Echo-train STIR MRI of the liver: Comparison of breath-hold and non-breath-hold imaging strategies

被引:0
|
作者
Earls, JP [1 ]
Rofsky, NM [1 ]
DeCorato, DR [1 ]
Krinsky, GA [1 ]
Weinreb, JC [1 ]
机构
[1] NYU, Med Ctr, Dept Radiol, New York, NY 10016 USA
来源
关键词
liver MRI; inversion recovery; liver neoplasms;
D O I
10.1002/(SICI)1522-2586(199901)9:1<87::AID-JMRI12>3.0.CO;2-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate echo-train short inversion-time inversion recovery (STIR) sequences and compare the results obtained with breath-hold and nonbreath-hold imaging strategies, Forty-one patients referred for hepatic magnetic resonance were imaged with both a breath-hold STIR (BH-STIR; acquisition time [TA] 16-20 seconds x 2) and a non-breath-hold STIR (NBH-STIR; TA 210-256 seconds), Quantitative analysis of the liver, spleen, and up to five hepatic lesions per patient was performed. Three blinded readers recorded the number of focal lesions depicted by each study and qualitatively evaluated overall image quality, lesion conspicuity, and image artifacts, The BH-STIR had greater sensitivity (98.8% vs, 91.6%) for detection of hepatic lesions than the NBH-STIR. The BH-STIR was statistically superior in four measures of image quality and had fewer image artifacts. The NBH-STIR images had statistically higher signal-to-noise (S/N, P < 0.001) and liver-lesion contrast-to-noise (C/N, P = 0.005) ratios, For the evaluation of focal hepatic lesions, a breath-hold echo-train STIR sequence provided superior overall image quality and allowed for detection of more lesions in a shorter amount of time than a non-breath-hold echo-train STIR sequence. J, Magn. Reson. Imaging 1999;9:87-92. (C) 1999 Wiley-Liss, Inc.
引用
收藏
页码:87 / 92
页数:6
相关论文
共 50 条
  • [1] Evaluation of arch vessels: Breath-hold versus non-breath-hold techniques
    Krinsky, G
    RADIOLOGY, 2004, 232 (01) : 303 - 304
  • [2] Phased array breath-hold versus non-breath-hold MR imaging of focal liver lesions: A prospective comparative study
    Yamashita, Y
    Yamamoto, H
    Namimoto, T
    Abe, Y
    Takahashi, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (02): : 292 - 297
  • [3] Non-breath-hold versus breath-hold T2-weighted fast SE imaging of the uterus
    OMalley, JP
    Ascher, SM
    Thomasson, D
    Rajan, SS
    Semelka, RC
    Zeman, RK
    RADIOLOGY, 1996, 201 : 1060 - 1060
  • [4] Abdominal phase contrast MR angiography: Breath-hold versus non-breath-hold techniques
    Hara, AK
    Burkart, DJ
    Johnson, CD
    Ehman, RL
    Ilstrup, DM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (01): : 94 - 98
  • [5] The interaction of breath holding and muscle mechanoreflex on cardiovascular responses in breath-hold divers and non-breath-hold divers
    Nobuhiro, Nakamura
    Heng, Peng
    Naoyuki, Hayashi
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2024, 124 (07) : 2183 - 2192
  • [6] Assessment of myocardial function with interactive non-breath-hold real-time MR imaging:: Comparison with echocardiography and breath-hold cine MR imaging
    Kühl, HP
    Spuentrup, E
    Wall, A
    Franke, A
    Schröder, J
    Heussen, N
    Hanrath, P
    Günther, RW
    Buecker, A
    RADIOLOGY, 2004, 231 (01) : 198 - 207
  • [7] Breath-hold fast recovery fast spin echo versus conventional non-breath-hold fast spin echo T2-weighted MR imaging of focal liver lesions
    Tseng, GY
    Thng, CH
    Wong, EH
    Tan, AGS
    Suman, P
    Quek, ST
    Ho, JTS
    Khoo, JKB
    Ooi, LLPJ
    Chow, PKH
    Chung, YFA
    Teh, CSC
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2003, 32 (04) : 450 - 454
  • [8] MR of focal liver lesions: Comparison of breath-hold and non-breath-hold hybrid RARE and conventional spin-echo T2-weighted pulse sequences
    Carpenter, KD
    Macaulay, SE
    Schulte, SJ
    Obregon, RG
    Nelson, RC
    Simon, HE
    Schmiedl, UP
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04): : 596 - 602
  • [9] Comparison of single-breath-hold fast spin-echo sequences with routine non-breath-hold techniques: Application to MRI of renal masses
    Melki, PS
    Argaud, C
    Suminski, M
    Helenon, O
    Belin, X
    Millet, P
    Chretien, Y
    Zannoli, G
    Moreau, JF
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04): : 608 - 614
  • [10] Pulmonary regurgitant fraction is lower by expiratory breath-hold velocity mapping than by inspiratory or non-breath-hold
    Johansson, B.
    Babu-Narayan, S. V.
    Kilner, P. J.
    EUROPEAN HEART JOURNAL, 2005, 26 : 88 - 88