Experimental investigation of the performance of a reverse osmosis desalination unit under full- and part-load operation

被引:33
|
作者
Dimitriou, Evangelos [1 ]
Mohamed, Essam Sh. [1 ]
Kyriakarakos, George [1 ]
Papadakis, George [1 ]
机构
[1] Agr Univ Athens, Dept Nat Resources & Agr Engn, GR-11855 Athens, Greece
关键词
Microgrid; Variable operating conditions; Polygeneration; Sea water reverse osmosis desalination; ENERGY MANAGEMENT-SYSTEM; AUTONOMOUS POLYGENERATION MICROGRIDS; BATTERIES; RECOVERY; WATER;
D O I
10.1080/19443994.2014.933623
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Sea water reverse osmosis (SWRO) desalination constitutes a successful technology for covering the potable water needs of islands and coastal regions. SWRO units can be combined with renewable energy technologies such as photovoltaic and wind generators. Conventional small scale SWRO units are not often combined with energy recovery devices; however, these devices can decrease drastically the energy consumption of the SWRO units. Furthermore, in the literature there are references which prove that the operation of a desalination unit in part-load conditions can result in lower specific energy consumption compared to full-load operation. This paper presents the simulation and the experimental investigation under full- and part-load conditions of an existing SWRO desalination unit (50 mS/cm feed water) in order for the desalination unit to be optimally utilized in a polygeneration microgrid topology which uses advanced energy management algorithms. The experimental operation of the SWRO Unit in part-load conditions is achieved by varying the speed of the motor-pump assembly, the pressure and the flow rate of the feed water. During the evaluation of the measurements result, an optimum operating window in the range of 40-57 bar was drawn regarding the operation of the SWRO desalination unit in part- and full-load conditions. More specifically, in this pressure range the average value of fresh water production was 60 L/h with an acceptable fresh water electrical conductivity of 550 mu S/cm, and with a specific energy consumption range from 6.1 to 7.7 kWh/m(3). With these results the operational parameters of the polygeneration microgrid energy management system can be optimized.
引用
收藏
页码:3170 / 3178
页数:9
相关论文
共 50 条
  • [21] Operation and performance of reverse osmosis modules in large sea water desalination plants
    Tanaka, S
    Nita, K
    Sekino, M
    NUCLEAR DESALINATION OF SEA WATER, 1997, : 339 - 347
  • [22] The exergetic efficiency as a performance evaluation tool in reverse osmosis desalination plants in operation
    Blanco-Marigorta, A. M.
    Lozano-Medina, A.
    Marcos, J. D.
    DESALINATION, 2017, 413 : 19 - 28
  • [23] Experimental investigation of saturated fogging and overspray influence on part-load micro gas turbine performance
    Barakat, Elsayed
    Jin, Tai
    Tong, Xiaokang
    Ma, Chengbiao
    Wang, Gaofeng
    APPLIED THERMAL ENGINEERING, 2023, 219
  • [24] Carbon Capture Performance Assessment Applied to Combined Cycle Gas Turbine Under Part-Load Operation
    Verhaeghe, Antoine
    Dubois, Lionel
    Bricteux, Laurent
    Thomas, Diane
    Blondeau, Julien
    De Paepe, Ward
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2023, 145 (04):
  • [25] CARBON CAPTURE PERFORMANCE ASSESSMENT APPLIED TO COMBINED CYCLE GAS TURBINE UNDER PART-LOAD OPERATION
    Verhaeghe, Antoine
    Dubois, Lionel
    Bricteux, Laurent
    Thomas, Diane
    Blondeau, Julien
    De Paepe, Ward
    PROCEEDINGS OF ASME TURBO EXPO 2022: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2022, VOL 4, 2022,
  • [26] NUMERICAL AND EXPERIMENTAL INVESTIGATION OF PERFORMANCE AND RELIABILITY IN NEW REVERSE OSMOSIS SEAWATER DESALINATION HIGH PRESSURE PUMP
    Ye, Xiao-yan
    Hu, Jing-ning
    Wang, Jing
    Feng, Yao-ning
    Jiang, Wei
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 7B, 2014,
  • [27] Design and experimental performance of brackish water reverse osmosis desalination unit powered by 2 kW photovoltaic system
    Alghoul, M. A.
    Poovanaesvaran, P.
    Mohammed, M. H.
    Fadhil, A. M.
    Muftah, A. F.
    Alkilani, M. M.
    Sopian, K.
    RENEWABLE ENERGY, 2016, 93 : 101 - 114
  • [28] Power Quality Observations for Solar Photovoltaic Inverters under Part-load Operation
    Murray, Kevin
    McLorn, Gareth
    Morrow, John
    Best, Robert
    McLoone, Sean
    Liu, Amy
    2017 52ND INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2017,
  • [29] AN EXPERIMENTAL INVESTIGATION OF HYDROGEN FUMIGATION IN A SMALL DIRECT-INJECTION DIESEL ENGINE DURING PART-LOAD OPERATION
    Marin, William E.
    Wiese, Daniel P.
    Erickson, Paul A.
    PROCEEDINGS OF THE ASME INTERNAL COMBUSTION ENGINE DIVISION FALL TECHNICAL CONFERENCE (ICEF), 2011, : 339 - 348
  • [30] Experimental investigation of a reverse osmosis desalination system directly powered by wave energy
    Mi, Jia
    Wu, Xian
    Capper, Joseph
    Li, Xiaofan
    Shalaby, Ahmed
    Wang, Ruoyu
    Lin, Shihong
    Hajj, Muhammad
    Zuo, Lei
    APPLIED ENERGY, 2023, 343