T2 weighted liver Magnetic Resonance imaging using functional residual capacity breath-hold with multi breath-hold

被引:0
|
作者
Tabuchi, A. [1 ,2 ]
Katsuda, T. [3 ]
Gotanda, R. [1 ]
Gotanda, T. [1 ]
Yamamoto, K. [1 ,4 ]
Mitani, M. [2 ]
Takeda, Y. [1 ]
机构
[1] Okayama Univ, Grad Sch Hlth Sci, 2-5-1 Shikata Cho, Okayama 7008530, Japan
[2] Kawasaki Med Sch Kawasaki Hosp, Okayama, Japan
[3] Himeji Dokkyo UNiv, Fac High Care Sci, Himeji, Hyogo, Japan
[4] Osaka Canc Prevent & Detect Ctr, Osaka, Japan
关键词
T2 weighted MR imaging; Functional Residual Capacity (FRC); reproducibility; high-resolution; TURBO-SPIN-ECHO; SEQUENCES;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: During acquisition of rapid high resolution (HR) T2 weighted (T2W) liver magnetic resonance (MR) images using a 1.0-Tesla (T) scanner, the liver is segmented into odd and even sections that are acquired at two different times using the multi-breath-hold (MBH) strategy. Misalignment between the two breath-hold (B-H) images may result in the occurrence of a blind area and a decrease in diagnostic accuracy. Here, a functional residual capacity (FRC) B-H method was developed to overcome this problem. Material and methods: Twenty-five volunteers were enrolled. The sagittal images were reconstructed from whole liver transverse images. The misalignments of the abdominal wall were measured in the anterior-posterior (AP) direction and were compared between each two B-H phases, maximum inspiration, maximum expiration, voluntary expiration and FRC using one-way repeated measures ANOVA. Differences between groups were compared using the t-test for multigroup comparisons. In addition, qualitative analysis of misalignment was performed between VE and FRC in 52 clinical patients and the chi(2) test was performed. Results: Misalignment of the liver position using FRC was significantly smaller than the other B-H methods (p < 0.05). Significant differences between the VE B-H and FRC B-H were also observed in the qualitative analysis (p < 0.05).
引用
收藏
页码:1598 / 1602
页数:5
相关论文
共 50 条
  • [21] Magnetic resonance coronary angiography: Comparison between respiratory gated and breath-hold imaging
    Regenfus, M
    Ropers, D
    Achenbach, S
    Kessler, W
    Laub, G
    Daniel, WG
    Moshage, W
    CIRCULATION, 2000, 102 (18) : 459 - 459
  • [22] Magnetic resonance coronary angiography: comparison between respiratory gated and breath-hold imaging
    Regenfus, M
    Ropers, D
    Achenbach, S
    Kessler, W
    Daniel, WG
    Laub, G
    Moshage, W
    EUROPEAN HEART JOURNAL, 2000, 21 : 565 - 565
  • [23] Hyperacute brain magnetic resonance imaging of decompression illness in a commercial breath-hold diver
    Kohshi, Kiyotaka
    Morimatsu, Yoshitaka
    Tamaki, Hideki
    Ishitake, Tatsuya
    Denoble, Petar J.
    CLINICAL CASE REPORTS, 2020, 8 (07): : 1195 - 1198
  • [24] Detection of pulmonary nodules with breath-hold magnetic resonance imaging in comparison with computed tomography
    Schäfer, JF
    Vollmar, J
    Schick, F
    Seemann, MD
    Kamm, P
    Erdtmann, B
    Claussen, CD
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (01): : 41 - 49
  • [25] Assessment of coronary bypass patency with breath-hold magnetic resonance angiography
    Ambrosi, P
    Gelisse, R
    Bruneau, P
    Habib, G
    Bretelle, C
    Luccioni, R
    Bernard, PJ
    PRESSE MEDICALE, 1996, 25 (38): : 1873 - 1875
  • [26] Breath-hold magnetic resonance cholangiopancreatography in the evaluation of malignant pancreaticobiliary obstruction
    Schwartz, LH
    Lefkowitz, RA
    Panicek, DM
    Coakley, FV
    Jarnagin, W
    Dematteo, R
    Fong, YM
    Blumgart, L
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 (03) : 307 - 314
  • [27] Application of deep learning techniques for breath-hold, high-precision T2-weighted magnetic resonance imaging of the abdomen
    Tanabe, Masahiro
    Kawano, Yosuke
    Ihara, Kenichiro
    Miyoshi, Keisuke
    Ishii, Jo
    Nomura, Kanako
    Morooka, Ryoko
    Higashi, Mayumi
    Ito, Katsuyoshi
    ABDOMINAL RADIOLOGY, 2024, : 2312 - 2320
  • [28] MULTISECTION FLASH - METHOD FOR BREATH-HOLD MR IMAGING OF THE ENTIRE LIVER
    TAUPITZ, M
    HAMM, B
    SPEIDEL, A
    DEIMLING, M
    BRANDING, G
    WOLF, KJ
    RADIOLOGY, 1992, 183 (01) : 73 - 79
  • [29] Pancreatic adenocarcinoma: a pilot study of quantitative perfusion and diffusion-weighted breath-hold magnetic resonance imaging
    Hyunki Kim
    Pablo J. Arnoletti
    John Christein
    Martin J. Heslin
    James A. Posey III
    Amol Pednekar
    T. Mark Beasley
    Desiree E. Morgan
    Abdominal Imaging, 2014, 39 : 744 - 752
  • [30] LIVER-BUDA-SAGE: SIMULTANEOUS WHOLE LIVER T2 AND T*2 MAPPING IN ONE BREATH-HOLD
    Zhang, Zijing
    Ye, Huihui
    Li, Maosen
    Liu, Huafeng
    Bilgic, Berkin
    2022 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (IEEE ISBI 2022), 2022,