Experimental investigation of the performance of a reverse osmosis desalination unit under full- and part-load operation

被引:33
|
作者
Dimitriou, Evangelos [1 ]
Mohamed, Essam Sh. [1 ]
Kyriakarakos, George [1 ]
Papadakis, George [1 ]
机构
[1] Agr Univ Athens, Dept Nat Resources & Agr Engn, GR-11855 Athens, Greece
关键词
Microgrid; Variable operating conditions; Polygeneration; Sea water reverse osmosis desalination; ENERGY MANAGEMENT-SYSTEM; AUTONOMOUS POLYGENERATION MICROGRIDS; BATTERIES; RECOVERY; WATER;
D O I
10.1080/19443994.2014.933623
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Sea water reverse osmosis (SWRO) desalination constitutes a successful technology for covering the potable water needs of islands and coastal regions. SWRO units can be combined with renewable energy technologies such as photovoltaic and wind generators. Conventional small scale SWRO units are not often combined with energy recovery devices; however, these devices can decrease drastically the energy consumption of the SWRO units. Furthermore, in the literature there are references which prove that the operation of a desalination unit in part-load conditions can result in lower specific energy consumption compared to full-load operation. This paper presents the simulation and the experimental investigation under full- and part-load conditions of an existing SWRO desalination unit (50 mS/cm feed water) in order for the desalination unit to be optimally utilized in a polygeneration microgrid topology which uses advanced energy management algorithms. The experimental operation of the SWRO Unit in part-load conditions is achieved by varying the speed of the motor-pump assembly, the pressure and the flow rate of the feed water. During the evaluation of the measurements result, an optimum operating window in the range of 40-57 bar was drawn regarding the operation of the SWRO desalination unit in part- and full-load conditions. More specifically, in this pressure range the average value of fresh water production was 60 L/h with an acceptable fresh water electrical conductivity of 550 mu S/cm, and with a specific energy consumption range from 6.1 to 7.7 kWh/m(3). With these results the operational parameters of the polygeneration microgrid energy management system can be optimized.
引用
收藏
页码:3170 / 3178
页数:9
相关论文
共 50 条
  • [41] Effect of intermittent operation modes on performance of reverse osmosis (RO) membrane in desalination and water treatment
    Yang, Heungsik
    Choi, Jihyeok
    Choi, Yongjun
    Lee, Sangho
    MEMBRANE AND WATER TREATMENT, 2022, 13 (01): : 39 - 49
  • [42] An experimental comparative study of the technical and economic performance of a small reverse osmosis desalination system equipped with an hydraulic energy recovery unit
    Mohamed, Essam Sh.
    Papadakis, G.
    Mathioulakis, E.
    Belessiotis, V.
    DESALINATION, 2006, 194 (1-3) : 239 - 250
  • [43] STABILIZING THE CHARACTERISTICS OF A PUMP-TURBINE IN THE RANGE BETWEEN TURBINE PART-LOAD AND REVERSE PUMPING OPERATION.
    Klemm, Dieter
    Voith Research and Construction, 1982, 28 e : 1 - 2
  • [44] Experimental evaluation and semi-empirical modeling of a small-capacity reverse osmosis desalination unit
    Haluch, Vanessa
    Zanoelo, Everton F.
    Hermes, Christian J. L.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2017, 122 : 243 - 253
  • [45] Simulation of Full and Part-Load Performance Deterioration of Industrial Two-Shaft Gas Turbine
    Mohammadi, E.
    Montazeri-Gh, M.
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2014, 136 (09):
  • [46] Nuclear-Powered Reverse Osmosis Desalination Unit Performance Improvement Using Six Sigma and Desalination Economic Evaluation Model
    Sabry, Amr M.
    Elshahat, Ayah
    Nagla, Tarek F. F.
    Agamy, Saeed
    JOURNAL OF WATER CHEMISTRY AND TECHNOLOGY, 2022, 44 (06) : 403 - 414
  • [47] Nuclear-Powered Reverse Osmosis Desalination Unit Performance Improvement Using Six Sigma and Desalination Economic Evaluation Model
    A. Amr M. Sabry
    Ayah Elshahat
    Tarek F. Nagla
    Saeed Agamy
    Journal of Water Chemistry and Technology, 2022, 44 : 403 - 414
  • [48] Performance investigation of a reverse osmosis desalination system powered by solar dish-Stirling engine
    Geng, Donghan
    Cui, Jiedong
    Fan, Lijun
    ENERGY REPORTS, 2021, 7 (07) : 3844 - 3856
  • [49] Experimental performance evaluation of battery powered small-scale reverse osmosis desalination system
    Ahmed, Mohammed Riaz
    Elshafei, Moustafa
    Sheikh, Anwar K.
    Saif, Abdul-Wahid A.
    2014 11TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS & DEVICES (SSD), 2014,
  • [50] Theoretical performance prediction of a reverse osmosis desalination membrane element under variable operating conditions
    Dimitriou, Evangelos
    Boutikos, Panagiotis
    Mohamed, Essam Sh.
    Koziel, Slawomir
    Papadakis, George
    DESALINATION, 2017, 419 : 70 - 78