SEISMIC ANALYSIS OF GUANG DONG SCIENCE CENTRE WITH OR WITHOUT BASE-ISOLATION: A CASE STUDY

被引:0
|
作者
Zhu, Yong [1 ]
Su, R. K. L.
Zhang, Ji Chao [1 ]
机构
[1] Guangzhou Univ, Sch Civil Engn, Guangzhou, Guangdong, Peoples R China
关键词
damper; isolator; mega-frame; response spectrum; seismic analysis; time history analysis;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Guang Dong Science Centre (GDSC), located in the west of Guang Zhou Mega University City, is currently one of the most important landmark buildings in Guang Zhou of Guang Dong province. The special form and style, and the use of mega-frame and long-span internal space of the building, not surprisingly, presented great challenges for structural engineers. In particular, its dynamic performance under earthquake or wind actions requires intensive research. In this study, a detailed seismic analysis of GDSC has been conducted to investigate GDSC's seismic performance with or without the application of base-isolation. In this analysis, earthquake spectra generated for Guang Zhou region according to Chinese Code and Component Attenuation Method (CAM) were adopted to calculate the lateral displacements and distributions of base column forces. Furthermore, elastic and inelastic time-history seismic analyses were carried out using scaled accelerograms representing earthquake events with return periods of 50-year, 475-year, and 2475-years, respectively. The computational results indicate that the building with mega-frame system possesses substantial reserved strength for resisting earthquake loads, and the structure could satisfy the design requirements under severe seismic events. The output of this study is of considerable interest and practical use to professionals and researchers involving in the design of mega-frame buildings.
引用
收藏
页码:417 / 423
页数:7
相关论文
共 50 条
  • [31] Interactive base-isolation foundation system: II. Parametric study
    Ahn, Ki Jun
    Gould, Phillip L.
    Journal of Engineering Mechanics, 1992, 118 (10) : 2059 - 2071
  • [32] Experimental and theoretical study on vibration control of base-isolation with energy transducer
    Cheng, Shu-Liang
    Xin, Ya-Jun
    Wang, Huan-Ding
    Journal of Harbin Institute of Technology (New Series), 2009, 16 (02) : 165 - 171
  • [33] Bio-Inspired Passive Optimized Base-Isolation System for Seismic Mitigation of Building Structures
    Chen, Xi
    Yang, Henry T. Y.
    Shan, Jiazeng
    Hansma, Paul K.
    Shi, Weixing
    JOURNAL OF ENGINEERING MECHANICS, 2016, 142 (01)
  • [34] INTERACTIVE BASE-ISOLATION FOUNDATION SYSTEM .2. PARAMETRIC STUDY
    KI, JA
    GOULD, PL
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 1992, 118 (10): : 2059 - 2071
  • [35] Seismic retrofitting by base-isolation of r.c. framed buildings exposed to different fire scenarios
    Mazza, Fabio
    Mazza, Mirko
    EARTHQUAKES AND STRUCTURES, 2017, 13 (03) : 267 - 277
  • [36] Comparative Study of Smart Base-Isolation Using Fuzzy Control and Neural Network
    Lakhani, Megha T.
    Soni, Devesh P.
    PLASTICITY AND IMPACT MECHANICS, 2017, 173 : 1825 - 1832
  • [37] Experimental study on effect of energy transition of base-isolation with energy transducer system
    Cheng, Shu-Liang
    Wang, Huan-Ding
    Sun, Zuo-Yu
    Gongcheng Lixue/Engineering Mechanics, 2006, 23 (11): : 38 - 44
  • [38] ANALYSIS OF P-Δ EFFECTS IN CANTILEVER BASEMENT COLUMN OF THE BASE-ISOLATION SYSTEM
    Li Hui
    Zhang Huaying
    Zhang Xin
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON INSPECTION APPRAISAL REPAIRS AND MAINTENANCE OF STRUCTURES, VOLS 1 AND 2, 2010, : 569 - +
  • [40] Seismic Performance of Base-isolation Building Subjected to Near-fault Ground Motion with Velocity Pulse
    He Qiumei
    Li Yaqi
    Zhao Yamin
    Yang Yu
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING IV, 2014, 580-583 : 1700 - +