Diffusion Tensor Imaging of the Normal Pediatric Spinal Cord Using an Inner Field of View Echo-Planar Imaging Sequence

被引:40
|
作者
Barakat, N. [2 ]
Mohamed, F. B. [1 ]
Hunter, L. N.
Shah, P.
Faro, S. H.
Samdani, A. F. [3 ]
Finsterbusch, J. [4 ]
Betz, R. [3 ]
Gaughan, J. [5 ]
Mulcahey, M. J. [3 ]
机构
[1] Temple Univ, Sch Med, Dept Radiol, Philadelphia, PA 19140 USA
[2] Temple Univ, Dept Bioengn, Philadelphia, PA 19140 USA
[3] Shriners Hosp Children, Philadelphia, PA USA
[4] Univ Med Ctr Hamburg Eppendorf, Dept Syst Neurosci, Hamburg, Germany
[5] Temple Univ, Sch Med, Biostat Consulting Ctr, Philadelphia, PA 19140 USA
关键词
IN-VIVO; NEUROLOGICAL CLASSIFICATION; INTERNATIONAL STANDARDS; HUMAN BRAIN; CHILDREN; CHILDHOOD; INJURY; ANISOTROPY; MOTION;
D O I
10.3174/ajnr.A2924
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: DTI in the brain has been well established, but its application in the spinal cord, especially in pediatrics, poses several challenges. The small cord size has inherent low SNR of the diffusion signal intensity, respiratory and cardiac movements induce artifacts, and EPI sequences used for obtaining diffusion indices cause eddy-current distortions. The purpose of this study was to 1) evaluate the accuracy of cervical spinal cord DTI in children using a newly developed iFOV sequence with spatially selective 2D-RF excitations, and 2) examine reproducibility of the DTI measures. MATERIALS AND METHODS: Twenty-five typically developing subjects were imaged twice using a 3T scanner. Axial DTI images of the cervical spinal cord were acquired with this sequence. After motion correction, DTI indices were calculated using regions of interest manually drawn at every axial section location along the cervical spinal cord for both acquisitions. Various DTI indices were calculated: FA, AD, RD, MD, RA, and VR. Geometric diffusion measures were also calculated: Cp, Cl, and Cs. RESULTS: The following average values for each index were obtained: FA = 0.50 +/- 0.11; AD = 0.97 +/- 0.20 x 10(-3)mm(2)/s; RD = 0.41 +/- 0.13 x 10(-3)mm(2)/s; MD = 0.59 +/- 0.15 x 10(-3)mm(2)/s; RA = 0.35 +/- 0.08; VR = 0.03 +/- 0.00; Cp = 0.13 +/- 0.07; CI = 0.29 +/- 0.09; and Cs = 0.58 +/- 0.11. The reproducibility tests showed moderate to strong ICC in all subjects for all DTI parameters (ICC>0.72). CONCLUSIONS: This study showed that accurate and reproducible DTI parameters can be estimated in the pediatric cervical spinal cord using an iFOV EPI sequence.
引用
收藏
页码:1127 / 1133
页数:7
相关论文
共 50 条
  • [41] An optimized magnetic tissue tagging sequence for echo-planar imaging
    Al-Omari, F
    Chwialkowski, M
    Clarke, G
    Peshock, R
    11TH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, PROCEEDINGS, 1998, : 144 - 150
  • [42] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Chen-Jiang Wu
    Qing Wang
    Jing Zhang
    Xiao-Ning Wang
    Xi-Sheng Liu
    Yu-Dong Zhang
    Hai-Bin Shi
    Abdominal Radiology, 2016, 41 : 100 - 108
  • [43] High resolution diffusion weighted magnetic resonance imaging of the pancreas using reduced field of view single-shot echo-planar imaging at 3 T
    Ma, Chao
    Li, Yan-jun
    Pan, Chun-shu
    Wang, He
    Wang, Jian
    Chen, Shi-yue
    Lu, Jian-ping
    MAGNETIC RESONANCE IMAGING, 2014, 32 (02) : 125 - 131
  • [44] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Wu, Chen-Jiang
    Wang, Qing
    Zhang, Jing
    Wang, Xiao-Ning
    Liu, Xi-Sheng
    Zhang, Yu-Dong
    Shi, Hai-Bin
    ABDOMINAL RADIOLOGY, 2016, 41 (01) : 100 - 108
  • [45] Detection of Middle Ear Cholesteatoma by Diffusion-Weighted MR Imaging: Multishot Echo-Planar Imaging Compared with Single-Shot Echo-Planar Imaging
    Yamashita, K.
    Yoshiura, T.
    Hiwatashi, A.
    Kamano, H.
    Dashjamts, T.
    Shibata, S.
    Tamae, A.
    Honda, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (10) : 1915 - 1918
  • [46] NORMAL HEART - EVALUATION WITH ECHO-PLANAR MR-IMAGING
    DAVIS, CP
    MCKINNON, GC
    DEBATIN, JF
    WETTER, D
    EICHENBERGER, AC
    DUEWELL, S
    VONSCHULTHESS, GK
    RADIOLOGY, 1994, 191 (03) : 691 - 696
  • [47] Normal myocardial perfusion assessed with multishot echo-planar imaging
    Schwitter, J
    Debatin, JF
    vonSchulthess, GK
    McKinnon, GC
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (01) : 140 - 147
  • [48] High-resolution diffusion imaging using phase-corrected segmented echo-planar imaging
    Brockstedt, S
    Moore, JR
    Thomsen, C
    Holtås, S
    Ståhlberg, F
    MAGNETIC RESONANCE IMAGING, 2000, 18 (06) : 649 - 657
  • [49] Diffusion tensor imaging in the cervical spinal cord
    Song, Ting
    Chen, Wen-Jun
    Yang, Bo
    Zhao, Hong-Pu
    Huang, Jian-Wei
    Cai, Ming-Jin
    Dong, Tian-Fa
    Li, Tang-Sheng
    EUROPEAN SPINE JOURNAL, 2011, 20 (03) : 422 - 428
  • [50] Diffusion tensor imaging in the cervical spinal cord
    Ting Song
    Wen-Jun Chen
    Bo Yang
    Hong-Pu Zhao
    Jian-Wei Huang
    Ming-Jin Cai
    Tian-Fa Dong
    Tang-Sheng Li
    European Spine Journal, 2011, 20 : 422 - 428