A simpler device for measuring the mobility of the first ray of the foot

被引:14
|
作者
Kim, J-Young [1 ]
Hwang, Seung Keun [1 ]
Lee, Kyung Tai [1 ]
Young, Ki Won [1 ]
Jung, Ju Seon [1 ]
机构
[1] Eulji Med Ctr, Foot & Ankle Clin, DMF & Wound Healing Part, Seoul 139711, South Korea
关键词
mobility of the first ray; EMC device; validity; reliability;
D O I
10.3113/FAI.2008.0213
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Since some devices can be cumbersome to use, we evaluated the validity and reliability of a specially designed device for easily checking the mobility of the first ray of the foot. Materials and Methods: To analyze the validity of the device, the dorsal mobility of the first ray of the foot was measured with the modified Coleman block test developed by Fritz et al., the Klaue device, and the custom device. Two-tailed Student's paired t-test and Pearson correlation were used to compare the values of the two tests. For evaluation of inter- and intra observer reliability of the EMC device, 3 independent observers measured the dorsal mobility of the first ray of the foot twice. The results were analyzed with two-tailed Student's paired t-test and ANOVA to evaluate intraobserver and interobserver reliability, respectively. Results: For both the first and second examinations of reliability, the difference between the two values was significant (p < 0.05) for the Coleman block test but not significant (p = 0.118) in comparison with the Mane device. The measurements from both examinations showed good correlation (Pearson correlation coeffcient: comparison with the Coleman block test = 0.84 (p < 0.05), with the Klaue device = 0.92 (p < 0.05)). The paired t-test for intraobserver validity showed no statistically significant difference among observers (p = 0.52, 0.58, 0.96, Pearson correlation coefficient = 0.76, 0.79, 0.80), and ANOVA testing for interobserver reliability showed no significant difference either (p = 0.96, Pearson correlation coefficients = 0.83, 0.84, and 0.86, respectively). Conclusion: This study demonstrated that the EMC device is both reliable and valid for measuring the mobility of the first ray of the foot.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 50 条
  • [21] The Design of Simulating Different Altitudes Ionic Mobility Measuring Device
    Lu, Fangcheng
    Geng, Qingzhong
    Liu, Yunpeng
    MEASUREMENT TECHNOLOGY AND ENGINEERING RESEARCHES IN INDUSTRY, PTS 1-3, 2013, 333-335 : 157 - 160
  • [22] A Novel Classification for Diabetic Foot Ulcers of the First Ray
    Tamir, Eran
    Rabau, Oded
    Beer, Yiftah
    Smorgick, Yossi
    Kaufman, Hanna
    Finestone, Aharon S.
    ADVANCES IN SKIN & WOUND CARE, 2023, 36 (01) : 30 - 34
  • [23] K-SQUARE - NEW BIOMECHANICAL MEASURING DEVICE FOR THE FOOT AND ANKLE
    KAYE, JM
    SORTO, LA
    JOURNAL OF THE AMERICAN PODIATRY ASSOCIATION, 1979, 69 (01): : 58 - 64
  • [24] A MEASURING DEVICE AND PROCEDURE FOR X-RAY FILMS
    ARUJA, E
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1963, 40 (05): : 263 - &
  • [25] The reliability and validity of a first ray measurement device
    Glasoe, WM
    Yack, HJ
    Saltzman, CL
    FOOT & ANKLE INTERNATIONAL, 2000, 21 (03) : 240 - 246
  • [26] A MINIATURE ELECTRET-BASED DEVICE FOR MEASURING THE ELECTRICAL MOBILITY OF AEROSOLS
    HEMINGWAY, MA
    BROWN, RC
    JOURNAL OF AEROSOL SCIENCE, 1995, 26 (02) : 241 - &
  • [27] The effect of ankle position on the exam for first ray mobility
    Grebing, BR
    Coughlin, MJ
    FOOT & ANKLE INTERNATIONAL, 2004, 25 (07) : 467 - 475
  • [28] Hallux valgus and first ray mobility - A prospective study
    Coughlin, Michael J.
    Jones, Carroll P.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (09): : 1887 - 1898
  • [29] Hallux valgus and first ray mobility:: A cadaveric study
    Coughlin, MJ
    Jones, CP
    Viladot, R
    Glanó, P
    Grebing, BR
    Kennedy, MJ
    Shurnas, PS
    Alvarez, F
    FOOT & ANKLE INTERNATIONAL, 2004, 25 (08) : 537 - 544
  • [30] The Keystone device as a clinical tool for measuring the supination resistance of the foot: A reliability study
    Moisan, Gabriel
    McBride, Sean
    Isabelle, Pier-Luc
    Chicoine, Dominic
    MUSCULOSKELETAL CARE, 2022, 20 (03) : 570 - 576