Wearable Piezoelectric-Based System for Continuous Beat-to-Beat Blood Pressure Measurement

被引:54
|
作者
Wang, Ting-Wei [1 ]
Lin, Shien-Fong [1 ,2 ,3 ]
机构
[1] Natl Chiao Tung Univ, Dept Elect & Comp Engn, Coll Elect & Comp Engn, Hsinchu 30010, Taiwan
[2] Natl Chiao Tung Univ, Inst Biomed Engn, Coll Elect & Comp Engn, Hsinchu 30010, Taiwan
[3] Indiana Univ Sch Med, Krannert Inst Cardiol, Indianapolis, IN 46202 USA
关键词
continuous blood pressure; piezoelectric sensor; wearable device; PULSE TRANSIT-TIME;
D O I
10.3390/s20030851
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Non-invasive continuous blood pressure measurement is an emerging issue that potentially can be applied to cardiovascular disease monitoring and prediction. Recently, many groups have proposed the pulse transition time (PTT) method to estimate blood pressure for long-term monitoring. However, the PTT-based methods for blood pressure estimation are limited by non-specific estimation models and require multiple calibrations. This study aims to develop a low-cost wearable piezoelectric-based system for continuous beat-to-beat blood pressure measurement. The pressure change in the radial artery was extracted by systolic and diastolic feature points in pressure pulse wave (PPW) and the pressure sensitivity of the sensor. The proposed system showed a reliable accuracy of systolic blood pressure (SBP) (mean absolute error (MAE) +/- standard deviation (SD) 1.52 +/- 0.30 mmHg) and diastolic blood pressure (DBP, MAE +/- SD 1.83 +/- 0.50), and its performance agreed with standard criteria of MAE within 5 mmHg and SD within +/- 8 mmHg. In conclusion, this study successfully developed a low-cost, high-accuracy piezoelectric-based system for continuous beat-to-beat SBP and DBP measurement without multiple calibrations and complex regression analysis. The system is potentially suitable for continuous, long-term blood pressure-monitoring applications.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Beat-to-Beat Blood Pressure Estimation by Photoplethysmography and Its Interpretation
    Fleischhauer, Vincent
    Feldheiser, Aarne
    Zaunseder, Sebastian
    SENSORS, 2022, 22 (18)
  • [22] Continuous beat-to-beat orthostatic blood pressure response in the over 50's in the Irish population
    Fan, Chie Wei
    Finucane, Ciaran
    Cronin, Hilary
    O'Regan, Claire
    Savva, George
    Kenny, Rose Anne
    IRISH JOURNAL OF MEDICAL SCIENCE, 2011, 180 : S354 - S354
  • [23] Pulse transit time-estimated blood pressure: a comparison of beat-to-beat and intermittent measurement
    Hoshide, Satoshi
    Yoshihisa, Akiomi
    Tsuchida, Fumihiro
    Mizuno, Hiroyuki
    Teragawa, Hiroki
    Kasai, Takatoshi
    Koito, Hitoshi
    Ando, Shin-ichi
    Watanabe, Yoshihiko
    Takeishi, Yasuchika
    Kario, Kazuomi
    HYPERTENSION RESEARCH, 2022, 45 (06) : 1001 - 1007
  • [24] BEAT-TO-BEAT INTERVAL MEASUREMENT IN THE ELECTROCARDIOGRAM
    KOELEMAN, ASM
    ROS, HH
    VANDENAKKER, TJ
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1985, 23 (03) : 213 - 219
  • [25] Beat-to-beat oscillations in pulse pressure
    Virtanen, R
    Jula, A
    Kuusela, T
    Airaksinen, J
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2004, 24 (05) : 304 - 309
  • [26] Pulse transit time-estimated blood pressure: a comparison of beat-to-beat and intermittent measurement
    Satoshi Hoshide
    Akiomi Yoshihisa
    Fumihiro Tsuchida
    Hiroyuki Mizuno
    Hiroki Teragawa
    Takatoshi Kasai
    Hitoshi Koito
    Shin-ichi Ando
    Yoshihiko Watanabe
    Yasuchika Takeishi
    Kazuomi Kario
    Hypertension Research, 2022, 45 : 1001 - 1007
  • [27] Blood pressure measurement during cesarean delivery Evaluation of a beat-to-beat noninvasive device (NexfinTM)
    Bobet, Mathieu
    Joachim, Jona
    Gayat, Etienne
    Bonnet, Agnes
    Sievert, Kerstin
    Barnichon, Carole
    Fischler, Marc
    Le Guen, Morgan
    MEDICINE, 2021, 100 (22) : E26129
  • [28] Continuous blood pressure, beat-to-beat stroke volume and R-R interval measurement with the task-force monitor™
    Fortin, J
    Habenbacher, V
    Gruellenberger, R
    Alkan, I
    Hacker, A
    Pfister, P
    Gratze, G
    Wach, P
    Skrabal, F
    JOURNAL OF HYPERTENSION, 2000, 18 : S61 - S62
  • [29] Continuous wavelet transform modulus maxima analysis of the electrocardiogram: Beat characterisation and beat-to-beat measurement
    Legarreta, IR
    Addison, PS
    Reed, MJ
    Grubb, N
    Clegg, GR
    Robertson, CE
    Watson, JN
    INTERNATIONAL JOURNAL OF WAVELETS MULTIRESOLUTION AND INFORMATION PROCESSING, 2005, 3 (01) : 19 - 42
  • [30] Beat-to-beat blood pressure variability in patients with obstructive sleep apnea
    Pal, Amrita
    Martinez, Fernando
    Aguila, Andrea P.
    Akey, Margaret A.
    Chatterjee, Roopsha
    Conserman, Merry Grace E.
    Aysola, Ravi S.
    Henderson, Luke A.
    Macey, Paul M.
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2021, 17 (03): : 381 - 392