EVALUATING CLINICAL STOPPING POWER ESTIMATION FROM A RADIOTHERAPY DUAL ENERGY CT SCANNER

被引:3
|
作者
Almeida, Isabel P. [1 ]
Landry, Guillaume [2 ]
Dedes, George [2 ]
Patel, Rakesh [3 ]
Pankuch, Mark [4 ]
Coutrakon, George [5 ]
Schulte, Reinhard [6 ]
Verhaegen, Frank [1 ]
Parodi, Katia [2 ]
Roeske, John C. [3 ]
机构
[1] Maastricht Univ, Med Ctr, GROW Sch Oncol & Dev Biol, Dept Radiat Oncol MAASTRO, Maastricht, Netherlands
[2] Ludwig Maximilians Univ Munchen, Fac Phys, Dept Med Phys, Garching, Germany
[3] Loyola Univ Chicago, Stritch Sch Med, Dept Radiat Oncol, Div Med Phys, Maywood, IL USA
[4] Northwestern Med Chicago Proton Ctr, Warrenville, IL USA
[5] Northern Illinois Univ, Dept Phys, De Kalb, IL USA
[6] Loma Linda Univ, Div Biomed Sci, Loma Linda, CA 92350 USA
来源
ACTA PHYSICA POLONICA B | 2017年 / 48卷 / 10期
关键词
BEAM;
D O I
10.5506/APhysPolB.48.1619
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The use of dual energy computed tomography (DECT) is increasingly considered in particle therapy (PT) to reduce the range of uncertainties attributed to the conversion of X-ray linear attenuation coefficients into relative stopping power (RSP). DECT scanners equipped with clinically available image conversion software can now be found in PT centers. In this work, RSP calculated on the basis of clinical DECT scanner software (syngo. via) was compared to a validated published procedure (Hudobivnik) for calibration and pediatric head phantoms. Based on material inserts, the average difference between RSP values calculated using syngo. via (Hudobivnik) against reference values were 1.0% (0.7%). This difference excludes the lung inserts as the syngo. via method does not provide Z(eff) values for CT numbers < -500 HU. An analysis of the head phantom showed overall a good agreement with all RSP differences within 1% between the syngo. via and Hudobivnik methods. The use of clinically available syngo. via provides equivalent accuracy as a validated RSP calculation method.
引用
收藏
页码:1619 / 1623
页数:5
相关论文
共 50 条
  • [21] Experimental verification of ion stopping power prediction from dual energy CT data in tissue surrogates
    Farace, Paolo
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (22): : 7081 - 7084
  • [22] Experimental verification of ion stopping power prediction from dual energy CT data in tissue surrogates
    Huenemohr, Nora
    Krauss, Bernhard
    Tremmel, Christoph
    Ackermann, Benjamin
    Jaekel, Oliver
    Greilich, Steffen
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (01): : 83 - 96
  • [23] Simplified derivation of stopping power ratio in the human body from dual-energy CT data
    Saito, Masatoshi
    Sagara, Shota
    MEDICAL PHYSICS, 2017, 44 (08) : 4179 - 4187
  • [24] Dual Energy CT Proton Stopping Power Ratio Calibration and Validation with Animal Tissues
    Xie, Y.
    Yin, L.
    Ainsley, C.
    McDonough, J.
    Solberg, T.
    Lin, A.
    Teo, B.
    MEDICAL PHYSICS, 2016, 43 (06) : 3756 - 3756
  • [25] Dual energy CT proton stopping power ratio calibration: Validation with animal tissues
    Xie, Y.
    Yin, L.
    Ainsley, C.
    McDonough, J.
    Solberg, T.
    Lin, A.
    Teo, B. K.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S35 - S36
  • [26] Experimental validation of proton stopping power calculations based on dual energy CT imaging
    Van Abbema, J. K.
    Van Goethem, M. J.
    Mulder, J.
    Biegun, A. K.
    Greuter, M. J. W.
    Van der Schaaf, A.
    Brandenburg, S.
    Van der Graaf, E. R.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S271 - S272
  • [27] Optimal energy selection for proton stopping-power-ratio estimation using dual-energy CT-based monoenergetic imaging
    Je, Euikyu
    Lee, Hugh H. C.
    Duan, Xinhui
    Li, Bin
    Jia, Xun
    Yang, Ming
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (19):
  • [28] Systematic analysis of the impact of imaging noise on dual-energy CT-based proton stopping power ratio estimation
    Lee, Hugh H. C.
    Li, Bin
    Duan, Xinhui
    Zhou, Linghong
    Jia, Xun
    Yang, Ming
    MEDICAL PHYSICS, 2019, 46 (05) : 2251 - 2263
  • [29] Convolutional neural network based proton stopping-power-ratio estimation with dual-energy CT: a feasibility study
    Lee, H. Hc
    Park, Y. K.
    Duan, X.
    Jia, X.
    Jiang, S.
    Yang, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (21):
  • [30] Sparse Dictionary Method for Material Elemental Decomposition in Dual and Multi-Energy CT for Proton Stopping Power Ratio Estimation
    Shen, C.
    Li, B.
    Chen, L.
    Wang, J.
    Yang, M.
    Lou, Y.
    Jia, X.
    MEDICAL PHYSICS, 2017, 44 (06) : 3278 - 3278