A simpler device for measuring the mobility of the first ray of the foot

被引:14
|
作者
Kim, J-Young [1 ]
Hwang, Seung Keun [1 ]
Lee, Kyung Tai [1 ]
Young, Ki Won [1 ]
Jung, Ju Seon [1 ]
机构
[1] Eulji Med Ctr, Foot & Ankle Clin, DMF & Wound Healing Part, Seoul 139711, South Korea
关键词
mobility of the first ray; EMC device; validity; reliability;
D O I
10.3113/FAI.2008.0213
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Since some devices can be cumbersome to use, we evaluated the validity and reliability of a specially designed device for easily checking the mobility of the first ray of the foot. Materials and Methods: To analyze the validity of the device, the dorsal mobility of the first ray of the foot was measured with the modified Coleman block test developed by Fritz et al., the Klaue device, and the custom device. Two-tailed Student's paired t-test and Pearson correlation were used to compare the values of the two tests. For evaluation of inter- and intra observer reliability of the EMC device, 3 independent observers measured the dorsal mobility of the first ray of the foot twice. The results were analyzed with two-tailed Student's paired t-test and ANOVA to evaluate intraobserver and interobserver reliability, respectively. Results: For both the first and second examinations of reliability, the difference between the two values was significant (p < 0.05) for the Coleman block test but not significant (p = 0.118) in comparison with the Mane device. The measurements from both examinations showed good correlation (Pearson correlation coeffcient: comparison with the Coleman block test = 0.84 (p < 0.05), with the Klaue device = 0.92 (p < 0.05)). The paired t-test for intraobserver validity showed no statistically significant difference among observers (p = 0.52, 0.58, 0.96, Pearson correlation coefficient = 0.76, 0.79, 0.80), and ANOVA testing for interobserver reliability showed no significant difference either (p = 0.96, Pearson correlation coefficients = 0.83, 0.84, and 0.86, respectively). Conclusion: This study demonstrated that the EMC device is both reliable and valid for measuring the mobility of the first ray of the foot.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 50 条
  • [31] FOOT-FORCE MEASURING DEVICE FOR CLINICAL-ASSESSMENT OF PATHOLOGICAL GAIT
    MIYAZAKI, S
    IWAKURA, H
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1978, 16 (04) : 429 - 436
  • [32] ANTHROPOMETRICAL AND ORTHOPEDICAL APPLICATIONS OF A MEASURING DEVICE FOR THE PRESSURE-DISTRIBUTION UNDER THE FOOT
    HEIDINGER, F
    KURZ, B
    SELBACH, R
    DIEBSCHLAG, W
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1987, 125 (02): : 201 - 205
  • [33] Variation In The Angle Of The First Pedal Ray Relative To The Midline Of The Foot
    Whitman, Paige S.
    Lautzenheiser, Steven G.
    Kramer, Patricia Ann
    Harper, Christine M.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2024, 56 (10) : 57 - 58
  • [34] Relationship between static mobility of the first ray and first ray, midfoot, and hindfoot motion during gait
    Allen, MK
    Cuddeford, TJ
    Glasoe, WM
    DeKam, LM
    Lee, PJ
    Wagner, KJ
    Yack, HJ
    FOOT & ANKLE INTERNATIONAL, 2004, 25 (06) : 391 - 396
  • [35] MEASURING AND CENTERING DEVICE FOR USE ON X-RAY MACHINE
    ROSS, MS
    AMA ARCHIVES OF DERMATOLOGY AND SYPHILOLOGY, 1952, 65 (02): : 231 - 232
  • [36] DETERMINATION OF ELECTROPHORETIC MOBILITY OF FOOT AND MOUTH DISEASE VIRUS IN AGAR GEL BY MEASURING RADIOACTIVITY
    MATTHAEU.W
    ZENTRALBLATT FUR BAKTERIOLOGIE PARASITENKUNDE INFEKTIONSKRANKHEITEN UND HYGIENE ABTEILUNG 1, 1967, 204 (02): : 161 - &
  • [37] A simpler sieving device:: Combining ECM and TWIRL
    Geiselmann, Willi
    Januszewski, Fabian
    Koepfer, Hubert
    Pelzl, Jan
    Steinwandt, Rainer
    Information Security and Cryptology - ICISC 2006, Proceedings, 2006, 4296 : 118 - 135
  • [38] MOBILITY OF THE ARCH OF THE FOOT
    LOCKHART, RD
    JOURNAL OF ANATOMY, 1958, 92 (04) : 666 - 667
  • [39] DEVICE FOR MEASURING HALL-MOBILITY OF THIN-FILMS AT SPRAY COATING
    LABUNOV, VA
    KOLOSNIT.BS
    ZAVODSKAYA LABORATORIYA, 1973, (06): : 760 - 762
  • [40] Hallux vaigus and first ray mobility. A prospective study
    Greisberg, Justin K.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (05): : 1166 - 1166