Dual robot system for upper after stroke: the design limb rehabilitation process

被引:0
|
作者
Jackson, A. E.
Holt, R. J.
Culmer, P. R.
Makower, S. G.
Levesley, M. C.
Richardson, R. C.
Cozens, J. A.
Williams, M. Mon
Bhakta, B. B.
机构
[1] Univ Leeds, Sch Mech Engn, Dept Mech Engn, Leeds LS2 9JT, W Yorkshire, England
[2] Leeds Primary Care NHS Trust, Leeds, W Yorkshire, England
[3] Univ Manchester, Dept Comp Sci, Manchester, Lancs, England
[4] Grampian NHS, Dept Rehabil Med, Grampian, Scotland
[5] Univ Aberdeen, Dept Psychol, Aberdeen, Scotland
[6] Univ Leeds, Fac Med Hlth, Leeds, W Yorkshire, England
[7] Leeds Teaching Hosp NHS Trust, Leeds, W Yorkshire, England
关键词
robotic; rehabilitation; design; user involvement; stroke; upper limb; stakeholder analysis;
D O I
10.1243/0954406JMES561
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Stroke is the most common cause of severe disability in the UK. Arm impairment is common and recovery is partly dependent on the intensity and frequency of rehabilitation intervention. However, physical therapy resources are often limited, so methods of supplementing traditional physiotherapy are essential. Robot assisted physiotherapy is one way to increase the duration patients spend participating in rehabilitation activities. A single robot system has been developed at the University of Leeds that actively assists patients undertaking therapeutic movements in a three-dimensional workspace. However, using only a single point of contact at the wrist to assist with therapeutic reaching movements does not allow control or support of the more proximal joints of the upper limb. This could lead to discomfort during assisted exercise. In addition, the design suffers from a restrictive workspace, limiting the range of therapeutic exercise that can be undertaken. To address these limitations, the intelligent Pneumatic Arm Movement system has been developed. A major aspect of the development process has been the continual involvement of physiotherapists and stroke patients; the end users of the system. Through inclusion of these stakeholders, a system has been developed that satisfies their requirements for workspace, comfort, safety, and ease of use.
引用
收藏
页码:845 / 857
页数:13
相关论文
共 50 条
  • [31] Structural design of an escort type rehabilitation robot for post-stroke therapies of upper-limb
    Nagai, Kiyoshi
    Kojima, Yoshimasa
    Yonemoto, Shinya
    Okubo, Takashi
    Loureiro, Rui C. V.
    Harwin, William S.
    2007 IEEE 10TH INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS, VOLS 1 AND 2, 2007, : 1121 - +
  • [32] A Neuromuscular Electrical Stimulation (NMES) and robot hybrid system for multi-joint coordinated upper limb rehabilitation after stroke
    Rong, Wei
    Li, Waiming
    Pang, Mankit
    Hu, Junyan
    Wei, Xijun
    Yang, Bibo
    Wai, Honwah
    Zheng, Xiaoxiang
    Hu, Xiaoling
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2017, 14
  • [33] A Neuromuscular Electrical Stimulation (NMES) and robot hybrid system for multi-joint coordinated upper limb rehabilitation after stroke
    Wei Rong
    Waiming Li
    Mankit Pang
    Junyan Hu
    Xijun Wei
    Bibo Yang
    Honwah Wai
    Xiaoxiang Zheng
    Xiaoling Hu
    Journal of NeuroEngineering and Rehabilitation, 14
  • [34] Protocol for a feasibility study of OnTrack: a digital system for upper limb rehabilitation after stroke
    Fusari, Gianpaolo
    Gibbs, Ella
    Hoskin, Lily
    Dickens, Daniel
    Leis, Melanie
    Taylor, Elizabeth
    Jones, Fiona
    Darzi, Ara
    BMJ OPEN, 2020, 10 (03): : e034936
  • [35] Robot-Assisted Upper and Lower Limb Rehabilitation After Stroke Walking and Arm/Hand Function
    Hesse, Stefan
    Mehrholz, Jan
    Werner, Cordula
    DEUTSCHES ARZTEBLATT INTERNATIONAL, 2008, 105 (18): : 330 - 336
  • [36] Design of ELISE robot for the paretic upper limb of stroke survivors
    Tutak, Jacek S.
    JOURNAL OF VIBROENGINEERING, 2016, 18 (06) : 4069 - 4085
  • [37] The LabVIEW -Based Control System for the Upper Limb Rehabilitation Robot
    Guo, Shuxiang
    Gao, Jiange
    Guo, Jian
    Li, Nan
    2017 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), 2017, : 1732 - 1737
  • [38] Development of an Upper Limb Rehabilitation Robot System for Bilateral Training
    Wei, Wei
    Zhang, Wu
    Guo, Shuxiang
    Zhao, Xin
    Wang, Yunliang
    2014 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (IEEE ICMA 2014), 2014, : 930 - 935
  • [39] An Integrated Software System Designed for Upper Limb Rehabilitation Robot
    Cen, Yuhui
    Yuan, Jianjun
    Bao, Sheng
    Du, Liang
    Ma, Shugen
    Wan, Weiwei
    2021 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (IEEE-ROBIO 2021), 2021, : 1228 - 1233
  • [40] Enhancing Upper Limb Function and Motor Skills Post-Stroke Through an Upper Limb Rehabilitation Robot
    Zhang, Tianfang
    Yao, Zhao
    Chen, Fenfen
    Wang, Jie
    Shi, Weiyi
    Zheng, Jinjin
    Zhang, Ziwei
    Chen, Zuobing
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (211):