T2 weighted liver Magnetic Resonance imaging using functional residual capacity breath-hold with multi breath-hold

被引:0
|
作者
Tabuchi, A. [1 ,2 ]
Katsuda, T. [3 ]
Gotanda, R. [1 ]
Gotanda, T. [1 ]
Yamamoto, K. [1 ,4 ]
Mitani, M. [2 ]
Takeda, Y. [1 ]
机构
[1] Okayama Univ, Grad Sch Hlth Sci, 2-5-1 Shikata Cho, Okayama 7008530, Japan
[2] Kawasaki Med Sch Kawasaki Hosp, Okayama, Japan
[3] Himeji Dokkyo UNiv, Fac High Care Sci, Himeji, Hyogo, Japan
[4] Osaka Canc Prevent & Detect Ctr, Osaka, Japan
关键词
T2 weighted MR imaging; Functional Residual Capacity (FRC); reproducibility; high-resolution; TURBO-SPIN-ECHO; SEQUENCES;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: During acquisition of rapid high resolution (HR) T2 weighted (T2W) liver magnetic resonance (MR) images using a 1.0-Tesla (T) scanner, the liver is segmented into odd and even sections that are acquired at two different times using the multi-breath-hold (MBH) strategy. Misalignment between the two breath-hold (B-H) images may result in the occurrence of a blind area and a decrease in diagnostic accuracy. Here, a functional residual capacity (FRC) B-H method was developed to overcome this problem. Material and methods: Twenty-five volunteers were enrolled. The sagittal images were reconstructed from whole liver transverse images. The misalignments of the abdominal wall were measured in the anterior-posterior (AP) direction and were compared between each two B-H phases, maximum inspiration, maximum expiration, voluntary expiration and FRC using one-way repeated measures ANOVA. Differences between groups were compared using the t-test for multigroup comparisons. In addition, qualitative analysis of misalignment was performed between VE and FRC in 52 clinical patients and the chi(2) test was performed. Results: Misalignment of the liver position using FRC was significantly smaller than the other B-H methods (p < 0.05). Significant differences between the VE B-H and FRC B-H were also observed in the qualitative analysis (p < 0.05).
引用
收藏
页码:1598 / 1602
页数:5
相关论文
共 50 条
  • [31] Pancreatic adenocarcinoma: a pilot study of quantitative perfusion and diffusion-weighted breath-hold magnetic resonance imaging
    Kim, Hyunki
    Arnoletti, Pablo J.
    Christein, John
    Heslin, Martin J.
    Posey, James A., III
    Pednekar, Amol
    Beasley, T. Mark
    Morgan, Desiree E.
    ABDOMINAL IMAGING, 2014, 39 (04): : 744 - 752
  • [32] Effects of Breathing and Breath-hold on Brain Functional Connectivity
    Anusha, A. S.
    Ramakrishnan, A. G.
    Adarsh, A.
    Sharma, Kanishka
    Kumar, G. Pradeep
    2022 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA 2022), 2022,
  • [33] Echo-train STIR MRI of the liver: Comparison of breath-hold and non-breath-hold imaging strategies
    Earls, JP
    Rofsky, NM
    DeCorato, DR
    Krinsky, GA
    Weinreb, JC
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (01): : 87 - 92
  • [34] Expiration Breath-Hold for SBRT in Liver and Abdominal Tumors
    Ehrbar, S.
    Andratschke, N.
    Perryck, S.
    Stussi, A.
    Moreira, A. K.
    Tanadini-Lang, S.
    Guckenberger, M.
    Schuler, H. I. Garcia
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E761 - E761
  • [35] Quantitative assessment of myocardial edema using a breath-hold T2 mapping pulse sequence
    Mansi Shah
    Monvadi B Srichai
    Daniel Kim
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [36] Single breath-hold diffusion-weighted MRI of the liver with parallel imaging: initial experience
    Oner, A. Y.
    Celik, H.
    Oktar, S. O.
    Tali, T.
    CLINICAL RADIOLOGY, 2006, 61 (11) : 959 - 965
  • [37] Pancreatic SABR using peritumoral fiducials, triggered imaging and breath-hold
    Kisivan, Katalin
    Farkas, Andrea
    Kovacs, Peter
    Glavak, Csaba
    Lukacs, Gabor
    Mahr, Karoly
    Szabo, Zsolt
    Csima, Melinda Petone
    Gulyban, Akos
    Toth, Zoltan
    Kaposztas, Zsolt
    Lakosi, Ferenc
    PATHOLOGY & ONCOLOGY RESEARCH, 2023, 29
  • [38] Deep inspiration breath-hold technique using an Arduino
    Gallego, P.
    Perez-Alija, J.
    Olivares, S.
    Loscos, S.
    Ambroa, E.
    Pedro, A.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S811 - S811
  • [39] Breath-hold MR urography using the HASTE technique
    Aerts, P
    VanHoe, L
    Bosmans, H
    Oyen, R
    Marchal, G
    Baert, AL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (03) : 543 - 545
  • [40] FAT-SUPPRESSED BREATH-HOLD MAGNETIC-RESONANCE CORONARY ANGIOGRAPHY
    MANNING, WJ
    LI, W
    BOYLE, NG
    EDELMAN, RR
    CIRCULATION, 1993, 87 (01) : 94 - 104