236
  • [7] Image transmission and contents technology: Production of 3D standard test contents
    Kimura, Kazuhiro
    Arakawa, Yoshiki
    Oi, Ryutaro
    Yamamoto, Kenji
    Journal of the National Institute of Information and Communications Technology, 2010, 57 (1-2): : 169 - 193
  • [8] 3D rotational angiography: The new gold standard in the detection of additional intracranial aneurysms
    van Rooij, W. J.
    Sprengers, M. E.
    de Gast, A. N.
    Peluso, J. P. P.
    Sluzewski, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (05) : 976 - 979
  • [9] Device and methods for "gold standard" registration of clinical 3D and 2D cerebral angiograms
    Madan, Hennadii
    Likar, Bostjan
    Pernus, Franjo
    Spiclin, Ziga
    MEDICAL IMAGING 2015: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2015, 9415
  • [10] Validation for 2D/3D registration I: A new gold standard data set
    Pawiro, S. A.
    Markelj, P.
    Pernus, F.
    Gendrin, C.
    Figl, M.
    Weber, C.
    Kainberger, F.
    Noebauer-Huhmann, I.
    Bergmeister, H.
    Stock, M.
    Georg, D.
    Bergmann, H.
    Birkfellner, W.
    MEDICAL PHYSICS, 2011, 38 (03) : 1481 - 1490