EVALUATING CLINICAL STOPPING POWER ESTIMATION FROM A RADIOTHERAPY DUAL ENERGY CT SCANNER

被引:3
|
作者
Almeida, Isabel P. [1 ]
Landry, Guillaume [2 ]
Dedes, George [2 ]
Patel, Rakesh [3 ]
Pankuch, Mark [4 ]
Coutrakon, George [5 ]
Schulte, Reinhard [6 ]
Verhaegen, Frank [1 ]
Parodi, Katia [2 ]
Roeske, John C. [3 ]
机构
[1] Maastricht Univ, Med Ctr, GROW Sch Oncol & Dev Biol, Dept Radiat Oncol MAASTRO, Maastricht, Netherlands
[2] Ludwig Maximilians Univ Munchen, Fac Phys, Dept Med Phys, Garching, Germany
[3] Loyola Univ Chicago, Stritch Sch Med, Dept Radiat Oncol, Div Med Phys, Maywood, IL USA
[4] Northwestern Med Chicago Proton Ctr, Warrenville, IL USA
[5] Northern Illinois Univ, Dept Phys, De Kalb, IL USA
[6] Loma Linda Univ, Div Biomed Sci, Loma Linda, CA 92350 USA
来源
ACTA PHYSICA POLONICA B | 2017年 / 48卷 / 10期
关键词
BEAM;
D O I
10.5506/APhysPolB.48.1619
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The use of dual energy computed tomography (DECT) is increasingly considered in particle therapy (PT) to reduce the range of uncertainties attributed to the conversion of X-ray linear attenuation coefficients into relative stopping power (RSP). DECT scanners equipped with clinically available image conversion software can now be found in PT centers. In this work, RSP calculated on the basis of clinical DECT scanner software (syngo. via) was compared to a validated published procedure (Hudobivnik) for calibration and pediatric head phantoms. Based on material inserts, the average difference between RSP values calculated using syngo. via (Hudobivnik) against reference values were 1.0% (0.7%). This difference excludes the lung inserts as the syngo. via method does not provide Z(eff) values for CT numbers < -500 HU. An analysis of the head phantom showed overall a good agreement with all RSP differences within 1% between the syngo. via and Hudobivnik methods. The use of clinically available syngo. via provides equivalent accuracy as a validated RSP calculation method.
引用
收藏
页码:1619 / 1623
页数:5
相关论文
共 50 条
  • [31] An Efficient Transformer Model for Synthesizing Dual Energy CT from Single Energy Scanner
    Sun, L.
    Zhao, W.
    Lyu, T.
    Chen, Y.
    Xing, L.
    Liu, W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E721 - E722
  • [32] Evaluation of Range Prediction Based On Stopping Power Ratio Images Constructed From Dual-Energy CT
    Mossahebi, S.
    Sabouri, P.
    Polf, J.
    Langner, U.
    Langen, K.
    MEDICAL PHYSICS, 2018, 45 (06) : E440 - E440
  • [33] Dual Energy CT Applications in Radiotherapy
    O'Reilly, Shannon
    Lalonde, Arthur
    Teo, B.
    Miller, J.
    MEDICAL PHYSICS, 2020, 47 (06) : E363 - E363
  • [34] Learning-based synthetic dual energy CT imaging from single energy CT for stopping power ratio calculation in proton radiation therapy
    Charyyev, Serdar
    Wang, Tonghe
    Lei, Yang
    Ghavidel, Beth
    Beitler, Jonathan J.
    McDonald, Mark
    Curran, Walter J.
    Liu, Tian
    Zhou, Jun
    Yang, Xiaofeng
    BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1129):
  • [35] Synthetic Dual Energy CT Images From Single Energy CT Image for Proton Radiotherapy
    Charyyev, S.
    Wang, T.
    Lei, Y.
    Ghavidel, B. Bradshaw
    Beitler, J.
    McDonald, M.
    Curran, W.
    Liu, T.
    Zhou, J.
    Yang, X.
    MEDICAL PHYSICS, 2020, 47 (06) : E378 - E379
  • [36] Reduction of clinical safety margins in proton therapy enabled by the clinical implementation of dual-energy CT for direct stopping-power prediction
    Peters, Nils
    Wohlfahrt, Patrick
    Hofmann, Christian
    Moehler, Christian
    Menkel, Stefan
    Tschiche, Maria
    Krause, Mechthild
    Troost, Esther G. C.
    Enghardt, Wolfgang
    Richter, Christian
    RADIOTHERAPY AND ONCOLOGY, 2022, 166 : 71 - 78
  • [37] Comprehensive analysis of proton range uncertainties related to stopping-power-ratio estimation using dual-energy CT imaging
    Li, B.
    Lee, H. C.
    Duan, X.
    Shen, C.
    Zhou, L.
    Jia, X.
    Yang, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (17): : 7056 - 7074
  • [38] Comprehensive Analysis of Proton Range Uncertainties Related to Stopping-Power-Ratio Estimation Using Dual-Energy CT Imaging
    Li, B.
    Duan, X.
    Shen, C.
    Jia, X.
    Yang, M.
    MEDICAL PHYSICS, 2017, 44 (06) : 2992 - 2992
  • [39] Stopping-power ratio estimation for proton radiotherapy using dual-energy computed tomography and prior-image constrained denoising
    Zimmerman, Jens
    Thor, Daniel
    Poludniowski, Gavin
    MEDICAL PHYSICS, 2023, 50 (03) : 1481 - 1495
  • [40] Ex vivo validation of a stoichiometric dual energy CT proton stopping power ratio calibration
    Xie, Yunhe
    Ainsley, Christopher
    Yin, Lingshu
    Zou, Wei
    McDonough, James
    Solberg, Timothy D.
    Lin, Alexander
    Teo, Boon-Keng Kevin
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (05):