Soft Wearable Pressure Sensors for Beat-to-Beat Blood Pressure Monitoring

被引:173
|
作者
Kim, Joshua [1 ]
Chou, En-Fan [2 ]
Le, Jamie [2 ]
Wong, Sabrina [2 ]
Chu, Michael [2 ]
Khine, Michelle [1 ,2 ]
机构
[1] Univ Calif Irvine, Dept Mat Sci & Engn, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
关键词
blood pressure; flexible electronics; health sensors; pressure sensors; wearable electronics; ARTERIAL PULSE; VARIABILITY; TONOMETRY; WAVE;
D O I
10.1002/adhm.201900109
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wrinkled gold thin films on elastomeric substrates are used as robust parallel plate electrodes for soft capacitive pressure sensors. The wrinkled structures create a robust integration with the polymer, allowing repeated normal force to deform the thin film without failure. By incorporating microridged structures that support the counter electrodes to create air cavities within the elastomeric dielectric layer, pressure sensitivity is further increased to 0.148 kPa(-1) over a wide dynamic range of up to 10 kPa. The wide dynamic range and pressure sensitivity of the pressure sensor allow for consistent measurements of the pressure exerted by the radial artery located on the wrist. The soft capacitive pressure sensor displays comparable results when tested against an FDA approved device (Clearsight, Edwards Lifesciences, Irvine, CA) measuring beat-to-beat blood pressure. These soft pressure sensors using wrinkled thin films, therefore, illustrate considerable potential to continuously monitor beat-to-beat blood pressure.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Beat-to-beat blood pressure and heart rate responses to the Valsalva maneuver
    David S. Goldstein
    William P. Cheshire
    Clinical Autonomic Research, 2017, 27 : 361 - 367
  • [22] Finger beat-to-beat blood pressure responses to successive hand elevations
    Raamat, R.
    Jagomagi, K.
    Talts, J.
    Mager, I.
    MEDICAL ENGINEERING & PHYSICS, 2009, 31 (05) : 522 - 527
  • [23] Beat-to-beat blood pressure biofeedback as a supplementary treatment for arterial hypertension
    Piesbergen, Christoph
    Kircher, Katharina
    Weber, Reinhard
    VERHALTENSTHERAPIE, 2008, 18 (02) : 83 - 90
  • [24] BEAT-TO-BEAT BLOOD-PRESSURE RESPONSE IN ASYMPTOMATIC IDDM SUBJECTS
    GOLDSTEIN, IB
    NALIBOFF, BD
    SHAPIRO, D
    FRANK, HJL
    DIABETES CARE, 1988, 11 (10) : 774 - 779
  • [25] Beat-to-beat blood pressure and heart rate responses to the Valsalva maneuver
    Goldstein, David S.
    Cheshire, William P., Jr.
    CLINICAL AUTONOMIC RESEARCH, 2017, 27 (06) : 361 - 367
  • [26] Beat-to-Beat Blood Pressure Variation and Cardiovascular Organ Injuries in Hypertension
    Ishimitsu, Toshihiko
    CIRCULATION JOURNAL, 2014, 78 (09) : 2162 - 2163
  • [27] Effect of peripheral vasoconstriction on the beat-to-beat measurement of finger blood pressure
    Raamat, R
    Talts, J
    Jagomägi, K
    Kingisepp, PH
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2223 - 2226
  • [28] Reduced resting beat-to-beat blood pressure variability in multiple sclerosis
    Trotter, Claire
    Young, Ben
    Huang, Mu
    Allen, Dustin
    Fade, Paul
    Davis, Scott
    FASEB JOURNAL, 2021, 35
  • [29] Beat-to-beat ambulatory blood pressure variability is different from intermittent ambulatory blood pressure variability
    Sloan, RP
    Berg, J
    Bagiella, E
    Chernikhova, D
    Myers, MM
    PSYCHOSOMATIC MEDICINE, 1998, 60 (01): : 109 - 109
  • [30] Elucidation of obstructive sleep apnoea related blood pressure surge using a novel continuous beat-to-beat blood pressure monitoring system
    Kwon, Younghoon
    Baruch, Martin
    Stafford, Patrick L.
    Bonner, Heather
    Cho, Yeilim
    Mazimba, Sula
    Logan, Jeongok G.
    Shimbo, Daichi
    Park, Sung-Ha
    Lin, Gen-Min
    Azarbarzin, Ali
    Calhoun, David A.
    Berry, Richard
    Carey, Robert M.
    JOURNAL OF HYPERTENSION, 2022, 40 (03) : 520 - 527