A new gold-standard dataset for 2D/3D image registration evaluation

被引:4
|
作者
Pawiro, Supriyanto [1 ]
Markelj, Primoz [2 ]
Gendrin, Christelle [1 ]
Figl, Michael [1 ]
Stock, Markus [3 ]
Bloch, Christoph [1 ]
Weber, Christoph [1 ]
Unger, Ewald [1 ]
Noebauer, Iris [4 ]
Kainberger, Franz [4 ]
Bergmeister, Helga [3 ]
Georg, Dietmar [3 ]
Bergmann, Helmar [1 ]
Birkfellner, Wolfgang [1 ]
机构
[1] Med Univ Vienna, Ctr Biomed Engn & Phys, Vienna, Austria
[2] Univ Ljubljana, Fac Elect Engn, Ljubljana, Slovenia
[3] Med Univ, Univ Clin Radiat Oncol, Div Med Phys, Vienna, Austria
[4] Med Univ Vienna, Univ Clin Radiat Oncol, Div Ostepradol, Vienna, Austria
关键词
Gold Standard; Image Registration; Image Guidance; Radiotherapy; X-RAY IMAGES; AUTOMATIC REGISTRATION; PORTAL IMAGES; VOLUMETRIC CT; ACCURACY; MR;
D O I
10.1117/12.844488
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this paper, we propose a new gold standard data set for the validation of 2D/3D image registration algorithms for image guided radiotherapy. A gold standard data set was calculated using a pig head with attached fiducial markers. We used several imaging modalities common in diagnostic imaging or radiotherapy which include 64-slice computed tomography (CT), magnetic resonance imaging (MRI) using T1, T2 and proton density (PD) sequences, and cone beam CT (CBCT) imaging data. Radiographic data were acquired using kilovoltage (kV) and megavoltage (MV) imaging techniques. The image information reflects both anatomy and reliable fiducial marker information, and improves over existing data sets by the level of anatomical detail and image data quality. The markers of three dimensional (3D) and two dimensional (2D) images were segmented using Analyze 9.0 (AnalyzeDirect, Inc) and an in-house software. The projection distance errors (PDE) and the expected target registration errors (TRE) over all the image data sets were found to be less than 1.7 mm and 1.3 mm, respectively. The gold standard data set, obtained with state-of-the-art imaging technology, has the potential to improve the validation of 2D/3D registration algorithms for image guided therapy.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Extended global optimization strategy for rigid 2D/3D image registration
    Kubias, Alexander
    Deinzer, Frank
    Feldmann, Tobias
    Paulus, Dietrich
    [J]. COMPUTER ANALYSIS OF IMAGES AND PATTERNS, PROCEEDINGS, 2007, 4673 : 759 - 767
  • [42] 3D/2D image registration by image transformation descriptors (ITDs) for thoracic aorta imaging
    Lubniewski, Pawel J.
    Sarry, Laurent
    Miguel, Bruno
    Lohou, Christophe
    [J]. THREE-DIMENSIONAL IMAGE PROCESSING (3DIP) AND APPLICATIONS 2013, 2013, 8650
  • [43] Image scanners: 2D and 3D
    Handley, R.
    [J]. Advanced Imaging, 2001, 16 (07) : 28 - 33
  • [44] 2D and 3D image processing
    2D- und 3D-Bildverarbeitung
    [J]. Materialpruefung/Materials Testing, 2001, 43 (05):
  • [45] The agreement between 3D, standard 2D and triplane 2D speckle tracking: Effects of image quality and 3D volume rate
    Trache T.
    Stöbe S.
    Tarr A.
    Pfeiffer D.
    Hagendorff A.
    [J]. Echo Research & Practice, 2014, 1 (2): : 71 - 83
  • [46] New television with 2D/3D image conversion technologies
    Okino, T
    Murata, H
    Taima, K
    Iinuma, T
    Oketani, K
    [J]. STEREOSCOPIC DISPLAYS AND VIRTUAL REALITY SYSTEMS III, 1996, 2653 : 96 - 103
  • [47] Registration of 3D cerebral vessels with 2D digital angiograms: Clinical evaluation
    Bullitt, E
    Liu, A
    Aylward, SR
    Coffey, C
    Stone, J
    Mukherji, SK
    Muller, KE
    Pizer, SM
    [J]. ACADEMIC RADIOLOGY, 1999, 6 (09) : 539 - 546
  • [48] Evaluation of breast tissue characterization by ultrasound computer tomography using a 2D/3D image registration with mammograms
    Hopp, Torsten
    Stromboni, Aurelien
    Duric, Neb
    Ruiter, Nicole V.
    [J]. 2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 643 - 646
  • [49] 2D/3D registration of freehand SPECT and planar scintigraphy for clinical evaluation of 3D thyroid scintigraphy
    Wendler, T.
    Feng, X.
    Herrmann, K.
    Lasser, T.
    Traub, J.
    Ziegler, S. I.
    Navab, N.
    Buck, A. K.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S281 - S281
  • [50] 2D/3D registration of freehand SPECT and planar scintigraphy for clinical evaluation of 3D thyroid scintigraphy
    Feng, X.
    Szajkowska, K.
    Lasser, T.
    Ziegler, S. I.
    Navab, N.
    Wendler, T.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 737 - 740