Soft Wearable Pressure Sensors for Beat-to-Beat Blood Pressure Monitoring

被引:173
|
作者
Kim, Joshua [1 ]
Chou, En-Fan [2 ]
Le, Jamie [2 ]
Wong, Sabrina [2 ]
Chu, Michael [2 ]
Khine, Michelle [1 ,2 ]
机构
[1] Univ Calif Irvine, Dept Mat Sci & Engn, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
关键词
blood pressure; flexible electronics; health sensors; pressure sensors; wearable electronics; ARTERIAL PULSE; VARIABILITY; TONOMETRY; WAVE;
D O I
10.1002/adhm.201900109
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wrinkled gold thin films on elastomeric substrates are used as robust parallel plate electrodes for soft capacitive pressure sensors. The wrinkled structures create a robust integration with the polymer, allowing repeated normal force to deform the thin film without failure. By incorporating microridged structures that support the counter electrodes to create air cavities within the elastomeric dielectric layer, pressure sensitivity is further increased to 0.148 kPa(-1) over a wide dynamic range of up to 10 kPa. The wide dynamic range and pressure sensitivity of the pressure sensor allow for consistent measurements of the pressure exerted by the radial artery located on the wrist. The soft capacitive pressure sensor displays comparable results when tested against an FDA approved device (Clearsight, Edwards Lifesciences, Irvine, CA) measuring beat-to-beat blood pressure. These soft pressure sensors using wrinkled thin films, therefore, illustrate considerable potential to continuously monitor beat-to-beat blood pressure.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Soft Iontronic Capacitive Sensor for Beat-to-Beat Blood Pressure Measurements
    Rwei, Patrick
    Qian, Chengyang
    Abiri, Arash
    Zhou, Yongxiao
    Chou, En-Fan
    Tang, William C.
    Khine, Michelle
    ADVANCED MATERIALS INTERFACES, 2022, 9 (18):
  • [2] ADOPTION OF CONTINUOUS BEAT-TO-BEAT NOCTURNAL BLOOD PRESSURE MEASUREMENT IN AMBULATORY BLOOD PRESSURE MONITORING
    Estrada, Sebastian
    Kwon, Younghoon
    Baruch, Martin
    Harrison, Elizabeth
    Williams, Ronald
    Cho, Yeilim
    Gerdt, David
    Bonner, Heather
    Mazimba, Sula
    Berry, Richard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1893 - 1893
  • [3] NONINVASIVE VS INVASIVE BEAT-TO-BEAT MONITORING OF BLOOD-PRESSURE
    GABRIEL, A
    LINDBLAD, LE
    ANGLERYD, C
    CLINICAL PHYSIOLOGY, 1992, 12 (02): : 229 - 235
  • [4] Wearable Piezoelectric-Based System for Continuous Beat-to-Beat Blood Pressure Measurement
    Wang, Ting-Wei
    Lin, Shien-Fong
    SENSORS, 2020, 20 (03)
  • [5] Non-invasive beat-to-beat blood pressure monitoring: new developments
    Parati, G
    Ongaro, G
    Bilo, G
    Glavina, F
    Castiglioni, P
    Di Rienzo, M
    Mancia, G
    BLOOD PRESSURE MONITORING, 2003, 8 (01) : 31 - 36
  • [6] Ambulatory and beat-to-beat blood pressure variability: Are they related?
    Sloan, RP
    Shapiro, PA
    Bagiella, E
    McKinley, PS
    Myers, MM
    Brondolo, EN
    Eichler, B
    PSYCHOSOMATIC MEDICINE, 2001, 63 (01): : 172 - 172
  • [7] Baroreflex failure and beat-to-beat blood pressure variation
    Kishi, Takuya
    HYPERTENSION RESEARCH, 2018, 41 (08) : 547 - 552
  • [8] Baroreflex failure and beat-to-beat blood pressure variation
    Takuya Kishi
    Hypertension Research, 2018, 41 : 547 - 552
  • [9] Beat-to-beat oscillations in pulse pressure
    Virtanen, R
    Jula, A
    Kuusela, T
    Airaksinen, J
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2004, 24 (05) : 304 - 309
  • [10] Beat-to-Beat Blood Pressure Variability and Cognition in the MIDUS Study
    Sweigert, Joshua
    McKinley, Paula
    Lachman, Margie
    Gruenewald, Tara
    Seeman, Teresa
    Love, Gayle
    Weinstein, Maxine
    McIntyre, Kathleen
    Duong, Jimmy
    Sloan, Richard P.
    PSYCHOSOMATIC MEDICINE, 2017, 79 (04): : A154 - A155