Experimental investigation of the performance of a reverse osmosis desalination unit under full- and part-load operation

被引:33
|
作者
Dimitriou, Evangelos [1 ]
Mohamed, Essam Sh. [1 ]
Kyriakarakos, George [1 ]
Papadakis, George [1 ]
机构
[1] Agr Univ Athens, Dept Nat Resources & Agr Engn, GR-11855 Athens, Greece
关键词
Microgrid; Variable operating conditions; Polygeneration; Sea water reverse osmosis desalination; ENERGY MANAGEMENT-SYSTEM; AUTONOMOUS POLYGENERATION MICROGRIDS; BATTERIES; RECOVERY; WATER;
D O I
10.1080/19443994.2014.933623
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Sea water reverse osmosis (SWRO) desalination constitutes a successful technology for covering the potable water needs of islands and coastal regions. SWRO units can be combined with renewable energy technologies such as photovoltaic and wind generators. Conventional small scale SWRO units are not often combined with energy recovery devices; however, these devices can decrease drastically the energy consumption of the SWRO units. Furthermore, in the literature there are references which prove that the operation of a desalination unit in part-load conditions can result in lower specific energy consumption compared to full-load operation. This paper presents the simulation and the experimental investigation under full- and part-load conditions of an existing SWRO desalination unit (50 mS/cm feed water) in order for the desalination unit to be optimally utilized in a polygeneration microgrid topology which uses advanced energy management algorithms. The experimental operation of the SWRO Unit in part-load conditions is achieved by varying the speed of the motor-pump assembly, the pressure and the flow rate of the feed water. During the evaluation of the measurements result, an optimum operating window in the range of 40-57 bar was drawn regarding the operation of the SWRO desalination unit in part- and full-load conditions. More specifically, in this pressure range the average value of fresh water production was 60 L/h with an acceptable fresh water electrical conductivity of 550 mu S/cm, and with a specific energy consumption range from 6.1 to 7.7 kWh/m(3). With these results the operational parameters of the polygeneration microgrid energy management system can be optimized.
引用
收藏
页码:3170 / 3178
页数:9
相关论文
共 50 条
  • [31] Operation window and part-load performance study of a syngas fired gas turbine
    He, Fen
    Li, Zheng
    Liu, Pei
    Ma, Linwei
    Pistikopoulos, Efstratios N.
    APPLIED ENERGY, 2012, 89 (01) : 133 - 141
  • [32] Exit blade geometry and part-load performance of small axial flow propeller turbines: An experimental investigation
    Singh, Punit
    Nestmann, Franz
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2010, 34 (06) : 798 - 811
  • [33] Performance Analysis of a Full-Scale Desalination Plant with Reverse Osmosis Membranes for Irrigation
    Leon, Federico
    Ramos, Alejandro
    MEMBRANES, 2021, 11 (10)
  • [34] Evaluation of the performance of water-cooled VRF system for heat exchanger geometry under part-load operation
    Choi, Jiyeon
    Oh, Been
    Na, Sangkyung
    Min, Byeongchae
    Park, Yeseul
    Choi, Gyungmin
    APPLIED THERMAL ENGINEERING, 2022, 215
  • [35] Investigation of different operational strategies for the variable operation of a simple reverse osmosis unit
    Pohl, Robert
    Kaltschmitt, Martin
    Hollaender, Robert
    DESALINATION, 2009, 249 (03) : 1280 - 1287
  • [36] Evaluation of the performance of water-cooled VRF system for heat exchanger geometry under part-load operation
    Choi, Jiyeon
    Oh, Been
    Na, Sangkyung
    Min, Byeongchae
    Park, Yeseul
    Choi, Gyungmin
    Applied Thermal Engineering, 2022, 215
  • [37] Heat transfer modelling of semi-suspension biomass fired industrial watertube boiler at full- and part-load using CFD
    Laubscher, Ryno
    van der Merwe, Schalk
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 25
  • [38] Experimental assessment of pine wood chips gasification at steady and part-load performance
    Soares, Joao
    Oliveira, Armando C.
    BIOMASS & BIOENERGY, 2020, 139
  • [39] Ten years operation of ultrafiltration and reverse osmosis in the Limassol Desalination Plant in Cyprus - challenges and performance
    Macia, Maria angeles Perez
    Campos, Lorena Barbera
    Gilabert-Oriol, Guillem
    Koutsakos, Erineos
    Priel, Menahem
    Ram, Carmit
    DESALINATION AND WATER TREATMENT, 2023, 309 : 34 - 38
  • [40] Performance investigation of a novel free piston Stirling pump for reverse osmosis desalination systems
    Geng, Donghan
    Qu, Xingchuang
    Zhang, Yunlong
    Li, Longfei
    Zhang, Yongkang
    DESALINATION, 2024, 587