SEISMIC ANALYSIS OF GUANG DONG SCIENCE CENTRE WITH OR WITHOUT BASE-ISOLATION: A CASE STUDY

被引:0
|
作者
Zhu, Yong [1 ]
Su, R. K. L.
Zhang, Ji Chao [1 ]
机构
[1] Guangzhou Univ, Sch Civil Engn, Guangzhou, Guangdong, Peoples R China
关键词
damper; isolator; mega-frame; response spectrum; seismic analysis; time history analysis;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Guang Dong Science Centre (GDSC), located in the west of Guang Zhou Mega University City, is currently one of the most important landmark buildings in Guang Zhou of Guang Dong province. The special form and style, and the use of mega-frame and long-span internal space of the building, not surprisingly, presented great challenges for structural engineers. In particular, its dynamic performance under earthquake or wind actions requires intensive research. In this study, a detailed seismic analysis of GDSC has been conducted to investigate GDSC's seismic performance with or without the application of base-isolation. In this analysis, earthquake spectra generated for Guang Zhou region according to Chinese Code and Component Attenuation Method (CAM) were adopted to calculate the lateral displacements and distributions of base column forces. Furthermore, elastic and inelastic time-history seismic analyses were carried out using scaled accelerograms representing earthquake events with return periods of 50-year, 475-year, and 2475-years, respectively. The computational results indicate that the building with mega-frame system possesses substantial reserved strength for resisting earthquake loads, and the structure could satisfy the design requirements under severe seismic events. The output of this study is of considerable interest and practical use to professionals and researchers involving in the design of mega-frame buildings.
引用
收藏
页码:417 / 423
页数:7
相关论文
共 50 条
  • [21] Low Cost Friction Seismic Base-Isolation of Residential New Masonry Buildings in Developing Countries: a Small Masonry House Case Study
    Habieb, A. B.
    Milani, G.
    Tavio, T.
    Milani, F.
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON NUMERICAL ANALYSIS AND APPLIED MATHEMATICS 2016 (ICNAAM-2016), 2017, 1863
  • [22] Seismic fragility analysis of base-isolation structure connected with large span special-shaped steel corridor
    Pan, Yi
    Bao, Yunlei
    Liu, Yongxin
    Hu, Siyuan
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2021, 54 (02): : 20 - 29
  • [23] Seismic rehabilitation of masonry heritage structures with base-isolation and with selected contemporary strengthening measures
    Kilar V.
    Petrovčič S.
    International Journal of Safety and Security Engineering, 2017, 7 (04) : 475 - 485
  • [24] Passive combined control of the seismic response of structures by use of base-isolation and TMD system
    Zhu, HP
    Tang, JX
    Kuang, JS
    STRUCTURES IN THE NEW MILLENNIUM, 1997, : 567 - 574
  • [25] EFFECTIVENESS OF BLOCK ITERATIVE SCHEMES IN COMPUTING THE SEISMIC RESPONSE OF BUILDINGS WITH NONLINEAR BASE-ISOLATION
    BARBAT, AH
    MOLINARES, N
    CODINA, R
    COMPUTERS & STRUCTURES, 1996, 58 (01) : 133 - 141
  • [27] Stress analysis of RC Column under the Isolator in the Base-Isolation System
    Zhang Huaying
    Pan Ruisong
    MECHATRONICS AND INTELLIGENT MATERIALS II, PTS 1-6, 2012, 490-495 : 1531 - +
  • [28] DYNAMIC ANALYSIS OF A SMART BASE-ISOLATION SYSTEM BASED ON MR ELASTOMERS
    Jung, Hyung-Jo
    Park, Jeong-Su
    Koo, Jeong-Hoi
    PROCEEDINGS OF THE ASME CONFERENCE ON SMART MATERIALS, ADAPTIVE STRUCTURES AND INTELLIGENT SYSTEMS, 2010, VOL 2, 2010, : 413 - 418
  • [29] Analysis about the Damping Function of Base-Isolation with Different Friction Coefficient
    Sun, Na
    Liu, Zhao-Jun
    PROCEEDINGS OF THE FOURTH INTERNATIONAL CONFERENCE OF MODELLING AND SIMULATION (ICMS2011), VOL 1, 2011, : 379 - 382
  • [30] Experimental and theoretical study on vibration control of base-isolation with energy transducer
    程树良
    辛亚军
    王焕定
    Journal of Harbin Institute of Technology(New series), 2009, (02) : 165 - 171