Experimental investigation of the performance of a reverse osmosis desalination unit under full- and part-load operation

被引:33
|
作者
Dimitriou, Evangelos [1 ]
Mohamed, Essam Sh. [1 ]
Kyriakarakos, George [1 ]
Papadakis, George [1 ]
机构
[1] Agr Univ Athens, Dept Nat Resources & Agr Engn, GR-11855 Athens, Greece
关键词
Microgrid; Variable operating conditions; Polygeneration; Sea water reverse osmosis desalination; ENERGY MANAGEMENT-SYSTEM; AUTONOMOUS POLYGENERATION MICROGRIDS; BATTERIES; RECOVERY; WATER;
D O I
10.1080/19443994.2014.933623
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Sea water reverse osmosis (SWRO) desalination constitutes a successful technology for covering the potable water needs of islands and coastal regions. SWRO units can be combined with renewable energy technologies such as photovoltaic and wind generators. Conventional small scale SWRO units are not often combined with energy recovery devices; however, these devices can decrease drastically the energy consumption of the SWRO units. Furthermore, in the literature there are references which prove that the operation of a desalination unit in part-load conditions can result in lower specific energy consumption compared to full-load operation. This paper presents the simulation and the experimental investigation under full- and part-load conditions of an existing SWRO desalination unit (50 mS/cm feed water) in order for the desalination unit to be optimally utilized in a polygeneration microgrid topology which uses advanced energy management algorithms. The experimental operation of the SWRO Unit in part-load conditions is achieved by varying the speed of the motor-pump assembly, the pressure and the flow rate of the feed water. During the evaluation of the measurements result, an optimum operating window in the range of 40-57 bar was drawn regarding the operation of the SWRO desalination unit in part- and full-load conditions. More specifically, in this pressure range the average value of fresh water production was 60 L/h with an acceptable fresh water electrical conductivity of 550 mu S/cm, and with a specific energy consumption range from 6.1 to 7.7 kWh/m(3). With these results the operational parameters of the polygeneration microgrid energy management system can be optimized.
引用
收藏
页码:3170 / 3178
页数:9
相关论文
共 50 条
  • [1] The Effect of Physical Faults on a Three-Shaft Gas Turbine Performance at Full- and Part-Load Operation
    Salilew, Waleligne Molla
    Karim, Zainal Ambri Abdul
    Lemma, Tamiru Alemu
    Fentaye, Amare Desalegn
    Kyprianidis, Konstantinos G.
    SENSORS, 2022, 22 (19)
  • [2] Periodic operation of a reverse osmosis water desalination unit
    Al-Bastaki, NM
    Abbas, A
    SEPARATION SCIENCE AND TECHNOLOGY, 1998, 33 (16) : 2531 - 2540
  • [3] Experimental investigation on the performance of a small reverse osmosis unit
    Elsayed, M.
    Refaey, H. A.
    Abdellatif, O. E.
    Sakr, R. Y.
    Afify, R. I.
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2018, 40 (04)
  • [4] Experimental investigation on the performance of a small reverse osmosis unit
    M. Elsayed
    H. A. Refaey
    O. E. Abdellatif
    R. Y. Sakr
    R. I. Afify
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2018, 40
  • [5] Theoretical and experimental investigation on the performance of screw refrigeration compressor under part-load conditions
    Chen, Wenqing
    Xing, Ziwen
    Tang, Hao
    Wu, Huagen
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (04): : 1141 - 1150
  • [6] UNSTEADY STATE OPERATION OF A REVERSE-OSMOSIS DESALINATION UNIT
    LISING, ER
    ALWARD, R
    DESALINATION, 1972, 11 (03) : 261 - 268
  • [7] Experimental Investigation of Solar Powered Reverse Osmosis Desalination
    Gebray, Petros
    Kebedom, Ashenafi
    Filli, Fana
    MOMONA ETHIOPIAN JOURNAL OF SCIENCE, 2015, 7 (02): : 164 - 175
  • [8] Full load and part-load performance prediction for integrated SOFC and microturbine systems
    Campanari, S
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2000, 122 (02): : 239 - 246
  • [9] Improvement in part-load performance of a manifold injected spark ignition engine - an experimental investigation
    Purushothama, H. R.
    Mallikarjuna, J. M.
    Ganesan, V.
    INDIAN JOURNAL OF ENGINEERING AND MATERIALS SCIENCES, 2010, 17 (01) : 7 - 12
  • [10] Performance evaluation and mathematical modeling of reverse osmosis membrane desalination unit
    Alzahmi, Ahmed
    Alswat, Mohammed
    El-Askary, W. A.
    Ramzy, Khaled
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, : 15143 - 15158