Wearable Piezoelectric-Based System for Continuous Beat-to-Beat Blood Pressure Measurement

被引:54
|
作者
Wang, Ting-Wei [1 ]
Lin, Shien-Fong [1 ,2 ,3 ]
机构
[1] Natl Chiao Tung Univ, Dept Elect & Comp Engn, Coll Elect & Comp Engn, Hsinchu 30010, Taiwan
[2] Natl Chiao Tung Univ, Inst Biomed Engn, Coll Elect & Comp Engn, Hsinchu 30010, Taiwan
[3] Indiana Univ Sch Med, Krannert Inst Cardiol, Indianapolis, IN 46202 USA
关键词
continuous blood pressure; piezoelectric sensor; wearable device; PULSE TRANSIT-TIME;
D O I
10.3390/s20030851
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Non-invasive continuous blood pressure measurement is an emerging issue that potentially can be applied to cardiovascular disease monitoring and prediction. Recently, many groups have proposed the pulse transition time (PTT) method to estimate blood pressure for long-term monitoring. However, the PTT-based methods for blood pressure estimation are limited by non-specific estimation models and require multiple calibrations. This study aims to develop a low-cost wearable piezoelectric-based system for continuous beat-to-beat blood pressure measurement. The pressure change in the radial artery was extracted by systolic and diastolic feature points in pressure pulse wave (PPW) and the pressure sensitivity of the sensor. The proposed system showed a reliable accuracy of systolic blood pressure (SBP) (mean absolute error (MAE) +/- standard deviation (SD) 1.52 +/- 0.30 mmHg) and diastolic blood pressure (DBP, MAE +/- SD 1.83 +/- 0.50), and its performance agreed with standard criteria of MAE within 5 mmHg and SD within +/- 8 mmHg. In conclusion, this study successfully developed a low-cost, high-accuracy piezoelectric-based system for continuous beat-to-beat SBP and DBP measurement without multiple calibrations and complex regression analysis. The system is potentially suitable for continuous, long-term blood pressure-monitoring applications.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] NONINVASIVE VS INVASIVE BEAT-TO-BEAT MONITORING OF BLOOD-PRESSURE
    GABRIEL, A
    LINDBLAD, LE
    ANGLERYD, C
    CLINICAL PHYSIOLOGY, 1992, 12 (02): : 229 - 235
  • [32] Soft Iontronic Capacitive Sensor for Beat-to-Beat Blood Pressure Measurements
    Rwei, Patrick
    Qian, Chengyang
    Abiri, Arash
    Zhou, Yongxiao
    Chou, En-Fan
    Tang, William C.
    Khine, Michelle
    ADVANCED MATERIALS INTERFACES, 2022, 9 (18):
  • [33] Cuffless Beat-to-Beat Blood Pressure Estimation from Photoplethysmogram Signals
    Wuerich, Carolin
    Wiede, Christian
    Schiele, Gregor
    2023 IEEE 36TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, CBMS, 2023, : 305 - 310
  • [34] Beat-to-beat blood pressure and heart rate responses to the Valsalva maneuver
    David S. Goldstein
    William P. Cheshire
    Clinical Autonomic Research, 2017, 27 : 361 - 367
  • [35] Finger beat-to-beat blood pressure responses to successive hand elevations
    Raamat, R.
    Jagomagi, K.
    Talts, J.
    Mager, I.
    MEDICAL ENGINEERING & PHYSICS, 2009, 31 (05) : 522 - 527
  • [36] Beat-to-beat blood pressure biofeedback as a supplementary treatment for arterial hypertension
    Piesbergen, Christoph
    Kircher, Katharina
    Weber, Reinhard
    VERHALTENSTHERAPIE, 2008, 18 (02) : 83 - 90
  • [37] BEAT-TO-BEAT BLOOD-PRESSURE RESPONSE IN ASYMPTOMATIC IDDM SUBJECTS
    GOLDSTEIN, IB
    NALIBOFF, BD
    SHAPIRO, D
    FRANK, HJL
    DIABETES CARE, 1988, 11 (10) : 774 - 779
  • [38] Beat-to-beat blood pressure and heart rate responses to the Valsalva maneuver
    Goldstein, David S.
    Cheshire, William P., Jr.
    CLINICAL AUTONOMIC RESEARCH, 2017, 27 (06) : 361 - 367
  • [39] Beat-to-Beat Blood Pressure Variation and Cardiovascular Organ Injuries in Hypertension
    Ishimitsu, Toshihiko
    CIRCULATION JOURNAL, 2014, 78 (09) : 2162 - 2163
  • [40] Reduced resting beat-to-beat blood pressure variability in multiple sclerosis
    Trotter, Claire
    Young, Ben
    Huang, Mu
    Allen, Dustin
    Fade, Paul
    Davis, Scott
    FASEB JOURNAL, 2021, 35