Diffusion Tensor Imaging of the Normal Pediatric Spinal Cord Using an Inner Field of View Echo-Planar Imaging Sequence

被引:40
|
作者
Barakat, N. [2 ]
Mohamed, F. B. [1 ]
Hunter, L. N.
Shah, P.
Faro, S. H.
Samdani, A. F. [3 ]
Finsterbusch, J. [4 ]
Betz, R. [3 ]
Gaughan, J. [5 ]
Mulcahey, M. J. [3 ]
机构
[1] Temple Univ, Sch Med, Dept Radiol, Philadelphia, PA 19140 USA
[2] Temple Univ, Dept Bioengn, Philadelphia, PA 19140 USA
[3] Shriners Hosp Children, Philadelphia, PA USA
[4] Univ Med Ctr Hamburg Eppendorf, Dept Syst Neurosci, Hamburg, Germany
[5] Temple Univ, Sch Med, Biostat Consulting Ctr, Philadelphia, PA 19140 USA
关键词
IN-VIVO; NEUROLOGICAL CLASSIFICATION; INTERNATIONAL STANDARDS; HUMAN BRAIN; CHILDREN; CHILDHOOD; INJURY; ANISOTROPY; MOTION;
D O I
10.3174/ajnr.A2924
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: DTI in the brain has been well established, but its application in the spinal cord, especially in pediatrics, poses several challenges. The small cord size has inherent low SNR of the diffusion signal intensity, respiratory and cardiac movements induce artifacts, and EPI sequences used for obtaining diffusion indices cause eddy-current distortions. The purpose of this study was to 1) evaluate the accuracy of cervical spinal cord DTI in children using a newly developed iFOV sequence with spatially selective 2D-RF excitations, and 2) examine reproducibility of the DTI measures. MATERIALS AND METHODS: Twenty-five typically developing subjects were imaged twice using a 3T scanner. Axial DTI images of the cervical spinal cord were acquired with this sequence. After motion correction, DTI indices were calculated using regions of interest manually drawn at every axial section location along the cervical spinal cord for both acquisitions. Various DTI indices were calculated: FA, AD, RD, MD, RA, and VR. Geometric diffusion measures were also calculated: Cp, Cl, and Cs. RESULTS: The following average values for each index were obtained: FA = 0.50 +/- 0.11; AD = 0.97 +/- 0.20 x 10(-3)mm(2)/s; RD = 0.41 +/- 0.13 x 10(-3)mm(2)/s; MD = 0.59 +/- 0.15 x 10(-3)mm(2)/s; RA = 0.35 +/- 0.08; VR = 0.03 +/- 0.00; Cp = 0.13 +/- 0.07; CI = 0.29 +/- 0.09; and Cs = 0.58 +/- 0.11. The reproducibility tests showed moderate to strong ICC in all subjects for all DTI parameters (ICC>0.72). CONCLUSIONS: This study showed that accurate and reproducible DTI parameters can be estimated in the pediatric cervical spinal cord using an iFOV EPI sequence.
引用
收藏
页码:1127 / 1133
页数:7
相关论文
共 50 条
  • [21] Segmentation of Spinal Cord in the Pediatric Spinal Diffusion Tensor MR Imaging
    Alizadeh, Mahdi
    Mohamed, Feroze B.
    Faro, Scott H.
    Shah, Pallav
    Middleton, Devon M.
    Conklin, Chris J.
    Mulcahey, M. J.
    2015 41ST ANNUAL NORTHEAST BIOMEDICAL ENGINEERING CONFERENCE (NEBEC), 2015,
  • [22] Pediatric diffusion-weighted echo-planar imaging: Early clinical experience
    Ptak, T
    Kothare, SV
    Dooling, EC
    Gonzalez, RG
    Schaefer, PW
    RADIOLOGY, 1996, 201 : 966 - 966
  • [23] Ultrahigh Resolution Reduced Field-Of-View Diffusion Tensor Imaging in the Spinal Cord
    Gaggl, W.
    Reuss, J.
    Field, A.
    MEDICAL PHYSICS, 2014, 41 (06) : 141 - 141
  • [24] DIFFUSION TENSOR IMAGING IN THE PEDIATRIC SPINAL CORD INJURY POPULATION
    Krisa, Laura
    Saksena, Sona
    Middleton, Devon
    Sinko, Rebecca
    Conklin, Christopher
    Faro, Scott
    Gaughan, John
    Mulcahey, M. J.
    Mohamed, Feroze
    JOURNAL OF NEUROTRAUMA, 2016, 33 (13) : A48 - A48
  • [25] Echo Planar Diffusion Tensor Imaging of the Mouse Spinal Cord at Thoracic and Lumbar Levels: A Feasibility Study
    Callot, Virginie
    Duhamel, Guillaume
    Le Fur, Yann
    Decherchi, Patrick
    Marqueste, Tanguy
    Kober, Frank
    Cozzone, Patrick J.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (04) : 1125 - 1134
  • [26] Construction of Brain Structural Connectome Using PROPELLER Echo-Planar Diffusion Tensor Imaging with Probabilistic Tractography: Comparison with Conventional Imaging
    Ya-Ling Lin
    Tsyh-Jyi Hsieh
    Ming-Chung Chou
    Journal of Medical and Biological Engineering, 2018, 38 : 625 - 633
  • [27] Construction of Brain Structural Connectome Using PROPELLER Echo-Planar Diffusion Tensor Imaging with Probabilistic Tractography: Comparison with Conventional Imaging
    Lin, Ya-Ling
    Hsieh, Tsyh-Jyi
    Chou, Ming-Chung
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2018, 38 (04) : 625 - 633
  • [28] Diffusion tensor imaging of the spinal cord
    Maier, SE
    Mamata, H
    WHITE MATTER IN COGNITIVE NEUROSCIENCE: ADVANCES IN DIFFUSION TENSOR IMAGING AND ITS APPLICATIONS, 2005, 1064 : 50 - +
  • [29] Diffusion Tensor Imaging of the Spinal Cord
    Cheng, Sho-Jen
    Tsai, Ping-Huei
    Lee, Yun-Ting
    Li, Yi-Tien
    Chung, Hsiao-Wen
    Chen, Cheng-Yu
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2021, 29 (02) : 195 - 204
  • [30] Diffusion tensor imaging of the spinal cord with a single-shot fast spin-echo sequence
    Hackney, DB
    Kharbanda, H
    Schwartz, ED
    Alsop, DC
    RADIOLOGY, 2000, 217 : 390 - 390