A simpler device for measuring the mobility of the first ray of the foot

被引:14
|
作者
Kim, J-Young [1 ]
Hwang, Seung Keun [1 ]
Lee, Kyung Tai [1 ]
Young, Ki Won [1 ]
Jung, Ju Seon [1 ]
机构
[1] Eulji Med Ctr, Foot & Ankle Clin, DMF & Wound Healing Part, Seoul 139711, South Korea
关键词
mobility of the first ray; EMC device; validity; reliability;
D O I
10.3113/FAI.2008.0213
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Since some devices can be cumbersome to use, we evaluated the validity and reliability of a specially designed device for easily checking the mobility of the first ray of the foot. Materials and Methods: To analyze the validity of the device, the dorsal mobility of the first ray of the foot was measured with the modified Coleman block test developed by Fritz et al., the Klaue device, and the custom device. Two-tailed Student's paired t-test and Pearson correlation were used to compare the values of the two tests. For evaluation of inter- and intra observer reliability of the EMC device, 3 independent observers measured the dorsal mobility of the first ray of the foot twice. The results were analyzed with two-tailed Student's paired t-test and ANOVA to evaluate intraobserver and interobserver reliability, respectively. Results: For both the first and second examinations of reliability, the difference between the two values was significant (p < 0.05) for the Coleman block test but not significant (p = 0.118) in comparison with the Mane device. The measurements from both examinations showed good correlation (Pearson correlation coeffcient: comparison with the Coleman block test = 0.84 (p < 0.05), with the Klaue device = 0.92 (p < 0.05)). The paired t-test for intraobserver validity showed no statistically significant difference among observers (p = 0.52, 0.58, 0.96, Pearson correlation coefficient = 0.76, 0.79, 0.80), and ANOVA testing for interobserver reliability showed no significant difference either (p = 0.96, Pearson correlation coefficients = 0.83, 0.84, and 0.86, respectively). Conclusion: This study demonstrated that the EMC device is both reliable and valid for measuring the mobility of the first ray of the foot.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 50 条
  • [11] Low Cost Foot Pressure Measuring Device
    Crisan, Titus E.
    Ardelean, Madalin, I
    Tebrean, Bogdan
    Oltean, Tudor
    PROCEEDINGS OF 9TH INTERNATIONAL CONFERENCE ON MODERN POWER SYSTEMS (MPS 2021), 2021,
  • [12] A device for measuring plantar pressures under the sole of the foot
    Betts, R.P.
    Duckworth, T.
    Engineering in Medicine, 1978, 7 (04): : 223 - 228
  • [13] Hallux Valgus and First Ray Mobility
    Coughlin, Michael J.
    Smith, Bertil W.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A : 153 - 170
  • [14] Mobility of the First Ray: Review Article
    Van Beek, Corinne
    Greisberg, Justin
    FOOT & ANKLE INTERNATIONAL, 2011, 32 (09) : 917 - 922
  • [15] Measuring tooth mobility with a no-contact vibration device
    Yamane, M.
    Yamaoka, M.
    Hayashi, M.
    Furutoyo, I.
    Komori, N.
    Ogiso, B.
    JOURNAL OF PERIODONTAL RESEARCH, 2008, 43 (01) : 84 - 89
  • [16] Rheumatoid flat foot and deformity of the first ray
    Bouysset, M
    Tebib, J
    Noel, E
    Tavernier, T
    Miossec, P
    Vianey, JC
    Duivon, JP
    Bonnin, M
    Nemoz, C
    Jalby, J
    JOURNAL OF RHEUMATOLOGY, 2002, 29 (05) : 903 - 905
  • [17] MEASURING DEVICE FOR THE ANALYSIS OF PRESSURE DISTRIBUTION ON THE FOOT SOLES OF CATTLE
    MAIR, A
    DIEBSCHLAG, W
    DISTL, O
    KRAUSSLICH, H
    JOURNAL OF VETERINARY MEDICINE SERIES A-ZENTRALBLATT FUR VETERINARMEDIZIN REIHE A-PHYSIOLOGY PATHOLOGY CLINICAL MEDICINE, 1988, 35 (09): : 696 - 704
  • [18] A DEVICE FOR MEASURING FORCES ON THE HUMAN CADAVERIC FOOT DURING SUPINATION
    OTTEVANGER, EJC
    SPOOR, CW
    HUSON, A
    JOURNAL OF ANATOMY, 1986, 149 : 246 - 246
  • [19] Application of a system for measuring foot plantar pressure for evaluation of human mobility
    Klimiec, Ewa
    Jasiewicz, Barbara
    Zaraska, Krzysztof
    Piekarski, Jacek
    Guzdek, Piotr
    Kolaszczynski, Grzegorz
    14TH INTERNATIONAL CONFERENCE ON OPTICAL AND ELECTRONIC SENSORS, 2016, 10161
  • [20] First Ray Mobility Increase in Patients With Metatarsalgia
    Greisberg, Justin
    Prince, Daniel
    Sperber, Lisa
    FOOT & ANKLE INTERNATIONAL, 2010, 31 (11) : 954 - 958