Wearable Piezoelectric-Based System for Continuous Beat-to-Beat Blood Pressure Measurement

被引:54
|
作者
Wang, Ting-Wei [1 ]
Lin, Shien-Fong [1 ,2 ,3 ]
机构
[1] Natl Chiao Tung Univ, Dept Elect & Comp Engn, Coll Elect & Comp Engn, Hsinchu 30010, Taiwan
[2] Natl Chiao Tung Univ, Inst Biomed Engn, Coll Elect & Comp Engn, Hsinchu 30010, Taiwan
[3] Indiana Univ Sch Med, Krannert Inst Cardiol, Indianapolis, IN 46202 USA
关键词
continuous blood pressure; piezoelectric sensor; wearable device; PULSE TRANSIT-TIME;
D O I
10.3390/s20030851
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Non-invasive continuous blood pressure measurement is an emerging issue that potentially can be applied to cardiovascular disease monitoring and prediction. Recently, many groups have proposed the pulse transition time (PTT) method to estimate blood pressure for long-term monitoring. However, the PTT-based methods for blood pressure estimation are limited by non-specific estimation models and require multiple calibrations. This study aims to develop a low-cost wearable piezoelectric-based system for continuous beat-to-beat blood pressure measurement. The pressure change in the radial artery was extracted by systolic and diastolic feature points in pressure pulse wave (PPW) and the pressure sensitivity of the sensor. The proposed system showed a reliable accuracy of systolic blood pressure (SBP) (mean absolute error (MAE) +/- standard deviation (SD) 1.52 +/- 0.30 mmHg) and diastolic blood pressure (DBP, MAE +/- SD 1.83 +/- 0.50), and its performance agreed with standard criteria of MAE within 5 mmHg and SD within +/- 8 mmHg. In conclusion, this study successfully developed a low-cost, high-accuracy piezoelectric-based system for continuous beat-to-beat SBP and DBP measurement without multiple calibrations and complex regression analysis. The system is potentially suitable for continuous, long-term blood pressure-monitoring applications.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] ADOPTION OF CONTINUOUS BEAT-TO-BEAT NOCTURNAL BLOOD PRESSURE MEASUREMENT IN AMBULATORY BLOOD PRESSURE MONITORING
    Estrada, Sebastian
    Kwon, Younghoon
    Baruch, Martin
    Harrison, Elizabeth
    Williams, Ronald
    Cho, Yeilim
    Gerdt, David
    Bonner, Heather
    Mazimba, Sula
    Berry, Richard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1893 - 1893
  • [2] Soft Wearable Pressure Sensors for Beat-to-Beat Blood Pressure Monitoring
    Kim, Joshua
    Chou, En-Fan
    Le, Jamie
    Wong, Sabrina
    Chu, Michael
    Khine, Michelle
    ADVANCED HEALTHCARE MATERIALS, 2019, 8 (13)
  • [3] A Wireless Wearable Sensor Patch for the Real-Time Estimation of Continuous Beat-to-Beat Blood Pressure
    Qiu, Chunkai
    Wu, Taiyang
    Redoute, Jean-Michel
    Yuce, Mehmet Rasit
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 6842 - 6845
  • [4] Effect of peripheral vasoconstriction on the beat-to-beat measurement of finger blood pressure
    Raamat, R
    Talts, J
    Jagomägi, K
    Kingisepp, PH
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2223 - 2226
  • [5] Non-contact Beat-to-beat Blood Pressure Measurement Using Continuous Wave Doppler Radar
    Zhao, Heng
    Gu, Xu
    Hong, Hong
    Li, Yusheng
    Zhu, Xiaohua
    Li, Changzhi
    2018 IEEE/MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM - IMS, 2018, : 1413 - 1415
  • [6] SLEEP QUALITY AND CONTINUOUS, NONINVASIVE BEAT-TO-BEAT BLOOD-PRESSURE RECORDING
    VANDEBORNE, P
    NGUYEN, H
    LINKOWSKI, P
    DEGAUTE, JP
    JOURNAL OF HYPERTENSION, 1993, 11 (12) : 1423 - 1427
  • [7] A Probabilistic Beat-to-Beat Filtering Model for Continuous and Accurate Blood Pressure Estimation
    Chen, Zehua
    Dees, Bruno Scalzo
    Mandic, Danilo P.
    2020 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2020,
  • [8] Beat-to-beat ambulatory blood pressure estimation based on random forest
    He, Rui
    Huang, Zhi-Pei
    Ji, Lian-Ying
    Wu, Jian-Kang
    Li, Huihui
    Zhang, Zhi-Qiang
    2016 IEEE 13TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2016, : 194 - 198
  • [9] Ambulatory and beat-to-beat blood pressure variability: Are they related?
    Sloan, RP
    Shapiro, PA
    Bagiella, E
    McKinley, PS
    Myers, MM
    Brondolo, EN
    Eichler, B
    PSYCHOSOMATIC MEDICINE, 2001, 63 (01): : 172 - 172
  • [10] Baroreflex failure and beat-to-beat blood pressure variation
    Kishi, Takuya
    HYPERTENSION RESEARCH, 2018, 41 (08) : 547 - 552