Diffusion Tensor Imaging of the Normal Pediatric Spinal Cord Using an Inner Field of View Echo-Planar Imaging Sequence

被引:40
|
作者
Barakat, N. [2 ]
Mohamed, F. B. [1 ]
Hunter, L. N.
Shah, P.
Faro, S. H.
Samdani, A. F. [3 ]
Finsterbusch, J. [4 ]
Betz, R. [3 ]
Gaughan, J. [5 ]
Mulcahey, M. J. [3 ]
机构
[1] Temple Univ, Sch Med, Dept Radiol, Philadelphia, PA 19140 USA
[2] Temple Univ, Dept Bioengn, Philadelphia, PA 19140 USA
[3] Shriners Hosp Children, Philadelphia, PA USA
[4] Univ Med Ctr Hamburg Eppendorf, Dept Syst Neurosci, Hamburg, Germany
[5] Temple Univ, Sch Med, Biostat Consulting Ctr, Philadelphia, PA 19140 USA
关键词
IN-VIVO; NEUROLOGICAL CLASSIFICATION; INTERNATIONAL STANDARDS; HUMAN BRAIN; CHILDREN; CHILDHOOD; INJURY; ANISOTROPY; MOTION;
D O I
10.3174/ajnr.A2924
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: DTI in the brain has been well established, but its application in the spinal cord, especially in pediatrics, poses several challenges. The small cord size has inherent low SNR of the diffusion signal intensity, respiratory and cardiac movements induce artifacts, and EPI sequences used for obtaining diffusion indices cause eddy-current distortions. The purpose of this study was to 1) evaluate the accuracy of cervical spinal cord DTI in children using a newly developed iFOV sequence with spatially selective 2D-RF excitations, and 2) examine reproducibility of the DTI measures. MATERIALS AND METHODS: Twenty-five typically developing subjects were imaged twice using a 3T scanner. Axial DTI images of the cervical spinal cord were acquired with this sequence. After motion correction, DTI indices were calculated using regions of interest manually drawn at every axial section location along the cervical spinal cord for both acquisitions. Various DTI indices were calculated: FA, AD, RD, MD, RA, and VR. Geometric diffusion measures were also calculated: Cp, Cl, and Cs. RESULTS: The following average values for each index were obtained: FA = 0.50 +/- 0.11; AD = 0.97 +/- 0.20 x 10(-3)mm(2)/s; RD = 0.41 +/- 0.13 x 10(-3)mm(2)/s; MD = 0.59 +/- 0.15 x 10(-3)mm(2)/s; RA = 0.35 +/- 0.08; VR = 0.03 +/- 0.00; Cp = 0.13 +/- 0.07; CI = 0.29 +/- 0.09; and Cs = 0.58 +/- 0.11. The reproducibility tests showed moderate to strong ICC in all subjects for all DTI parameters (ICC>0.72). CONCLUSIONS: This study showed that accurate and reproducible DTI parameters can be estimated in the pediatric cervical spinal cord using an iFOV EPI sequence.
引用
收藏
页码:1127 / 1133
页数:7
相关论文
共 50 条
  • [31] Cholesteatoma imaging using modified echo-planar diffusion-weighted magnetic resonance imaging
    Flook, E.
    Izzat, S.
    Ismail, A.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2011, 125 (01): : 10 - 12
  • [32] Analysis and correction of off-resonance artifacts in echo-planar cardiac diffusion tensor imaging
    van Gorkum, Robbert J. H.
    von Deuster, Constantin
    Guenthner, Christian
    Stoeck, Christian T.
    Kozerke, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (05) : 2561 - 2576
  • [33] How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging
    Andersson, JLR
    Skare, S
    Ashburner, J
    NEUROIMAGE, 2003, 20 (02) : 870 - 888
  • [34] Modified Reduced Field-of-View Diffusion-Weighted Magnetic Resonance Imaging of the Prostate: Comparison With Reduced Field-of-View Imaging and Single Shot Echo-Planar Imaging
    Lee, Eun Ji
    Hwang, Jiyoung
    Chang, Yun-Woo
    Hong, Seong Sook
    Oh, Eunsun
    Nam, Bo Da
    Sung, Jae Kon
    Thomas, Benkert
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (03) : 367 - 373
  • [35] In vivo measurement of the apparent diffusion coefficient in normal and malignant prostatic tissues using echo-planar imaging
    Issa, B
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (02) : 196 - 200
  • [36] Spinal cord functional MRI at 3 T: Gradient echo echo-planar imaging versus turbo spin echo
    Bouwman, C. J. C.
    Wilmink, J. T.
    Mess, W. H.
    Backes, W. H.
    NEUROIMAGE, 2008, 43 (02) : 288 - 296
  • [37] Motion Correction Algorithms for Pediatric Spinal Cord Diffusion Tensor Imaging
    Middleton, Devon M.
    Mohamed, Feroze B.
    Barakat, Nadia
    Hunter, Louis N.
    Finsterbusch, Jurgen
    Faro, Scott H.
    Shah, Pallav
    Samdani, Amer
    Mulcahey, M. J.
    2012 38TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC), 2012, : 79 - +
  • [38] DIFFUSION TENSOR IMAGING AS A BIOMARKER TO IDENTIFY SPINAL CORD INTEGRITY IN PEDIATRIC SPINAL CORD INJURY
    Krisa, Laura
    Saksena, Sona
    Faro, Scott
    Gaughan, John
    Middleton, Devon M.
    Mulcahey, Mj
    Mohamed, Feroze B.
    JOURNAL OF NEUROTRAUMA, 2018, 35 (16) : A175 - A175
  • [39] VISUALIZATION OF TURBULENT MOTION USING ECHO-PLANAR IMAGING WITH A SPATIAL TAGGING SEQUENCE
    KOSE, K
    JOURNAL OF MAGNETIC RESONANCE, 1992, 98 (03): : 599 - 603
  • [40] SELECTIVE MULTISHOT ECHO-PLANAR IR IMAGING IN PEDIATRIC NEURORADIOLOGY
    POSKITT, KJ
    SARGENT, MA
    RADIOLOGY, 1995, 197 : 269 - 269