EVALUATING CLINICAL STOPPING POWER ESTIMATION FROM A RADIOTHERAPY DUAL ENERGY CT SCANNER

被引:3
|
作者
Almeida, Isabel P. [1 ]
Landry, Guillaume [2 ]
Dedes, George [2 ]
Patel, Rakesh [3 ]
Pankuch, Mark [4 ]
Coutrakon, George [5 ]
Schulte, Reinhard [6 ]
Verhaegen, Frank [1 ]
Parodi, Katia [2 ]
Roeske, John C. [3 ]
机构
[1] Maastricht Univ, Med Ctr, GROW Sch Oncol & Dev Biol, Dept Radiat Oncol MAASTRO, Maastricht, Netherlands
[2] Ludwig Maximilians Univ Munchen, Fac Phys, Dept Med Phys, Garching, Germany
[3] Loyola Univ Chicago, Stritch Sch Med, Dept Radiat Oncol, Div Med Phys, Maywood, IL USA
[4] Northwestern Med Chicago Proton Ctr, Warrenville, IL USA
[5] Northern Illinois Univ, Dept Phys, De Kalb, IL USA
[6] Loma Linda Univ, Div Biomed Sci, Loma Linda, CA 92350 USA
来源
ACTA PHYSICA POLONICA B | 2017年 / 48卷 / 10期
关键词
BEAM;
D O I
10.5506/APhysPolB.48.1619
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The use of dual energy computed tomography (DECT) is increasingly considered in particle therapy (PT) to reduce the range of uncertainties attributed to the conversion of X-ray linear attenuation coefficients into relative stopping power (RSP). DECT scanners equipped with clinically available image conversion software can now be found in PT centers. In this work, RSP calculated on the basis of clinical DECT scanner software (syngo. via) was compared to a validated published procedure (Hudobivnik) for calibration and pediatric head phantoms. Based on material inserts, the average difference between RSP values calculated using syngo. via (Hudobivnik) against reference values were 1.0% (0.7%). This difference excludes the lung inserts as the syngo. via method does not provide Z(eff) values for CT numbers < -500 HU. An analysis of the head phantom showed overall a good agreement with all RSP differences within 1% between the syngo. via and Hudobivnik methods. The use of clinically available syngo. via provides equivalent accuracy as a validated RSP calculation method.
引用
收藏
页码:1619 / 1623
页数:5
相关论文
共 50 条
  • [41] Reply to 'Comment on "Experimental verification of ion stopping power prediction from dual energy CT data in tissue surrogates"'
    Huenemohr, Nora
    Niebuhr, Nina
    Greilich, Steffen
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (22): : 7085 - 7087
  • [42] Feasibility study of using triple-energy CT images for improving stopping power estimation
    Kim, Yejin
    Kim, Jin Sung
    Cho, Seungryong
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (04) : 1342 - 1349
  • [43] Dosimetric comparison of stopping power calibration with dual-energy CT and single-energy CT in proton therapy treatment planning
    Zhu, Jiahua
    Penfold, Scott N.
    MEDICAL PHYSICS, 2016, 43 (06) : 2845 - 2854
  • [44] A simulation study on proton computed tomography ( CT) stopping power accuracy using dual energy CT scans as benchmark
    Hansen, David C.
    Seco, Joao
    Sorensen, Thomas Sangild
    Petersen, Jorgen Breede Baltzer
    Wildberger, Joachim E.
    Verhaegen, Frank
    Landry, Guillaume
    ACTA ONCOLOGICA, 2015, 54 (09) : 1638 - 1642
  • [45] Experimental Comparison of Proton CT and Dual Energy X-Ray CT in Terms of Relative Stopping Power Accuracy
    Dedes, G.
    Dickmann, J.
    Wesp, P.
    Johnson, R.
    Pankuch, M.
    Bashkirov, V.
    Schulte, R.
    Landry, G.
    Parodi, K.
    MEDICAL PHYSICS, 2019, 46 (06) : E127 - E127
  • [46] Dual energy CT in radiotherapy: principles and potential
    Greilich, S.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S2 - S2
  • [47] Calibration of the Error from Spectrum Estimation for a Dual Energy CT
    Zheng, Peng
    Xing, Yuxiang
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3591 - 3595
  • [48] Comparison of single and dual energy CT for stopping power determination in proton therapy of head and neck cancer
    Taasti, Vicki Trier
    Muren, Ludvig Paul
    Jensen, Kenneth
    Petersen, Jorgen Breede Baltzer
    Thygesen, Jesper
    Tietze, Anna
    Grau, Cai
    Hansen, David Christoffer
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2018, 6 : 14 - 19
  • [49] Dual-energy CT-based stopping power prediction for dental materials in particle therapy
    Longarino, Friderike K.
    Herpel, Christopher
    Tessonnier, Thomas
    Mein, Stewart
    Ackermann, Benjamin
    Debus, Juergen
    Schwindling, Franz Sebastian
    Stiller, Wolfram
    Mairani, Andrea
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (08):
  • [50] Study of Dual Energy CT Based Proton Stopping Power Ratio Determination in Small Anatomic Structures
    Polf, J.
    Mille, M.
    Mossahebi, S.
    Chen, H.
    Maggi, P.
    Chen-Mayer, H.
    MEDICAL PHYSICS, 2019, 46 (06) : E148 - E148