Comparison of HASTE with multiple signal averaging versus conventional turbo spin echo sequence: a new option for T2-weighted MRI of the female pelvis

被引:12
|
作者
Tsuboyama, Takahiro [1 ]
Takei, Oki [1 ]
Okada, Atsuhiko [1 ]
Honda, Toru [1 ]
Kuriyama, Keiko [1 ]
机构
[1] Natl Hosp Org Osaka Natl Hosp, Dept Radiol, Chuo Ku, 2-1-14 Hoenzaka, Osaka 5400006, Japan
关键词
Magnetic resonance imaging; Spin echo imaging; Pelvis; Female; IMAGE QUALITY; INCREASED SPEED; ACQUISITION; BLADE; 3D;
D O I
10.1007/s00330-020-06686-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives This study was conducted in order to evaluate the feasibility of a newly developed half-Fourier acquisition single-shot turbo spin echo (HASTE) sequence for T2-weighted MRI of the female pelvis, in which scanning and post-processing filtering techniques were optimized to minimize blurring and the resultant reduction in signal-to-noise ratio (SNR) was compensated by signal averaging of multiple excitations (multi-NEX), and to compare its image quality with that of a conventional turbo spin echo (TSE) sequence. Methods Fifty females with gynecological disease were prospectively enrolled. They underwent pelvic MRI including sagittal T2-weighted imaging obtained with multi-NEX HASTE (mHASTE) and TSE with acquisition times of 1 m 9 s and 3 m 26 s, respectively. At the prospective reading, mHASTE was reviewed first, and any changes in the image interpretation detected during the subsequent TSE reading were recorded. The SNR and tissue contrast were quantitatively measured. Two radiologists independently assessed tissue conspicuity and overall image quality considering noise, artifacts, and blurring, and visual grading characteristics (VGC) analysis was performed to compare the two sequences. Results Adding TSE to mHASTE did not change image interpretations in any case. mHASTE produced an equivalent SNR and significantly higher contrast between the myometrium and junctional zone (p < 0.05) compared with TSE. The area under the VGC curve (AUC(VGC)) showed that the conspicuity of the uterus, ovaries, and lesions and the overall image quality were significantly higher on mHASTE than on TSE for both readers (AUC(VGC), 0.740-0.880; p < 0.01). Conclusion mHASTE is a feasible option for T2-weighted MRI of the female pelvis, as it allows faster and higher-quality image acquisition than conventional TSE.
引用
收藏
页码:3245 / 3253
页数:9
相关论文
共 50 条
  • [1] Comparison of HASTE with multiple signal averaging versus conventional turbo spin echo sequence: a new option for T2-weighted MRI of the female pelvis
    Takahiro Tsuboyama
    Oki Takei
    Atsuhiko Okada
    Toru Honda
    Keiko Kuriyama
    European Radiology, 2020, 30 : 3245 - 3253
  • [2] Comparison of multishot turbo spin echo and HASTE sequences for T2-weighted MRI of liver lesions
    Yu, JS
    Kim, KW
    Kim, YH
    Jeong, EK
    Chien, D
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (05): : 1079 - 1084
  • [3] Comparison of ultrafast half-Fourier single-shot turbo spin-echo sequence with turbo spin-echo sequences for T2-weighted imaging of the female pelvis
    Yamashita, Y
    Tang, Y
    Abe, Y
    Mitsuzaki, K
    Takahashi, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (06): : 1207 - 1212
  • [4] Comparison of HASTE and segmented-HASTE sequences with a T2-weighted fast spin-echo sequence in the screening evaluation of the brain
    Sugahara, T
    Korogi, Y
    Hirai, T
    Hamatake, S
    Ikushima, I
    Shigematu, Y
    Takahashi, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (05) : 1401 - 1410
  • [5] Semicircular canal dehiscence: comparison of T2-weighted turbo spin-echo MRI and CT
    G. A. Krombach
    T. Schmitz-Rode
    P. Haage
    E. DiMartino
    A. Prescher
    S. Kinzel
    R. W. Günther
    Neuroradiology, 2004, 46 : 326 - 331
  • [6] Semicircular canal dehiscence:: comparison of T2-weighted turbo spin-echo MRI and CT
    Krombach, GA
    Schmitz-Rode, T
    Haage, P
    DiMartino, E
    Prescher, A
    Kinzel, S
    Günther, RW
    NEURORADIOLOGY, 2004, 46 (04) : 326 - 331
  • [7] T2-weighted breath-hold MRI of the liver at 1.0 T: Comparison of turbo spin-echo and HASTE sequences with and without fat suppression
    Kim, TK
    Lee, HJ
    Jang, HJ
    Kim, AY
    Han, JK
    Choi, BI
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (06): : 1213 - 1218
  • [8] Hepatic T2-weighted MRI: A prospective comparison of sequences, including breath-hold, half-Fourier turbo spin echo (HASTE)
    Coates, GG
    Borrello, JA
    McFarland, EG
    Mirowitz, SA
    Brown, JJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03): : 642 - 649
  • [9] HASTE versus fast spin-echo: The competition for T2-weighted imaging is going on
    Helmberger, TK
    Gregor, M
    Schroeder, J
    Holzknecht, NG
    Heuck, AF
    Reiser, MF
    RADIOLOGY, 1997, 205 : 1198 - 1198
  • [10] Comparison of Sagittal T2-Weighted BLADE and Fast Spin-Echo MRI of the Female Pelvis for Motion Artifact and Lesion Detection
    Lane, Barton F.
    Vandermeer, Fauzia Q.
    Oz, Rasim C.
    Irwin, Eric W.
    McMillan, Alan B.
    Wong-You-Cheong, Jade J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (02) : W307 - W313